Inspections for the day of: Monday, October 12, 2015.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-00694 ELE-Aging Inspection10/12/201510/12/201510/12/2015 2:23:06 PM DONE
Called contractor. No outstanding issues with service ok final.
ELE13-00694 Final10/12/201510/12/201510/12/2015 2:22:58 PMPPASS
Final ok
ELE13-01274 ELE-Aging Inspection10/12/201510/12/201510/12/2015 2:08:53 PM DONE
Called contractor ok to final permit no out standing issues.
ELE13-01274 Final10/12/201510/12/201510/12/2015 1:19:28 PMPPASS
No out standing issues with service repair. Final ok
ELE15-03195 Final10/9/201510/12/201510/12/2015 1:06:03 PMAPASS
Ruben Phone #: ###-#### No additional wiring associated with this permit. Service only. Final ok
ELE15-03195 Electrical Rough-In10/12/201510/12/201510/12/2015 12:51:00 PMPPASS
Ruben Phone #: ###-#### Underground to mobilehome rough in ok cover
ELE15-03195 Permanent Service10/12/201510/12/201510/12/2015 12:50:11 PMPPASS
Ruben Phone #: ###-#### p/s o/h n ok
ELE15-03271 Electrical Rough-In10/9/201510/12/201510/12/2015 12:12:43 PMAPASS
Vonn Phone #: ###-#### New service rough in ok
ELE15-03271 Permanent Service10/12/201510/12/201510/12/2015 12:12:04 PMPPASS
Vonn Phone #: ###-####
p/s o/h rec ok
ELE15-03271 Conference10/12/201510/12/201510/12/2015 12:11:23 PMPDONE
Vonn Phone #: ###-#### Discussed using old panel location in closet as junction point to connect to existing wiring. No wiring to be added.
ELE15-03242 Electrical Rough-In10/12/201510/12/201510/12/2015 10:54:21 AMPCANC
Underground inspection only. Please contact Jerry ###-#### with any questions. Phone #: ###-#### >> Inspection requested via web by Tracy Robertson Inspection cancelled from web by: Tracy Robertson
ELE15-02660 Final10/9/201510/12/201510/12/2015 10:14:48 AMAFAIL
call ###-#### for access Phone #: ###-#### Inspection requested via web by David Nelson 110.26- work space for panel in pantry shall have a minimum of 30" wide floor to ceiling.
BCC 4-05-32- No violation shall be retained. 314.20- Boxes located in walls with wood panels shall have a spark ring installed.
210.8- Receptacle outlets located with in 6' of a sink shall have GFCI protection.
314.23(A)- Meter enclosure shall be securely mounted in place.
334.30- NM cable in island shall be secured in place
ELE15-03226 Rough-In Permanent Service10/9/201510/12/201510/12/2015 10:14:42 AMAPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk Both units Rough in ok cover p/s u/g n ok
ELE15-03226 Rough-In Permanent Service10/12/201510/12/201510/12/2015 9:29:10 AMPPASS
Rough in ok cover p/s u/g n ok
ELE15-03148 Rough-In Permanent Service10/12/201510/12/201510/12/2015 8:44:40 AMAPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov Rough in ok cover p/s u/g n ok