Inspections for the day of: Wednesday, October 12, 2016.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC15-05828 Mec-Aging Inspection10/12/201610/12/201610/12/2016 4:41:36 PM PEND
MEC15-05797 Mec-Aging Inspection10/12/201610/12/201610/12/2016 4:40:42 PM CANC
MEC15-05797 DOC - Permit Expired10/12/201610/12/201610/12/2016 4:40:33 PMPPASS
MEC16-04527 Final10/12/201610/12/201610/12/2016 4:39:40 PMPPASS
Units will be ready to inspect after 2pm Inspection requested via web by Margie Rowe
MEC16-04344 Pressure Test10/10/201610/12/201610/12/2016 4:11:49 PMPPASS
Please call Daryl with any questions. Phone #: ###-#### Inspection requested via web by Diane Day
20lb gas
MEC16-04344 Rough-in10/10/201610/12/201610/12/2016 4:11:19 PMPPASS
Please call Daryl with any questions. Phone #: ###-#### Inspection requested via web by Diane Day
condensate needs to be glued for final
MEC16-01431 Rough-in10/12/201610/12/201610/12/2016 3:35:09 PMPFAIL
Victoria// insp. for fireplace//please call ahead Phone #: ###-####
gas piping needs to be installed per manufactures instalation instructions and with approved products,
linesets need nail plates
flex tube isnot an approved product for in wall condensate piping
need fire caulk on fireplace draft stop
MEC16-01431 Pressure Test10/12/201610/12/201610/12/2016 3:32:29 PMPFAIL
Victoria// please call ahead Phone #: ###-####
need to make corrections and retest
MEC16-03173 Rough-in10/11/201610/12/201610/12/2016 3:07:27 PMAPART
Request inspection for radiation dampers for 2nd floor bathroom. Please contact job lead, Chris ###-#### with any questions or concerns. Phone #: ###-#### Inspection requested via web by Heather Gransbery
2nd floor bathrooms ok to cover, radiant dampers still need to be installed
MEC16-03246 Final10/12/201610/12/201610/12/2016 2:46:23 PMPFAIL
Access # 1225 Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN
2nd condensate need to go to a conspicouis location, both units need this
MEC16-04400 Pressure Test10/12/201610/12/201610/12/2016 2:42:10 PMPPASS
Please call Mike at ###-#### prior to inspection. He will have to go and meet you there Phone #: ###-#### Inspection requested via web by Tami Kelly
5lb flue
MEC16-04400 Final10/12/201610/12/201610/12/2016 2:41:46 PMPPASS
Please call Mike at ###-#### prior to inspection. He will have to go and meet you there Phone #: ###-#### Inspection requested via web by Tami Kelly
MEC15-04633 Final10/11/201610/12/201610/12/2016 2:19:21 PMAPART
Partial Final for 1st Floor and the Basement, call Brad. Thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum
temp c.o. garage and 1st floor stack 2 And 3,

1-4 annex trim
MEC16-01742 Final10/12/201610/12/201610/12/2016 12:21:07 PMPPASS
MEC16-04270 Rough-in10/11/201610/12/201610/12/2016 11:49:50 AMAPASS
Code for lock box 0516 Phone #: ###-#### Inspection requested via web by Angie Thome
MEC16-04270 Pressure Test10/11/201610/12/201610/12/2016 11:49:32 AMAPASS
Phone #: ###-#### Inspection requested via web by Angie Thome
60lb gas
MEC16-04533 Pressure Test10/11/201610/12/201610/12/2016 11:37:38 AMANR
Please Call Greg before you come and we are requesting late am please.
Greg ###-#### Phone #: ###-#### Inspection requested via web by Greg Mendiola
MEC16-03241 Final10/11/201610/12/201610/12/2016 10:50:47 AMAPASS
Phone #: ###-#### Inspection requested via web by Krista Boss
MEC16-03868 Final10/11/201610/12/201610/12/2016 10:41:32 AMAPASS
please contact installer for access Phone #: ###-#### Inspection requested via web by Marisa Hone
MEC16-04400 Final10/12/201610/12/201610/12/2016 8:34:37 AMPCANC
Please call Mike at ###-#### prior to inspection. He will have to go and meet you there Phone #: ###-#### >> Inspection requested via web by Tami Kelly Inspection cancelled from web by: Tami Kelly