Inspections for the day of: Friday, October 13, 2006.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorForrest France
TitleFIRE INSPECTOR
Phone #794-1981
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
FIR06-00512 INSP-Final Inspection10/13/200610/13/200610/15/2006 6:41:08 PMPNR
rod; Phone #: ###-#### Internet Inspection Request from: Darla Downs
FIR06-00441 INSP-Sprinkler Rough-in/Hydro10/12/200610/13/200610/15/2006 6:40:46 PMPNR
Scheduled by a contractor via Hello! on 10/12/2006 at 1:54:43 PM. Contact: ###-####.
FIR06-00608 INSP-Conference10/12/200610/13/200610/13/2006 3:20:54 PMPCANC
FIR06-00608 INSP-Final Inspection10/13/200610/13/200610/13/2006 3:16:31 PMPNR
Project is not ready for inspection.
FIR06-00511 INSP-Final Inspection10/13/200610/13/200610/13/2006 2:47:29 PMPFAIL
Heads in the file storage room are overspaced, two heads at the reception area on the north side are overspaced off an adjacent wall, one head in a south office as marked on plans needs to be relocated for proper coverage, inspected relocated heads outside the scope of work in the elevator lobby and 1hr corridors, some field modifications have been made which are not included on approved plans.
FIR06-00660 INSP-Sprinkler Rough-in/Hydro10/12/200610/13/200610/13/2006 2:42:27 PMPFAIL
UG fire supply line does not meet requirements of NFPA 13 for the min. depth of bury. The pipe as installed is approx 10" to 12" too shallow.
FIR06-00691 INSP-Sprinkler Rough-in/Hydro10/12/200610/13/200610/13/2006 12:40:07 PMAPART
OH rough-in at the drop ceiling areas is good for cover.
BLD05-02015 FIRE-Final Inspection10/12/200610/13/200610/13/2006 11:56:01 AMAPASS
Corrections have been verified, fire life safety inspection passed. Note, one section of curb missing fire lane paint marking to be completed per contractor, will verify next week for compliance.
FIR06-00064 INSP-Final Inspection10/13/200610/13/200610/13/2006 11:52:22 AMPPASS
Fire alarm permit finaled.
FIR05-00901 INSP-Final Inspection10/12/200610/13/200610/13/2006 11:51:42 AMAPASS
Required corrections have been made, fire sprinkler permit finaled.
FIR06-00329 INSP-Final Inspection10/12/200610/13/200610/13/2006 11:50:15 AMAPASS
Fire alarm work passed inspection, permit finaled.
BLD06-01980 FIRE-Final Inspection10/13/200610/13/200610/13/2006 10:34:55 AMPCANC
tucker; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Inspection cancelled from web by: Patricia Smith
FIR06-00743 INSP-Final Inspection10/13/200610/13/200610/13/2006 10:03:39 AMPCANC
Can we get this late in the day. Richard is the contact ####-####. Thanks; Phone #: ###-#### Internet Inspection Request from: Trent Bice Inspection cancelled from web by: Trent Bice
FIR06-00441 INSP-Sprinkler Rough-in/Hydro10/12/200610/13/200610/12/2006 1:57:47 PMACANC
Scheduled by a contractor via Hello! on 10/12/2006 at 1:49:39 PM. Contact: ###-####. Disp set to [CANC] by a contractor via Hello! on Oct 12 2006 1:57PM.