MEC17-04578
| Final | 10/13/2017 | 10/13/2017 | 10/13/2017 3:04:32 PM | P | NR |
|
|
2:30pmish please call Craig ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- need all installaion complete to final out- talked with Craig about this- need high low combustion air in basement- need power to A/C installed
|
MEC17-04578
| Pressure Test | 10/13/2017 | 10/13/2017 | 10/13/2017 3:00:46 PM | P | PASS |
|
|
2:30pmish please call Craig ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- 5lb flue pass
|
MEC17-04521
| Pressure Test | 10/10/2017 | 10/13/2017 | 10/13/2017 2:22:52 PM | P | PASS |
|
|
Installer Al ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- 20lb gas pass- need to seal gas penetration in garage thru sheetrock- need to provide 2 CO detectors 1 upstairs and 1 downstairs by final
|
MEC17-03657
| Final | 10/13/2017 | 10/13/2017 | 10/13/2017 1:26:51 PM | P | PASS |
|
|
mechanical fireplace final inspection Phone #: ###-#### Inspection requested via web by Dan Otero
|
MEC17-03057
| Final | 10/12/2017 | 10/13/2017 | 10/13/2017 11:48:36 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jasmin Godina
|
MEC17-04087
| Final | 10/12/2017 | 10/13/2017 | 10/13/2017 11:16:16 AM | A | CANC |
|
|
Contact: Bill Hunt
Request partial final on the first floor for Friday morning. Phone #: ###-#### Inspection requested via web by Melissa Kaae- should have been rough in inspection not final
|
MEC17-04087
| Rough-in | 10/13/2017 | 10/13/2017 | 10/13/2017 11:15:51 AM | P | PASS |
|
|
Contact: Bill Hunt
Request partial final on the first floor for Friday morning. Phone #: ###-#### Inspection requested via web by Melissa Kaae- seal ok- insulation ok- registers ok- north side from east to west excluding offices ok for ceiling tiles
|
MEC17-04255
| Rough-in | 10/12/2017 | 10/13/2017 | 10/13/2017 10:55:58 AM | A | PASS |
|
|
Jason 208-.###-#### Inspection requested via web by Jason Robinson- fireplace rough in ok
|
MEC17-04255
| Pressure Test | 10/12/2017 | 10/13/2017 | 10/13/2017 10:55:29 AM | A | PASS |
|
|
Jason 208-.###-#### Inspection requested via web by Jason Robinson- 20lb gas pass
|
MEC16-05523
| Final | 10/12/2017 | 10/13/2017 | 10/13/2017 10:31:41 AM | A | NH |
|
|
Please Call 30 minutes prior to arrival. She must be gone by 11 am. Mary Kay ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby- called no answer- stopped by no one home- left notice on front door
|
MEC17-02024
| Final | 10/12/2017 | 10/13/2017 | 10/13/2017 9:58:49 AM | A | PASS |
|
|
thank you Phone #: ###-#### Inspection requested via web by Aaron Alandt
|
MEC17-02628
| Final | 10/12/2017 | 10/13/2017 | 10/13/2017 9:52:16 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka
|
MEC17-04517
| Final | 10/12/2017 | 10/13/2017 | 10/13/2017 9:20:28 AM | A | FAIL |
|
|
Please call Roger Aguilar at ###-#### about 30 - 60 minutes prior to inspection Phone #: ###-#### Inspection requested via web by Mary LaFayetteG2427.3.4 2012 IRC states no venting shall extend into or pass through any fabricated air duct or furnace plenum-
|
MEC17-03549
| Pressure Test | 10/13/2017 | 10/13/2017 | 10/13/2017 8:59:35 AM | P | CANC |
|
|
Field super: Daryl Thomas Phone #: ###-#### >> Inspection requested via web by Lisa Whitney Inspection cancelled from web by: Lisa Whitney
|
MEC17-03549
| Rough-in | 10/13/2017 | 10/13/2017 | 10/13/2017 8:59:33 AM | P | CANC |
|
|
Field super: Daryl Thomas Phone #: ###-#### >> Inspection requested via web by Lisa Whitney Inspection cancelled from web by: Lisa Whitney
|
MEC17-04538
| Final | 10/11/2017 | 10/13/2017 | 10/13/2017 8:49:39 AM | A | FAIL |
|
|
Call Oliver Steiger (Homeowner) Phone #: ###-#### Inspection requested via web by Sheldon Lebow- appliance connectors can not penetrate thru appliance even with sleeve, needs to be hard pipe or approved method- need to remove face plate to be able to see install in chiminey
|
MEC17-04506
| Final | 10/9/2017 | 10/13/2017 | 10/12/2017 3:24:09 PM | P | CANC |
|
|
Hello! Please call Dwight @ ###-#### to confirm job is ready for inspection.
Thank you! Phone #: ###-#### >> Inspection requested via web by Rick Borg Inspection cancelled from web by: Rick Borg
|