PLM17-03869
| Water and/or Sewer | 10/12/2017 | 10/13/2017 | 10/13/2017 2:16:41 PM | P | PART |
|
|
partial water/sewer Phone #: ###-#### Inspection requested via web by Katherine Creekbaum. Water service and sewer ok to cover. No approved plans on the job. Spoke with the builder and explained they taking responsiblities for any changes required on the approved set. Grease trap needs 24 hour test.
|
PLM17-02643
| Groundwork | 10/13/2017 | 10/13/2017 | 10/13/2017 1:07:58 PM | P | FAIL |
|
|
Contact: Robert Church ###-#### Phone #: ###-#### Inspection requested via web by Brent Lacy. Building drain and sewer are backgrading 1/2" per foot at the connection. Expose sewer and building drain to verify grade. 2. Add the addition of the backwater valve value to the permit.
|
PLM17-03942
| Final | 10/13/2017 | 10/13/2017 | 10/13/2017 12:55:07 PM | P | PASS |
|
|
For questions call James at number provided. Phone #: ###-#### Inspection requested via web by Ben Davis
|
PLM17-03977
| Final | 10/13/2017 | 10/13/2017 | 10/13/2017 12:44:39 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Vaughn Carlson
|
PLM16-01058
| Sprinkler (Final) | 10/13/2017 | 10/13/2017 | 10/13/2017 11:52:04 AM | P | PASS |
|
|
|
PLM17-03961
| Final | 10/12/2017 | 10/13/2017 | 10/13/2017 11:11:16 AM | A | NH |
|
|
Garage Code 1977. Customer will not be home. Permission to enter through the garage. See Garage code above. Call Bill with any questions. Phone #: ###-#### Inspection requested .. via web by Ben Davis. Will reschedule and meet on the job for access
|
PLM17-03936
| Final | 10/11/2017 | 10/13/2017 | 10/13/2017 11:03:17 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by John Hensley
|
PLM17-03937
| Water Heater Final | 10/11/2017 | 10/13/2017 | 10/13/2017 10:54:32 AM | A | PASS |
|
|
Please call John prior to arrival at ###-####. thank you! Phone #: ###-#### Inspection requested via web by Maira Napoles
|
PLM17-02434
| Final | 10/12/2017 | 10/13/2017 | 10/13/2017 10:39:44 AM | A | PASS |
|
|
BRECK IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
|
PLM17-03803
| Water and/or Sewer | 10/13/2017 | 10/13/2017 | 10/13/2017 10:24:57 AM | P | PASS |
|
|
Manufactured Home sewer and water hook up. Failed previously because it needed a backflow inspection. That is complete now. Thanks!! Phone #: ###-#### Inspection requested via web by Ashleigh Meligan
|
PLM17-03803
| DOC - Permit Finaled | 10/13/2017 | 10/13/2017 | 10/13/2017 10:24:32 AM | P | PASS |
|
|
|
PLM17-03856
| Final | 10/10/2017 | 10/13/2017 | 10/13/2017 10:13:15 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Marisa Hone. Support the 4" flue from the water heater to the vertical connection. Reschedule
|
PLM17-03963
| Final | 10/12/2017 | 10/13/2017 | 10/13/2017 9:16:12 AM | A | CANC |
|
|
Ask for Angel onsite, Mr. Rooter technician Shane Merkley will not be onsite. Work has was completed 5/16-5/17/17 between two Mr. Rooter invoices, 58073361 and 58049560. The wall where work was done has been back filled, but Mr. Rooter has picture evidence of work before, while, and after it was done that can be emailed per inspector request. Phone #: ###-#### Inspection requested via web by Shane Loar. Rescheduled for site meeting
|
PLM17-03944
| Final | 10/12/2017 | 10/13/2017 | 10/13/2017 8:52:33 AM | A | PASS |
|
|
Ben Taylor Phone #: ###-####
|
PLM17-03883
| Water Heater Final | 10/10/2017 | 10/13/2017 | 10/11/2017 9:13:40 AM | A | CANC |
|
|
Please call Lynette prior to arrival at ###-####. Phone #: ###-#### >> Inspection requested via web by Maira Napoles Inspection cancelled from web by: Maira Napoles
|