ELE07-00490
| ELE-Aging Inspection | 10/14/2008 | 10/14/2008 | 10/17/2008 3:16:46 PM | | DONE |
|
|
see final, no esc this project
|
ELE07-00524
| ELE-Aging Inspection | 10/14/2008 | 10/14/2008 | 10/15/2008 9:40:10 AM | | DONE |
|
|
see final, no esc this project
|
ELE08-02759
| Final | 10/14/2008 | 10/14/2008 | 10/14/2008 4:44:16 PM | P | PASS |
|
|
gene Phone #: ###-#### see response, computer glitch, but ok to final, no esc this project
|
MIS08-00142
| ELE-Conference | 10/14/2008 | 10/14/2008 | 10/14/2008 4:42:41 PM | P | DONE |
|
|
horace - ###-#### - please call 1/2 hr prior - after 2:00 please Met real estate man, and 324 and reviewed house. Many violations are present. Most of the following comments appear to be installed after the house was built. Exposed nm cable at front porch area, garage built in closet and main part of garage, as well as back porch area. Outside boxes for receptacle and switches are not water or wet proof, nor are there wet use type covers installed, outside lighting fixtures are not approved for wet locations. Garage receptacles are not gfci protected, bath receptacles are not gfci protected. So cord for fan penetrates metal grill, no abrasion protection, not approved wiring method. Hot tub doesn't have approved listing by testing laboratory, installation of hot tub not legal or inspected. Out-building was not done per code, and it must be determined what the service is and how installed as well as ampacity, u/g going to building needs inspected to determine depth, grounding must be verified, lighting and power distribution must be done per code. Outside of building has violations as well as inside. U/g to outside lighting must be verified front and back of house. The fireplace insert is not listed or legal for the installation.
|
ESC07-01432
| General Inspection | 10/14/2008 | 10/14/2008 | 10/14/2008 3:48:02 PM | P | PASS |
|
|
looked ok
|
ESC07-00733
| General Inspection | 10/14/2008 | 10/14/2008 | 10/14/2008 3:47:08 PM | P | PASS |
|
|
looked ok
|
ESC08-00223
| General Inspection | 10/14/2008 | 10/14/2008 | 10/14/2008 3:46:16 PM | A | PASS |
|
|
looked ok
|
ELE08-02759
| Final | 10/14/2008 | 10/14/2008 | 10/14/2008 3:44:58 PM | P | PASS |
|
|
ok to final, corrections made, no esc this project
|
ELE08-02797
| Permanent Service | 10/14/2008 | 10/14/2008 | 10/14/2008 2:47:04 PM | P | PASS |
|
|
p/s u/g rec ok, no esc this project
|
ELE07-02082
| Temporary Service | 10/14/2008 | 10/14/2008 | 10/14/2008 1:56:22 PM | P | PASS |
|
|
steve Phone #: ###-#### t/s u/g n ok
|
ELE08-02771
| Rough-In Permanent Service | 10/14/2008 | 10/14/2008 | 10/14/2008 1:19:30 PM | P | FAIL |
|
|
ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten called contractor to provide clearance, NEC 230. 24(A), provide abrasion protection, NEC 312.5, close breaker opening, 110.!2(A)
|
ELE08-02423
| Electrical Rough-In | 10/13/2008 | 10/14/2008 | 10/14/2008 12:28:19 PM | A | PASS |
|
|
JASON BLDG 3 L2 UNIT D - EAST & D - WEST. Phone #: ###-#### Internet Inspection Request from: Sean DeLacy 2 units, ric ok, anop
|
ELE08-02737
| Final | 10/13/2008 | 10/14/2008 | 10/14/2008 10:29:09 AM | A | PASS |
|
|
Contact: Darby Talbot Phone #: ###-#### Internet Inspection Request from: Deb Gooden saw labelling didn't see before, ok to final, no esc this project
|
ELE08-02759
| Conference | 10/13/2008 | 10/14/2008 | 10/14/2008 9:54:02 AM | A | DONE |
|
|
jean Phone #: ###-#### looked at open walls, need to replace box, 1 1/4", add gfci to garage receptacle,repair mouse damaged jacketing, add arc-fault for bedroom, electrician will fix and call for final
|
ELE08-02009
| Final | 10/13/2008 | 10/14/2008 | 10/14/2008 9:15:44 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Bryan McLaughlin ok to final, signed occupancy card, no esc this project
|
ELE08-02773
| Final | 10/13/2008 | 10/14/2008 | 10/14/2008 8:37:32 AM | A | PASS |
|
|
jesse Phone #: ###-#### ok to final, no esc this project
|
ELE08-02773
| Permanent Service | 10/14/2008 | 10/14/2008 | 10/14/2008 8:25:45 AM | A | PASS |
|
|
jesse Phone #: ###-#### p/s o/h rec ok, no esc this project
|
ELE08-00812
| Final | 10/13/2008 | 10/14/2008 | 10/14/2008 8:14:10 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Bryan McLaughlin ok to final no card required to sign
|
ELE08-02770
| Electrical Rough-In | 10/14/2008 | 10/14/2008 | 10/14/2008 12:00:00 AM | P | CANC |
|
|
Phone #: ###-#### Internet Inspection Request from: Andy Derrick Per Andy cancel this inspection and he will set it up for the next day///dld
|