Inspections for the day of: Tuesday, October 14, 2014.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-02683 Final10/14/201410/14/201410/14/2014 2:05:59 PMPPASS
Back Door Is Open Thank You And Have A Great Day! Phone #: ###-#### Inspection requested via web by jason shifflett Final ok
ELE14-02846 Electrical Rough-In10/14/201410/14/201410/14/2014 1:55:10 PMPPASS
Phone #: ###-#### Inspection requested via web by Mark Estep up bed and bath, closet, sitting room rough in ok cover
ELE11-02772 ELE-Aging Inspection10/14/201410/14/201410/14/2014 1:33:46 PM DONE
Still under construction
ELE14-01948 Electrical Rough-In10/14/201410/14/201410/14/2014 12:51:45 PMPFAIL
###-#### Concrete encased rough in. 250.52(A)(3)- South east service, concrete encased will not work do to rebar and 20" of wire located on top of plastic moisture barrier, not tied to footing or foundation rebar. It shall be in direct contact with earth.
ELE14-02842 Rough-In Permanent Service10/13/201410/14/201410/14/2014 12:17:35 PMPFAIL
Phone #: ###-#### Inspection requested via web by Neal Rumsey 300.4- NM cable shall be installed where not subject to physical damage. Upstairs by return air.
314.3- NM cable shall terminate in a box, laundry rm and out lights
ELE14-01948 Electrical Rough-In10/13/201410/14/201410/14/2014 10:39:09 AMANR
Contact: Jeremy Thornock. Ufer inspection please Phone #: ###-#### Inspection requested via web by Deb Gooden Wire removed no rebar in place
ELE14-02836 Final10/13/201410/14/201410/14/2014 10:18:29 AMAFAIL
Jason Gaythwaite is our journeyman Contact Phone #: ###-#### Inspection requested via web by Kelly Felin 210.63- A 15 or 20 amp 120 volt receptical outlet shall be installed within 25' of AC unit.
ELE14-02841 Temporary Service10/13/201410/14/201410/14/2014 10:03:04 AMAPASS
please call me if their is an issue. thank you! Phone #: ###-#### Inspection requested via web by Robert Schroder t/s o/h n ok
ELE14-01848 Final10/13/201410/14/201410/14/2014 9:52:08 AMAPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Final ok
ELE14-02698 Electrical Rough-In10/13/201410/14/201410/14/2014 9:21:53 AMAPASS
Cover for walls, and bathroom ceiling Phone #: ###-#### Inspection requested via web by Stan Woodward Rough in ok cover
ELE14-01556 Conference10/14/201410/14/201410/14/2014 9:07:30 AMPDONE
Ladder being added to north side of pool after pool shell completely enclosed check bonding for this ladder for final
ELE14-02233 Permanent Service10/13/201410/14/201410/14/2014 9:04:57 AMAPASS
Phone #: ###-#### Inspection requested via web by Kevin Burke p/s u/g n ok
ELE14-01526 Conference10/13/201410/14/201410/13/2014 2:24:41 PMADONE
Richard Phone #: ###-#### Discussed the attachment of flexible cord to hoist to avoid physical damage.