Inspections for the day of: Monday, October 15, 2018.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-04023 Rough-in10/12/201810/15/201810/15/2018 4:17:16 PMACANC
Phone #: ###-#### Inspection requested via web by Amanda Farnsworth- called number on inspection notes and no one answered-
MEC18-02583 Final10/12/201810/15/201810/15/2018 3:14:45 PMPNH
Please call Maddie when on way ###-#### Phone #: ###-#### Inspection requested via web by Carol Clark- called maddie no anwser and no access code to get through gate
MEC18-04887 Final10/15/201810/15/201810/15/2018 2:49:11 PMPPASS
Phone #: ###-#### Inspection requested via web by Marisa Hone- final ok
MEC18-04946 Final10/12/201810/15/201810/15/2018 2:46:02 PMPPASS
late pm inspection if possible please
installer: archie ###-####
thank you Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace ac coil co ok
MEC18-04889 Rough-in10/15/201810/15/201810/15/2018 2:17:11 PMPPART
Joe Phone #: ###-####- crawl needs to still be finished- need to check equipment at final- fresh air needs to terminate side not through the roof
MEC18-04886 Rough-in10/15/201810/15/201810/15/2018 2:15:54 PMPPART
Joe Phone #: ###-####- crawl needs finished- need to check equipment at final- fresh air needs to terminate side wall not through the roof-
MEC18-04889 Pressure Test10/15/201810/15/201810/15/2018 2:09:32 PMPPASS
Joe Phone #: ###-####- 20lb gas ok 5lb flue ok
MEC18-04886 Pressure Test10/15/201810/15/201810/15/2018 2:08:30 PMPPASS
Joe Phone #: ###-####- 20lb gas ok 5lb flue ok
MEC18-04955 Rough-in10/15/201810/15/201810/15/2018 1:34:17 PMPFAIL
OPEN JOB SITE. WE RAN LINESETS THRU BARE WALLS AND WANT TO GET ROUGH IN INSPECTED BEFORE THOSE WALLS ARE CLOSED IN. MY NAME IS STEVE DALE WITH DIAMOND AND I LEFT MY OFFICE NUMBER IF ANY QUESTIONS OR CONCERNS Phone #: ###-#### Inspection requested via web by Rick Montgomery
-each head unit has arma flex rips that need repaired indoors and outdoors- condensate needs to run all the way down into the drain pipe in the washer box- one condensate line in the wall needs grade to drain- dryer vent next to indoor unit needs repaired, it was damaged when hit by a hole saw cutting a hole in the wall for a lineset
MEC18-03276 Final10/15/201810/15/201810/15/2018 1:29:41 PMPFAIL
Marco Phone #: ###-####
- need air balance report on site and air balancer certification is expired 2017
MEC18-03275 Final10/15/201810/15/201810/15/2018 1:29:17 PMPFAIL
Marco Phone #: ###-####
-need to install drip leg after gas shut off at furnace- need air balance report on site and air balancer certification is expired 2017
MEC18-02880 Final10/15/201810/15/201810/15/2018 1:28:54 PMAPASS
Key under flower pot next to front door.
Kitchen remodel Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek
MEC18-04917 Final10/15/201810/15/201810/15/2018 1:24:18 PMPPASS
I sent you pictures. Phone #: ###-#### Inspection requested via web by Mary LaFayette

MEC18-04835 Rough-in10/12/201810/15/201810/15/2018 10:57:01 AMAFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves- gas line penetration needs inert tape- arma flex has rips in the wall- fresh air flex is being smashed by plumbing- supply boot above front porch needs to be insulated- supply boot in living room needs to be sealed- supply duct in wall at the stair case needs a nail plate protection
MEC18-04835 Pressure Test10/12/201810/15/201810/15/2018 10:49:35 AMAPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas ok- 5lb flue ok
MEC18-02605 Rough-in10/12/201810/15/201810/15/2018 9:31:39 AMAPASS
cover for unit 141,142,140,101,102 Phone #: ###-#### Inspection requested via web by Nicholas Paige- R/I ok
MEC18-04411 Rough-in10/12/201810/15/201810/15/2018 9:00:07 AMAPASS
Bill Phone #: ###-####- range hood vent R/I ok
MEC18-04511 Final10/15/201810/15/201810/15/2018 8:19:36 AMAPASS
Sent you pictures this AM Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace ac coil co ok
MEC18-01415 Final10/12/201810/15/201810/12/2018 5:03:10 PMACANC
RICK ###-#### Phone #: ###-#### >> Inspection requested via web by Mike Almanza Inspection cancelled from web by: Mike Almanza