ELE19-03258
| Electrical Rough-In | 10/10/2019 | 10/15/2019 | 10/15/2019 1:56:39 PM | P | CANC |
|
|
Pre-release inspection in order to allow ID Power to reconnect service Phone #: ###-#### Inspection requested via web by BRS Permitting..
wrong inspection...needed permanent service inspection
|
ELE19-03258
| Permanent Service | 10/15/2019 | 10/15/2019 | 10/15/2019 1:55:37 PM | P | PASS |
|
|
Pre-release inspection in order to allow ID Power to reconnect service Phone #: ###-#### Inspection requested via web by BRS Permitting.. p/s u/g reconnect ok
|
ELE19-01954
| Final | 10/15/2019 | 10/15/2019 | 10/15/2019 1:32:09 PM | P | PASS |
|
|
call half hour before // joe Phone #: ###-####...ok to final
|
ELE19-02689
| Electrical Rough-In | 10/15/2019 | 10/15/2019 | 10/15/2019 12:48:38 PM | P | CANC |
|
|
I''m home today so just stop by. Please come between 3 and 4 though. Thanks! Phone #: ###-#### Inspection requested via web by Brad Downs...spoke with permit holder...ok to reschedule for next day first thing 8AM
|
ELE19-01739
| Electrical Rough-In | 10/15/2019 | 10/15/2019 | 10/15/2019 12:25:49 PM | P | FAIL |
|
|
trench depth for monument light direct bury wire Phone #: ###-#### Inspection requested via web by David McClellan... 1) trench for UF wire needs verified to proper depth...installed without inspection...T300.5
|
ELE19-02902
| Electrical Rough-In | 10/15/2019 | 10/15/2019 | 10/15/2019 12:24:32 PM | P | FAIL |
|
|
trench depth for monument light direct bury wire Phone #: ###-#### Inspection requested via web by David McClellan... 1) UF wire needs trench to proper depth...T300.5
|
ELE19-03503
| Electrical Rough-In | 10/15/2019 | 10/15/2019 | 10/15/2019 12:23:01 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by David McClellan... 1) fireplace shall be installed for rough-in inspection 2) manufacturers rating on connector used at panel for branch circuits is rated for no more than 2 NM cables-RC50 3) Foyer wiring - 210.52(I)...3ft wall space needs outlet..2 places
|
ELE19-03828
| Final | 10/14/2019 | 10/15/2019 | 10/15/2019 10:41:19 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dean Gernaat...thank you..corrections made...ok to final
|
ELE19-03892
| Rough-In Permanent Service | 10/14/2019 | 10/15/2019 | 10/15/2019 10:24:20 AM | A | PASS |
|
|
Just west of Fairview/Five Mile intersection on the south side of Fairview. Phone #: ###-#### Inspection requested via web by Dan Jennings... rough ok to cover p/s u/g new ok
|
ELE19-03534
| Final | 10/14/2019 | 10/15/2019 | 10/15/2019 9:53:49 AM | A | PASS |
|
|
20A Circuit For Floor Heat In Master ; Guest Bathroom Phone #: ###-#### Inspection requested via web by Louis Keller...ok to final
|
ELE19-02845
| Final | 10/14/2019 | 10/15/2019 | 10/15/2019 9:25:50 AM | A | FAIL |
|
|
garage code 4141 Phone #: ###-#### Inspection requested via web by Emmet Bushman... 1) OCPD shall be no larger than required by nameplate rating on appliance,,oven 2) all appliances shall be operational.. disposal whip needs installed
|
ELE19-03752
| Electrical Rough-In | 10/15/2019 | 10/15/2019 | 10/15/2019 8:38:31 AM | A | PASS |
|
|
Underground electrical Inspection for satellite structure pour Contact Travis Hust Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek...ok to pour...base conduits and uffer ground in base
|