ELE06-02865
| Final | 10/12/2006 | 10/16/2006 | 10/16/2006 4:36:36 PM | P | PASS |
|
|
call Randy; Phone #: ###-#### Internet Inspection Request from: Loren Ramsey ok to final
|
ELE06-02863
| Final | 10/12/2006 | 10/16/2006 | 10/16/2006 3:57:27 PM | P | PASS |
|
|
call Randy; Phone #: ###-#### Internet Inspection Request from: Loren Ramsey ok to final
|
ELE06-03829
| Electrical Rough-In | 10/13/2006 | 10/16/2006 | 10/16/2006 3:25:42 PM | P | PASS |
|
|
Requesting an inspection to cover.; Phone #: ###-#### Internet Inspection Request from: Dan Hardisty walls only ok to cover
|
ELE06-02624
| ELE-Aging Inspection | 10/16/2006 | 10/16/2006 | 10/16/2006 2:53:04 PM | | DONE |
|
|
see rip
|
ELE06-02943
| Final | 10/16/2006 | 10/16/2006 | 10/16/2006 2:50:36 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson ok to final
|
ELE06-03834
| Electrical Rough-In | 10/16/2006 | 10/16/2006 | 10/16/2006 2:45:50 PM | P | PASS |
|
|
pat Note: garage; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles garage only ok to cover
|
ELE06-03475
| Conference | 10/13/2006 | 10/16/2006 | 10/16/2006 2:10:48 PM | P | DONE |
|
|
patrick; Phone #: ###-#### Internet Inspection Request from: Darla Downs reviewed service, gfci, cabling, disconnects, 1 1/4"
|
ELE06-03833
| Permanent Service | 10/16/2006 | 10/16/2006 | 10/16/2006 1:15:28 PM | P | CANC |
|
|
phil; Phone #: ###-#### Internet Inspection Request from: Patricia Smith wrong type insp, see ri
|
ELE06-03833
| Electrical Rough-In | 10/16/2006 | 10/16/2006 | 10/16/2006 1:14:44 PM | P | PASS |
|
|
phil; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ok to cover u/g only
|
ELE06-02020
| Electrical Rough-In | 10/16/2006 | 10/16/2006 | 10/16/2006 10:30:57 AM | P | CANC |
|
|
jeremy Note: underground; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Inspection cancelled from web by: ERIC CENTERS
|
ELE06-03784
| Electrical Rough-In | 10/13/2006 | 10/16/2006 | 10/16/2006 9:57:59 AM | A | CANC |
|
|
eddie; Phone #: ###-#### Internet Inspection Request from: Patricia Smith wrong type inspection, see rip
|
ELE06-03784
| Rough-In Permanent Service | 10/16/2006 | 10/16/2006 | 10/16/2006 9:57:14 AM | A | PASS |
|
|
eddie; Phone #: ###-#### Internet Inspection Request from: Patricia Smith corr made, ric ok, p/s u/g n ok
|
ELE06-03809
| Rough-In Permanent Service | 10/13/2006 | 10/16/2006 | 10/16/2006 9:19:14 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot walls only ok to cover, p/s, exst meter pak ,n, ok
|
ELE06-02426
| Rough-In Permanent Service | 10/13/2006 | 10/16/2006 | 10/16/2006 9:14:04 AM | A | PASS |
|
|
Please call on the way to inspection so we can meet you there to remove panel covers.; Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot ok to cover core,shell walls only p/s u/g n ok , house panel
|
ELE06-03821
| Final | 10/13/2006 | 10/16/2006 | 10/16/2006 8:27:08 AM | A | FAIL |
|
|
curtis; Phone #: ###-#### Internet Inspection Request from: Patricia Smith called, left message, left corr notice, nec 300.4(D) edge of mc cable shall be 1 1/4" from edge of framing members, 330.24 bend radius of mc cable shall be 7x diameter of sheath, 330.30(B) mc cable shall be strapped within 12" of box,110.12(C) there shall be no damaged cable, 210.62 showroom receptacles shall be installed every 12' or fraction thereof for show windows, BCC no violations shall be retained
|