ELE14-00513
| ELE-Aging Inspection | 10/16/2018 | 10/16/2018 | 10/23/2018 3:20:09 PM | | FAIL |
|
|
Building permit has not been issued on this sign
|
ELE18-03738
| Electrical Rough-In | 10/15/2018 | 10/16/2018 | 10/16/2018 3:21:30 PM | P | PASS |
|
|
Aaron Phone #: ###-#### Kitchen remodel rough in ok cover
|
ELE18-03888
| Electrical Rough-In | 10/16/2018 | 10/16/2018 | 10/16/2018 3:01:29 PM | P | PASS |
|
|
underground - tony Phone #: ###-#### From house to tub pad rough in ok cover
|
ELE18-03571
| Final | 10/16/2018 | 10/16/2018 | 10/16/2018 2:42:10 PM | P | PASS |
|
|
Jay Phone #: ###-#### Service only final ok
|
ELE18-03964
| Rough-In Permanent Service | 10/16/2018 | 10/16/2018 | 10/16/2018 2:09:24 PM | P | CANC |
|
|
Call first please Inspect trench for feeder Phone #: ###-#### Inspection requested via web by Eddy Udry Needed underground rough in only.
|
ELE18-03964
| Electrical Rough-In | 10/16/2018 | 10/16/2018 | 10/16/2018 2:09:08 PM | P | PASS |
|
|
Call first please Inspect trench for feeder Phone #: ###-#### Inspection requested via web by Eddy Udry Discussed 250.32(B) equipment ground and grounding electrodes required at seperate house structure. Back window has all operable panes with no wall space to serve kitchen counter space, area to be treated as an island. Full length cabinets planned to most walls in living space shall provide floor or toe kick receptacles to serve wall space. Underground from garage to house rough in ok cover
|
ELE18-03954
| Electrical Rough-In | 10/15/2018 | 10/16/2018 | 10/16/2018 1:29:20 PM | P | PASS |
|
|
For access please call Jamam 1/2 hr prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Terry Scott Entertainment wall, switch for bar, cans in living room rough in ok cover
|
ELE18-03915
| Temporary Service | 10/16/2018 | 10/16/2018 | 10/16/2018 12:38:00 PM | A | PASS |
|
|
call with any questions thank you Phone #: ###-#### Inspection requested via web by kim grundhauser t/s u/g n ok
|
ELE18-02622
| Final | 10/16/2018 | 10/16/2018 | 10/16/2018 12:03:03 PM | A | PASS |
|
|
garage code 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
ELE18-03191
| Rough-In Permanent Service | 10/15/2018 | 10/16/2018 | 10/16/2018 11:22:51 AM | A | PASS |
|
|
Mucho Phone #: ###-#### Rough in ok cover p/s u/g n ok
|
ELE18-03393
| Electrical Rough-In | 10/15/2018 | 10/16/2018 | 10/16/2018 10:43:17 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mark M Office and exam room grid rough in ok cover
|
ELE18-01608
| Electrical Rough-In | 10/15/2018 | 10/16/2018 | 10/16/2018 10:09:13 AM | A | PASS |
|
|
Inspect pool bonding for cover. Phone #: ###-#### Inspection requested via web by Jeremy Cloud Discussed inspections required prior to cover. A concrete encased electrode installed for building 6 and covered. Contact took pictures. This will be only time pictures will be accepted. Discussed 250.32 ex. Seperate buildings do not require a grounding electrode if fed by a single branch circuit or a multi-wire branch circuit that have a equipment grounding conductor. Gator and otter ponds equipotential around each and interior equipment pad rough in ok cover.
|