Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD18-00682 BLD-Framing/Rough-in10/16/201810/16/201810/16/2018 5:28:05 PMPNR
Need Mech rough-in...
No air/foam seal...
BLD17-04425 BLD-Framing/Rough-in10/16/201810/16/201810/16/2018 5:26:57 PMPCANC
Need Mech rough-in...
Air/foam seal...
BLD18-00885 BLD-Other10/15/201810/16/201810/16/2018 5:21:37 PMPPASS
Back porch soffit and drywall only.
BLD18-01272 BLD-Footing10/16/201810/16/201810/16/2018 5:21:19 PMPPASS
late afternoon - Scott Phone #: ###-####
BLD18-01211 BLD-Framing/Rough-in10/16/201810/16/201810/16/2018 5:19:51 PMPFAIL
Anchor bolts to be no more than 12" from ends of sill plate...
Hold downs and straps to be as per plans and installed be Man. Rec...
Per plan note #11, A34 framing anchors required for second story drag truss at interior shear wall...

OK to insulate
BLD18-01784 BLD-Final10/16/201810/16/201810/16/2018 4:08:43 PMPPASS
John Phone #: ###-####
BLD18-01784 DOC - Permit Finaled10/16/201810/16/201810/16/2018 4:08:35 PMPPASS
BLD18-01383 BLD-Energy code compliance10/16/201810/16/201810/16/2018 3:33:41 PMPPASS
Interior remodel, OK to cover...
BLD18-02157 BLD-Energy code compliance10/16/201810/16/201810/16/2018 1:49:04 PMPPASS
BLD18-03153 BLD-Footing10/15/201810/16/201810/16/2018 1:48:50 PMPPASS
As late as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell
BLD18-02157 BLD-Framing/Rough-in10/16/201810/16/201810/16/2018 1:48:35 PMPPASS
Corrections SAT...
BLD18-01357 BLD-Framing/Rough-in10/15/201810/16/201810/16/2018 11:57:48 AMADONE
See Documents, dated 10-16-18, for revised Engineering for framing correction...
Corrections SAT...
BLD18-01897 BLD-Energy code compliance10/16/201810/16/201810/16/2018 11:46:14 AMAPASS
Phone #: ###-#### Inspection requested via web by Braxton Hansen
BLD18-01897 BLD-Framing/Rough-in10/16/201810/16/201810/16/2018 11:33:38 AMAPASS
Corrections SAT...
BLD18-01898 BLD-Energy code compliance10/16/201810/16/201810/16/2018 11:33:19 AMAPASS
Phone #: ###-#### Inspection requested via web by Braxton Hansen
BLD18-01898 BLD-Framing/Rough-in10/16/201810/16/201810/16/2018 11:33:04 AMAPASS
Corrections SAT...
BLD18-03189 BLD-Foundation10/15/201810/16/201810/16/2018 10:42:53 AMAPASS
Work in progress