BLD18-00682
| BLD-Framing/Rough-in | 10/16/2018 | 10/16/2018 | 10/16/2018 5:28:05 PM | P | NR |
|
|
Need Mech rough-in... No air/foam seal...
|
BLD17-04425
| BLD-Framing/Rough-in | 10/16/2018 | 10/16/2018 | 10/16/2018 5:26:57 PM | P | CANC |
|
|
Need Mech rough-in... Air/foam seal...
|
BLD18-00885
| BLD-Other | 10/15/2018 | 10/16/2018 | 10/16/2018 5:21:37 PM | P | PASS |
|
|
Back porch soffit and drywall only.
|
BLD18-01272
| BLD-Footing | 10/16/2018 | 10/16/2018 | 10/16/2018 5:21:19 PM | P | PASS |
|
|
late afternoon - Scott Phone #: ###-####
|
BLD18-01211
| BLD-Framing/Rough-in | 10/16/2018 | 10/16/2018 | 10/16/2018 5:19:51 PM | P | FAIL |
|
|
Anchor bolts to be no more than 12" from ends of sill plate... Hold downs and straps to be as per plans and installed be Man. Rec... Per plan note #11, A34 framing anchors required for second story drag truss at interior shear wall...
OK to insulate
|
BLD18-01784
| BLD-Final | 10/16/2018 | 10/16/2018 | 10/16/2018 4:08:43 PM | P | PASS |
|
|
John Phone #: ###-####
|
BLD18-01784
| DOC - Permit Finaled | 10/16/2018 | 10/16/2018 | 10/16/2018 4:08:35 PM | P | PASS |
|
|
|
BLD18-01383
| BLD-Energy code compliance | 10/16/2018 | 10/16/2018 | 10/16/2018 3:33:41 PM | P | PASS |
|
|
Interior remodel, OK to cover...
|
BLD18-02157
| BLD-Energy code compliance | 10/16/2018 | 10/16/2018 | 10/16/2018 1:49:04 PM | P | PASS |
|
|
|
BLD18-03153
| BLD-Footing | 10/15/2018 | 10/16/2018 | 10/16/2018 1:48:50 PM | P | PASS |
|
|
As late as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell
|
BLD18-02157
| BLD-Framing/Rough-in | 10/16/2018 | 10/16/2018 | 10/16/2018 1:48:35 PM | P | PASS |
|
|
Corrections SAT...
|
BLD18-01357
| BLD-Framing/Rough-in | 10/15/2018 | 10/16/2018 | 10/16/2018 11:57:48 AM | A | DONE |
|
|
See Documents, dated 10-16-18, for revised Engineering for framing correction... Corrections SAT...
|
BLD18-01897
| BLD-Energy code compliance | 10/16/2018 | 10/16/2018 | 10/16/2018 11:46:14 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Braxton Hansen
|
BLD18-01897
| BLD-Framing/Rough-in | 10/16/2018 | 10/16/2018 | 10/16/2018 11:33:38 AM | A | PASS |
|
|
Corrections SAT...
|
BLD18-01898
| BLD-Energy code compliance | 10/16/2018 | 10/16/2018 | 10/16/2018 11:33:19 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Braxton Hansen
|
BLD18-01898
| BLD-Framing/Rough-in | 10/16/2018 | 10/16/2018 | 10/16/2018 11:33:04 AM | A | PASS |
|
|
Corrections SAT...
|
BLD18-03189
| BLD-Foundation | 10/15/2018 | 10/16/2018 | 10/16/2018 10:42:53 AM | A | PASS |
|
|
Work in progress
|