Inspections for the day of: Wednesday, October 16, 2019.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-03722 Electrical Rough-In10/16/201910/16/201910/16/2019 3:59:02 PMPPASS
Please call in advance if possible; 2nd floor. Phone #: ###-#### Inspection requested via web by Steve McCloy
Bathroom, storage, coat rm, switch wall, walls in rooms noted rough in ok cover
ELE19-00602 Electrical Rough-In10/16/201910/16/201910/16/2019 3:30:58 PMPPASS
Cover for SE stairwell in garage. Danny is the contact. Phone #: ###-#### Inspection requested via web by Buster Bowen
Level 4 S.E. stairwell rough in ok cover
ELE19-03543 Electrical Rough-In10/15/201910/16/201910/16/2019 2:13:41 PMPFAIL
Ceiling rough-in inspection
Phone #: ###-#### Inspection requested via web by Kevin Perez
BCC 4-05-32- Code viiolations not to be retained.
* A run of 1/2" EMT leaves this panel and crow flies to front of unit is seperated at couplings and lacks secure and support for the run.
300.18- EMT shall be installed in complete runs.
358.30- In no case shall the supports and secure of EMT exceed 10'.
358.42- Couplings and connectors shall be made tight.
ELE19-01201 Permanent Service10/16/201910/16/201910/16/2019 1:37:32 PMPPASS
Please contact when done Phone #: ###-#### Inspection requested via web by Thomas wilson p/s u/g n ok
ELE19-01201 Electrical Rough-In10/16/201910/16/201910/16/2019 1:14:35 PMPPASS
Please contact when done Phone #: ###-#### Inspection requested via web by Thomas wilson
Underground rough in ok cover Chassis bond ok
ELE19-02904 Final10/16/201910/16/201910/16/2019 1:11:27 PMPPASS
Phone #: ###-#### Inspection requested via web by Jeremy Cloud Final ok
ELE19-03788 Final10/15/201910/16/201910/16/2019 11:18:11 AMACANC
Final for Temp Power
Contact Pierre Elskamp
Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek
Needed temp service inspection. Permit will final when temp service passes.
ELE19-03788 Temporary Service10/16/201910/16/201910/16/2019 10:38:30 AMPPASS
Final for Temp Power
Contact Pierre Elskamp
Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek
t/s u/g n ok
ELE18-04054 Final10/15/201910/16/201910/16/2019 10:09:20 AMAPASS
CONTACT: MIKE MULVAHILL Phone #: ###-#### Inspection requested via web by Deb Gooden Final ok
ELE19-03325 Electrical Rough-In10/15/201910/16/201910/16/2019 10:08:46 AMAPASS
Contact: Mike Mulvahill. ceiling inspection please Phone #: ###-#### Inspection requested via web by Deb Gooden
Grid rough in ok cover.
ELE19-00030 Electrical Rough-In10/15/201910/16/201910/16/2019 9:56:31 AMAPASS
Underground, pole bases Phone #: ###-#### Inspection requested via web by Bryan Atkins West lot center planter underground and 2 pole bases rough in ok cover
ELE19-03928 Rough-In Permanent Service10/14/201910/16/201910/16/2019 9:25:28 AMAFAIL
Phone #: ###-#### Inspection requested via web by Greg Traudt
300.4- Where NM cable has been run thru bored holes that do not maintain 1 1/4" from framing surface they shall be protected from damage by nail plates. Front room corner all sides, under stair above door, upper stair wall, Master bath 12-2.
*Missed wiring can in kitchen near nook.
*Attic boxes trimmed at rough in.
ELE19-02169 Final10/15/201910/16/201910/16/2019 7:08:19 AMPCANC
CONTACT: CINDY WOLFE Phone #: ###-#### >> Inspection requested via web by Deb Gooden Inspection cancelled from web by: Deb Gooden