Inspections for the day of: Monday, October 17, 2005.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-03742 Electrical Rough-In10/17/200510/17/200510/17/2005 4:40:41 PMPDONE
For Approval of Cover; Phone #: ###-#### x114 Internet Inspection Request from: Jim Woodhead done Friday by 336.
ELE05-03347 Final10/17/200510/17/200510/17/2005 3:36:27 PMPPASS
please call 30 min b4 so can let you in//TOLLY; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok to final
ELE05-03648 Rough-In Permanent Service10/14/200510/17/200510/17/2005 2:37:50 PMPPASS
Scheduled by a contractor via Hello! on 10/14/2005 at 12:22:01 PM. Contact: ###-####. ric ok, p/s u/g n ok
ELE05-03635 Permanent Service10/14/200510/17/200510/17/2005 2:19:17 PMPPASS
shane; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ric kitchen only ok, p/s u/g n ok
ELE05-03748 Final10/17/200510/17/200510/17/2005 1:37:00 PMPFAIL
chuck; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok to cover u/g, 408.7 unused openings shall be closed in service.
ELE05-03732 Conference10/14/200510/17/200510/17/2005 10:22:26 AMACANC
please call 30 min prior to meet you///bob; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa see ri
ELE05-03177 Final10/14/200510/17/200510/17/2005 9:15:51 AMAPASS
Charlie; Phone #: ###-#### Internet Inspection Request from: Melyne Davis ok to final
ELE05-03104 Final10/14/200510/17/200510/17/2005 9:11:16 AMAFAIL
READY FOR FINAL INSPECTION FOR THE UPSTAIRS FOR OCCUPANCY. YOU CAN CONTACT THE CONTRACTOR ON HIS CELL PHONE AT ###-####. THANK YOU.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH called contr, left correction notice, 404.9 switches shall have faceplates, 406.4 recpt shall be securely fastened,406.5 recpts shall have faceplates, 406.8(E) floor recpts shall have weatherproof covers, 314.25 boxes shall have covers, 110.12(C) there shall be no broken parts, 110.3 recpts shall be installed correctly,i.e. no hot and gnd reversed, no hots on neutrals, front recpts shalll operate, 210.8(B) gfci recpts shall be provided by sinks
ELE05-03178 Final10/14/200510/17/200510/17/2005 8:05:02 AMAPASS
Charlie; Phone #: ###-#### Internet Inspection Request from: Melyne Davis ok to final
ELE05-03732 Electrical Rough-In10/17/200510/17/200510/17/2005 12:00:00 AMAFAIL
please call 30 min prior to meet you///bob; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa called owner, did conference and r/i since he did over weekend anyway. left corr notice, 312.5 conductors entering enclosure shall have abrasion protection,200.6(B) id shall be provided for grounded conductor, 250.110 metal boxes shall be grounded, 334.30 nm cable shall be stapled within 12 " of box, BCC all make-up shall be done, u/g shall be inspected before cover.