Inspections for the day of: Friday, October 17, 2008.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-02819 Final10/17/200810/17/200810/17/2008 3:43:51 PMPPASS
final on service upgrade, any questions call George @###-#### Phone #: ###-#### Internet Inspection Request from: Andy Rose ok to final, no esc this project
ESC08-00583 General Inspection10/17/200810/17/200810/17/2008 3:30:49 PMPPASS
looked ok
ESC08-00733 General Inspection10/17/200810/17/200810/17/2008 3:29:59 PMAPASS
looked ok
ELE07-04059 Final10/16/200810/17/200810/17/2008 3:29:10 PMPPASS
Scheduled via mobile device. Phone #: 7739684334 ok to final,no esc this project
ELE07-00741 ELE-Aging Inspection10/17/200810/17/200810/17/2008 3:24:01 PM DONE
ok, see final, no esc this project
ELE07-00741 Final10/17/200810/17/200810/17/2008 3:23:29 PMPPASS
ok to final, no esc this project
ELE07-00863 ELE-Aging Inspection10/17/200810/17/200810/17/2008 3:22:03 PM DONE
looked at sign, see final, no esc this project
ELE07-00863 Final10/17/200810/17/200810/17/2008 3:20:32 PMPPASS
looked at sign, ok to final, no esc this project
ELE07-00490 Final10/17/200810/17/200810/17/2008 3:18:15 PMPPASS
ok to final, no esc this project
ELE08-02833 Electrical Rough-In10/17/200810/17/200810/17/2008 2:30:07 PMPPASS
john Phone #: ###-#### met contractor, ric ok, no esc this project
ELE08-02800 Rough-In Permanent Service10/17/200810/17/200810/17/2008 2:00:26 PMPNH
House is unoccupied front door is unlocked Phone #: ###-#### Internet Inspection Request from: Steve Craig called, nh, fee due
ELE08-02700 Electrical Rough-In10/16/200810/17/200810/17/2008 1:06:25 PMPPASS
Scheduled via mobile device. Call for access Phone #: 9361430 ok to cover upper bath and bedroom and 2 front rooms, will call later for floor heat, no esc this project
ELE08-02829 Electrical Rough-In10/16/200810/17/200810/17/2008 11:01:04 AMAPASS
Ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten caled contractor, ric ok
ELE08-02827 Electrical Rough-In10/16/200810/17/200810/17/2008 9:40:40 AMAFAIL
TED. CEILING COVER. CALL PRIOR TO HEADING TO SITE Phone #: ###-#### Internet Inspection Request from: Sean DeLacy met contractor, left correction notice,NEC 710.25 abandoned low voltage wiring shall be removed, 314.23 boxes shall be supported, 314.25 covers shall be on boxes, 358.30 emt shall be strapped, 300.11 shall not use grid for support, 110.26 shall provide working space per code sectiom, BCC no violations shall be retained, NOTE: new work is being done per NEC, no esc this project
ELE08-02770 Electrical Rough-In10/16/200810/17/200810/17/2008 9:39:54 AMAPASS
I have to meet you to let you in, so call me and tell me when you can be there. I cannot be there until 9am, but will meet you any time after that. Phone #: ###-#### Internet Inspection Request from: Andy Derrick ric ok, no esc this project
ELE08-02770 Final10/17/200810/17/200810/17/2008 9:39:36 AMAPASS
I have to meet you to let you in, so call me and tell me when you can be there. I cannot be there until 9am, but will meet you any time after that. Phone #: ###-#### Internet Inspection Request from: Andy Derrick ok to final,no esc this project
ELE08-02827 Electrical Rough-In10/16/200810/17/200810/16/2008 2:18:07 PMPCANC
TED CEILING COVER Phone #: ###-#### Internet Inspection Request from: Sean DeLacy Inspection cancelled from web by: Sean DeLacy