ELE10-00275
| ELE-Aging Inspection | 10/17/2014 | 10/17/2014 | 10/17/2014 3:23:17 PM | | DONE |
|
|
Waiting on owner
|
ELE10-00196
| ELE-Aging Inspection | 10/17/2014 | 10/17/2014 | 10/17/2014 3:13:42 PM | | DONE |
|
|
Still under construction
|
ELE14-02871
| Permanent Service | 10/15/2014 | 10/17/2014 | 10/17/2014 3:06:36 PM | P | PASS |
|
|
Existing house service change and oven wiring. Inspection for reconnect. Phone #: ###-#### Inspection requested via web by Rick Beckman p/s o/h rec ok
|
ELE14-02902
| Electrical Rough-In | 10/17/2014 | 10/17/2014 | 10/17/2014 2:45:24 PM | P | FAIL |
|
|
Just having circuit added inspected, please call Jake when you are on your way. Thank you. Phone #: ###-#### Inspection requested via web by Clay Morgan 300.4(A)(1)&(2)- Where NM cable is ran through notched wood or bored hole that does not maintain 1 1/4" from framing surface it shall be protected from physical damage. NM cable shall also be secured 1 1/4" back from framing surface. 310.16 table as per 334.80- #8 NM cable which feeds hot tub rated at 40 amp max, 50 amp breaker installed. 334.30- NM calbe shall be secured with in 12 " of boxes. Recommend service calculation to ensure hot tub does not over load 100 amp service. Please call with results. ###-####
|
ELE14-02624
| Electrical Rough-In | 10/15/2014 | 10/17/2014 | 10/17/2014 1:58:56 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brandon Blackham Contractor stated NM calbe ran through floor will be behind 2 hour fire rated ceiling on lower level. Rough in ok cover
|
ELE14-02879
| Electrical Rough-In | 10/17/2014 | 10/17/2014 | 10/17/2014 1:27:29 PM | P | PASS |
|
|
For access please call Terry 1/2 hr prior to inspection ###-####. Inspection requested via web by Terry Scott Laundry room remodel rough in ok cover
|
ELE14-02576
| Final | 10/17/2014 | 10/17/2014 | 10/17/2014 12:56:38 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Neal Rumsey Final ok
|
ELE14-02897
| Temporary Service | 10/17/2014 | 10/17/2014 | 10/17/2014 11:04:11 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov t/s u/g n ok
|
ELE14-02863
| Rough-In Permanent Service | 10/16/2014 | 10/17/2014 | 10/17/2014 10:30:19 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov Rough in ok cover p/s u/g n ok
|
ELE14-02891
| Temporary Service | 10/16/2014 | 10/17/2014 | 10/17/2014 9:45:09 AM | A | PASS |
|
|
Inspection requested via web by Rowdy Monroe t/s u/g n ok
|
ELE13-03105
| Electrical Rough-In | 10/16/2014 | 10/17/2014 | 10/17/2014 9:22:36 AM | A | PASS |
|
|
Wall 14 Phone #: ###-#### Inspection requested via web by matt miller Wall 14 rough in ok cover
|
ELE14-02885
| Final | 10/16/2014 | 10/17/2014 | 10/17/2014 8:45:31 AM | A | PASS |
|
|
Building is locked please call prior to inspection Phone #: ###-#### Inspection requested via web by kendall bender Final ok
|
ELE14-02885
| Electrical Rough-In | 10/16/2014 | 10/17/2014 | 10/17/2014 8:44:48 AM | A | PASS |
|
|
Building is locked please call prior to inspection Phone #: ###-#### Inspection requested via web by kendall bender Rough in ok cover
|
ELE14-02624
| Electrical Rough-In | 10/15/2014 | 10/17/2014 | 10/15/2014 7:28:14 PM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Brandon Blackham Inspection cancelled from web by: Brandon Blackham
|