Inspections for the day of: Friday, October 17, 2014.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE10-00275 ELE-Aging Inspection10/17/201410/17/201410/17/2014 3:23:17 PM DONE
Waiting on owner
ELE10-00196 ELE-Aging Inspection10/17/201410/17/201410/17/2014 3:13:42 PM DONE
Still under construction
ELE14-02871 Permanent Service10/15/201410/17/201410/17/2014 3:06:36 PMPPASS
Existing house service change and oven wiring. Inspection for reconnect. Phone #: ###-#### Inspection requested via web by Rick Beckman p/s o/h rec ok
ELE14-02902 Electrical Rough-In10/17/201410/17/201410/17/2014 2:45:24 PMPFAIL
Just having circuit added inspected, please call Jake when you are on your way. Thank you. Phone #: ###-#### Inspection requested via web by Clay Morgan
300.4(A)(1)&(2)- Where NM cable is ran through notched wood or bored hole that does not maintain 1 1/4" from framing surface it shall be protected from physical damage. NM cable shall also be secured 1 1/4" back from framing surface.
310.16 table as per 334.80- #8 NM cable which feeds hot tub rated at 40 amp max, 50 amp breaker installed.
334.30- NM calbe shall be secured with in 12 " of boxes.
Recommend service calculation to ensure hot tub does not over load 100 amp service. Please call with results. ###-####
ELE14-02624 Electrical Rough-In10/15/201410/17/201410/17/2014 1:58:56 PMPPASS
Phone #: ###-#### Inspection requested via web by Brandon Blackham Contractor stated NM calbe ran through floor will be behind 2 hour fire rated ceiling on lower level. Rough in ok cover
ELE14-02879 Electrical Rough-In10/17/201410/17/201410/17/2014 1:27:29 PMPPASS
For access please call Terry 1/2 hr prior to inspection ###-####. Inspection requested via web by Terry Scott Laundry room remodel rough in ok cover
ELE14-02576 Final10/17/201410/17/201410/17/2014 12:56:38 PMPPASS
Phone #: ###-#### Inspection requested via web by Neal Rumsey Final ok
ELE14-02897 Temporary Service10/17/201410/17/201410/17/2014 11:04:11 AMAPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov t/s u/g n ok
ELE14-02863 Rough-In Permanent Service10/16/201410/17/201410/17/2014 10:30:19 AMAPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov Rough in ok cover p/s u/g n ok
ELE14-02891 Temporary Service10/16/201410/17/201410/17/2014 9:45:09 AMAPASS
Inspection requested via web by Rowdy Monroe t/s u/g n ok
ELE13-03105 Electrical Rough-In10/16/201410/17/201410/17/2014 9:22:36 AMAPASS
Wall 14 Phone #: ###-#### Inspection requested via web by matt miller Wall 14 rough in ok cover
ELE14-02885 Final10/16/201410/17/201410/17/2014 8:45:31 AMAPASS
Building is locked please call prior to inspection Phone #: ###-#### Inspection requested via web by kendall bender Final ok
ELE14-02885 Electrical Rough-In10/16/201410/17/201410/17/2014 8:44:48 AMAPASS
Building is locked please call prior to inspection Phone #: ###-#### Inspection requested via web by kendall bender Rough in ok cover
ELE14-02624 Electrical Rough-In10/15/201410/17/201410/15/2014 7:28:14 PMACANC
Phone #: ###-#### >> Inspection requested via web by Brandon Blackham Inspection cancelled from web by: Brandon Blackham