Inspections for the day of: Monday, October 17, 2016.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC16-04591 Final10/14/201610/17/201610/17/2016 4:23:42 PMPPASS
Installation of furnace. Requesting a final inspection after pressure test has been completed. Call ahead to Eric @ ###-#### to coordinate inspection time. Phone #: ###-#### Inspection requested via web by Kayla Pinkham
MEC16-04591 Pressure Test10/14/201610/17/201610/17/2016 4:23:22 PMPPASS
Installation of furnace. Pressure Test needed due to installation of high efficiency furnace. Also requested a final inspection after pressure test has been completed. Call ahead to Eric @ ###-#### to coordinate inspection time. Phone #: ###-#### Inspection requested via web by Kayla Pinkham- 5lb flue pass
MEC16-04579 Rough-in10/17/201610/17/201610/17/2016 4:10:21 PMPPASS
Inspection requested via web by Floyd Floyd Peek- corrections made
MEC16-04579 Pressure Test10/17/201610/17/201610/17/2016 4:09:54 PMPPASS
Max will call inspector when all corrections are completed, thank you Inspection requested via web by Floyd Floyd Peek- 20lb gas pass- 5lb flue pass
MEC16-04558 Pressure Test10/13/201610/17/201610/17/2016 3:56:18 PMPPART
Shaun: ###-#### Phone #: ###-#### Inspection requested via web by Frank Marturello
20lb gas pass

5lb flue for 2 furnaces pass

5lb flue for water heater at 1.5 lbs
MEC16-04558 Rough-in10/13/201610/17/201610/17/2016 3:37:18 PMPFAIL
Phone #: ###-#### Inspection requested via web by Frank Marturello- 5lb flue for nwater heater at 1.5lbs- left correction notice on front window
MEC16-03380 Final10/15/201610/17/201610/17/2016 2:31:41 PMPPASS
Please call homeowner, John Fahrer ###-#### when heading his way, he will meet you. Thanks! Inspection requested via web by Floyd Floyd Peek
MEC16-04588 Pressure Test10/17/201610/17/201610/17/2016 1:22:04 PMPPASS
Early PM. Thank you Phone #: ###-#### Inspection requested via web by Xanti Berria- should have been final- 20lb gas pass
MEC16-04588 Final10/17/201610/17/201610/17/2016 1:21:36 PMPPASS
Early PM. Thank you Phone #: ###-#### Inspection requested via web by Xanti Berria - 20lb gas pass
MEC15-04600 Mec-Aging Inspection10/17/201610/17/201610/17/2016 11:26:03 AM CANC
called contractor about permit on hold- she is going to look into this-
MEC15-00640 Mec-Aging Inspection10/17/201610/17/201610/17/2016 11:25:04 AM DONE
expired
MEC15-00640 DOC - Permit Expired10/17/201610/17/201610/17/2016 11:24:28 AMPPASS
MEC16-03793 Final10/11/201610/17/201610/17/2016 11:21:18 AMAPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC16-04594 Rough-in10/14/201610/17/201610/17/2016 11:06:46 AMAFAIL
Call Jason with any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek- dryer vent at roof missing tape on one seam- both flue guages at 0 psi garage and attic- left notice on front window off entry
MEC16-04594 Pressure Test10/14/201610/17/201610/17/2016 11:04:59 AMAPASS
Call Jason with any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek- 20lb gas pass
MEC16-02174 Rough-in10/14/201610/17/201610/17/2016 10:04:03 AMAPASS
Phone #: ###-#### Inspection requested via web by Amanda Farnsworth
area AB bathrooms and showers seal ok- ok to insulate duct

area AC ok to install ceiling grid
MEC16-04579 Rough-in10/17/201610/17/201610/17/2016 9:33:16 AMAFAIL
Inspection requested via web by Floyd Floyd Peek
exhaust flex to bath fans need hooked up

flue guage at 0 psi

1" clearance to insulation shield to b vent and secured so cant move

gas line needs protection where penetrates foundation- retest

register boots need sealed

outside air cant be taken from roof
MEC16-04579 Pressure Test10/17/201610/17/201610/17/2016 9:27:37 AMAFAIL
Thanks, call Max at ###-#### if you need anything Inspection requested via web by Floyd Floyd Peek- gas line thru foundation needs protection- retest after fixed
MEC16-04381 Final10/14/201610/17/201610/17/2016 8:53:46 AMAPASS
Hood is running and ready to be signed off on. I will have a guy there. 8:30 a.m. should be good to go. Phone #: ###-#### Inspection requested via web by Drew Tverdy