ELE18-03560
| Electrical Rough-In | 10/11/2018 | 10/17/2018 | 10/17/2018 2:49:05 PM | P | PASS |
|
|
Please call Mitch, the foreman, when you are on your way ###-#### Phone #: ###-#### Inspection requested via web by Ashley White... UL listed equipment...30A breaker installed in panel...will need access for final
|
ELE14-00813
| Final | 10/17/2018 | 10/17/2018 | 10/17/2018 2:42:00 PM | P | PASS |
|
|
no corrections at time of perm service inspection
|
ELE14-00855
| Final | 10/17/2018 | 10/17/2018 | 10/17/2018 2:39:10 PM | P | PASS |
|
|
no corrections at time of permanent service inspection
|
ELE14-00913
| ELE-Aging Inspection | 10/17/2018 | 10/17/2018 | 10/17/2018 2:38:01 PM | | PASS |
|
|
final scheduled
|
ELE14-00913
| Final | 10/17/2018 | 10/17/2018 | 10/17/2018 2:37:40 PM | P | PASS |
|
|
no corrections at time of permanent service
|
ELE18-02794
| Final | 10/17/2018 | 10/17/2018 | 10/17/2018 1:49:57 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Lynn Cable...ok to final
|
ELE18-02793
| Final | 10/17/2018 | 10/17/2018 | 10/17/2018 1:49:56 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Lynn Cable...ok to final
|
ELE18-02377
| Electrical Rough-In | 10/16/2018 | 10/17/2018 | 10/17/2018 12:38:15 PM | A | PASS |
|
|
We need a wall rough, Kenny is the site contact.Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker... wall cover ok
|
ELE18-03739
| Final | 10/16/2018 | 10/17/2018 | 10/17/2018 12:08:11 PM | A | PASS |
|
|
Pls contact Bryce (Foreman) @ ###-#### or George (Electrician) @ ###-#### one hr prior or if you have any questions. Thank you. Inspection requested via web by Rob Maes... OCPD, disconnect, and labelling ok
|
ELE18-02651
| Final | 10/16/2018 | 10/17/2018 | 10/17/2018 11:54:39 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Thomas Bond...ok to final
|
ELE18-03781
| Final | 10/12/2018 | 10/17/2018 | 10/17/2018 11:28:32 AM | A | PASS |
|
|
Call Foreman with any questions : Bryce Waterman Phone #: ###-#### Inspection requested via web by Rob Maes... OCPD, disconnect and labelling ok
|
ELE18-02300
| Electrical Rough-In | 10/17/2018 | 10/17/2018 | 10/17/2018 11:04:23 AM | A | PASS |
|
|
Bathroom and storage wall cover and vestibule ceiling cover Phone #: ###-#### Inspection requested via web by Jason Parke...ok to cover areas stated
|
ELE18-00849
| Final | 10/16/2018 | 10/17/2018 | 10/17/2018 10:39:43 AM | A | PART |
|
|
Partial Final Phone #: ###-#### Inspection requested via web by Kerri Hamilton...exterior of building minus electrical rm and half of warehouse up to dividing wall...ok GFI protection need added for outlets in wash rm
|
ELE18-02503
| Final | 10/16/2018 | 10/17/2018 | 10/17/2018 9:37:03 AM | A | FAIL |
|
|
Ready for re-inspect of industrial equipment Phone #: ###-#### Inspection requested via web by Paula Gratiot... 1..correct breaker for compressor needs installed-3 phase 2..supports need added to compressor feeds 3..junction box at laser needs addressed-bonded, blank, and KO seal 3..paint booth breaker needs labeled and verified correct size-paper work on booth 4..relocated panel needs labelling completed 5..new drops at poles need GFI protection 110 and 220 up to 50A 6..Boise City ordinance-no violation shall be retaind...visible code violations need fixed-existing panels need labelling, KOs need installed at multiple locations, GFI protection in existing 110 outlets
|