Inspections for the day of: Thursday, October 18, 2007.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Strole
TitlePLM/MEC-INSPECTOR
Phone #794-7913
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM07-03462 Plumbing Rough-in10/18/200710/18/200710/18/2007 4:51:57 PMPFAIL
Thank you. Phone #: ###-#### Internet Inspection Request from: fritz ramisch-set tubs & valves, vents on deck need to extend 7' above deck/roof, hosebibs need to grade so to drain, missing nailplates.
PLM07-02716 Plumbing Rough-in10/18/200710/18/200710/18/2007 3:57:49 PMPFAIL
holly Note: please call 1/2 hr prior Phone #: ###-####,missing nailplates, need to test dwv.
PLM07-03522 Plumbing Rough-in10/18/200710/18/200710/18/2007 3:42:05 PMPPASS
Jeff Coate Phone #: ###-#### Internet Inspection Request from: Jeff Coate
PLM07-00494 Final10/18/200710/18/200710/18/2007 3:22:36 PMPPASS
PLM07-00873 Final10/18/200710/18/200710/18/2007 3:18:52 PMPPASS
Scheduled by a contractor via Hello! on 10/18/2007 at 8:32:50 AM. Contact: ###-####.the toilets need to be pulled & reset when they tile floors & dishwashers inslalled when units are sold, they will have another plumbing company do this work as per conversation with tom miller of level 3 development.
PLM07-00871 Final10/18/200710/18/200710/18/2007 3:14:29 PMPPASS
Scheduled by a contractor via Hello! on 10/18/2007 at 8:35:01 AM. Contact: ###-####.toilets need to be pulled & reset when they tile, as per conversation with tom miller with level 3 development there will be another plumbing company doing this work.
PLM07-01716 Final10/17/200710/18/200710/18/2007 2:35:10 PMPPART
Sean Hartshaffer is the field contact. We need a final on Med Gas and Plumbing Phone #: ###-#### Internet Inspection Request from: Heidi Mallet-need to label all med gas, need 2" c/o's on island sinks, use directional fittings on ejector discharge, need med gas papers. temp ok.
PLM06-03546 Final10/16/200710/18/200710/18/2007 1:22:45 PMAPASS
Kenny Phone #: ###-####
PLM07-02299 Plumbing Rough-in10/17/200710/18/200710/18/2007 10:20:44 AMAPASS
david Phone #: ###-####
PLM07-03025 Plumbing Rough-in10/17/200710/18/200710/18/2007 9:40:40 AMAPASS
Call Carlos with questions. Phone #: ###-#### Internet Inspection Request from: raul castanon
PLM07-03271 Plumbing Rough-in10/17/200710/18/200710/18/2007 9:16:42 AMAFAIL
CALL ROGER TO SCHEDULE ###-#### ROUGH INSPECTION Phone #: ###-#### Internet Inspection Request from: Allison Briggs-fik backgrade on 2nd flr toilet & kitchen sink drain in crawl & kitchen traparm, fix backgrade on 1st flr tub vent, missing nailplates, retest dwv.