Inspections for the day of: Thursday, October 18, 2012.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE10-01593 ELE-Aging Inspection10/18/201210/18/201210/18/2012 4:06:32 PM DONE
still under construction
ELE12-02329 Final10/18/201210/18/201210/18/2012 3:51:47 PMPNH
Phone #: ###-#### >> Inspection requested via web by Darryn Coburn No access
ELE12-02461 Electrical Rough-In10/18/201210/18/201210/18/2012 3:36:37 PMPPASS
underground inspection Phone #: ###-#### >> Inspection requested via web by Celinda Winters rough-in ok cover underground front 5 pole bases w/connecting raceways
ELE12-02588 Final10/18/201210/18/201210/18/2012 3:03:32 PMPPASS
wired new heat pump, any questions call Jake @ ###-#### Phone #: ###-#### >> Inspection requested via web by Andy Rose final ok
ELE12-02590 Electrical Rough-In10/18/201210/18/201210/18/2012 3:00:16 PMPFAIL
underground cover Phone #: ###-#### >> Inspection requested via web by Dan Rohl NEC 300.5 minimum depth required is 18 in
ELE12-02586 Rough-In Permanent Service10/18/201210/18/201210/18/2012 1:51:47 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Zane Robertson NEC 330.23 guard strips are required within 6ft. of access hole, Mud rings missing.
ELE12-00657 Rough-In Permanent Service10/18/201210/18/201210/18/2012 1:51:01 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Zane Robertson NEC 330.23 Guard strips within 6ft of access hole, mud rings missing, 1 1/4 at washer receptacle
ELE12-01990 Final10/18/201210/18/201210/18/2012 12:59:42 PMPFAIL
Garage key code for access 6622 enter Phone #: ###-#### >> Inspection requested via web by daniel bibikov Tile being removed from kitchen
ELE12-02592 Permanent Service10/18/201210/18/201210/18/2012 12:44:18 PMPFAIL
IDP reconnect. Man door to garage is open and located by front door. Call with problems. Thankss, Phone #: ###-#### >> Inspection requested via web by Eric Schroeder Neutral and grounding conductors shall not be terminated together, All breakers shall be of the same brand of serviced panel, NEC 110.26 working clearance in front of service panel, Strap service raiser within 3ft. of meter.
ELE12-02580 Rough-In Permanent Service10/17/201210/18/201210/18/2012 11:45:00 AMPCANC
Need later in the afternoon if possible. Please call the electrician on site. Randy at ###-####. Need ok for Idaho Power to restore power Phone #: ###-#### >> Inspection requested via web by Randy Fletcher Inspection cancelled from web by: Randy Fletcher
ELE12-02558 Permanent Service10/17/201210/18/201210/18/2012 10:50:38 AMAPASS
Please call Clay when you are on your way, he would like to meet you there. Thank You. Phone #: ###-#### >> Inspection requested via web by Clay Morgan p/s u/g rec ok (single meter)
ELE12-00802 Electrical Rough-In10/17/201210/18/201210/18/2012 9:45:30 AMAPASS
Underground, call Greg Crithfield ###-####
(By trash compactor) Phone #: ###-#### >> Inspection requested via web by Debby Ellis rough-in ok cover underground service lateral conduits
ELE12-02348 Electrical Rough-In10/17/201210/18/201210/18/2012 9:10:32 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Clint Tate rough-in ok cover lobby wall
ELE12-02263 Final10/17/201210/18/201210/18/2012 8:51:47 AMAPASS
Phone #: ###-#### >> Inspection requested via web by ERIC CENTERS final ok
ELE12-02043 Final10/17/201210/18/201210/18/2012 8:32:18 AMAPASS
garage code is 6288 enter Phone #: ###-#### >> Inspection requested via web by Zane Robertson final ok