ELE10-01593
| ELE-Aging Inspection | 10/18/2012 | 10/18/2012 | 10/18/2012 4:06:32 PM | | DONE |
|
|
still under construction
|
ELE12-02329
| Final | 10/18/2012 | 10/18/2012 | 10/18/2012 3:51:47 PM | P | NH |
|
|
Phone #: ###-#### >> Inspection requested via web by Darryn Coburn No access
|
ELE12-02461
| Electrical Rough-In | 10/18/2012 | 10/18/2012 | 10/18/2012 3:36:37 PM | P | PASS |
|
|
underground inspection Phone #: ###-#### >> Inspection requested via web by Celinda Winters rough-in ok cover underground front 5 pole bases w/connecting raceways
|
ELE12-02588
| Final | 10/18/2012 | 10/18/2012 | 10/18/2012 3:03:32 PM | P | PASS |
|
|
wired new heat pump, any questions call Jake @ ###-#### Phone #: ###-#### >> Inspection requested via web by Andy Rose final ok
|
ELE12-02590
| Electrical Rough-In | 10/18/2012 | 10/18/2012 | 10/18/2012 3:00:16 PM | P | FAIL |
|
|
underground cover Phone #: ###-#### >> Inspection requested via web by Dan Rohl NEC 300.5 minimum depth required is 18 in
|
ELE12-02586
| Rough-In Permanent Service | 10/18/2012 | 10/18/2012 | 10/18/2012 1:51:47 PM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Zane Robertson NEC 330.23 guard strips are required within 6ft. of access hole, Mud rings missing.
|
ELE12-00657
| Rough-In Permanent Service | 10/18/2012 | 10/18/2012 | 10/18/2012 1:51:01 PM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Zane Robertson NEC 330.23 Guard strips within 6ft of access hole, mud rings missing, 1 1/4 at washer receptacle
|
ELE12-01990
| Final | 10/18/2012 | 10/18/2012 | 10/18/2012 12:59:42 PM | P | FAIL |
|
|
Garage key code for access 6622 enter Phone #: ###-#### >> Inspection requested via web by daniel bibikov Tile being removed from kitchen
|
ELE12-02592
| Permanent Service | 10/18/2012 | 10/18/2012 | 10/18/2012 12:44:18 PM | P | FAIL |
|
|
IDP reconnect. Man door to garage is open and located by front door. Call with problems. Thankss, Phone #: ###-#### >> Inspection requested via web by Eric Schroeder Neutral and grounding conductors shall not be terminated together, All breakers shall be of the same brand of serviced panel, NEC 110.26 working clearance in front of service panel, Strap service raiser within 3ft. of meter.
|
ELE12-02580
| Rough-In Permanent Service | 10/17/2012 | 10/18/2012 | 10/18/2012 11:45:00 AM | P | CANC |
|
|
Need later in the afternoon if possible. Please call the electrician on site. Randy at ###-####. Need ok for Idaho Power to restore power Phone #: ###-#### >> Inspection requested via web by Randy Fletcher Inspection cancelled from web by: Randy Fletcher
|
ELE12-02558
| Permanent Service | 10/17/2012 | 10/18/2012 | 10/18/2012 10:50:38 AM | A | PASS |
|
|
Please call Clay when you are on your way, he would like to meet you there. Thank You. Phone #: ###-#### >> Inspection requested via web by Clay Morgan p/s u/g rec ok (single meter)
|
ELE12-00802
| Electrical Rough-In | 10/17/2012 | 10/18/2012 | 10/18/2012 9:45:30 AM | A | PASS |
|
|
Underground, call Greg Crithfield ###-#### (By trash compactor) Phone #: ###-#### >> Inspection requested via web by Debby Ellis rough-in ok cover underground service lateral conduits
|
ELE12-02348
| Electrical Rough-In | 10/17/2012 | 10/18/2012 | 10/18/2012 9:10:32 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Clint Tate rough-in ok cover lobby wall
|
ELE12-02263
| Final | 10/17/2012 | 10/18/2012 | 10/18/2012 8:51:47 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by ERIC CENTERS final ok
|
ELE12-02043
| Final | 10/17/2012 | 10/18/2012 | 10/18/2012 8:32:18 AM | A | PASS |
|
|
garage code is 6288 enter Phone #: ###-#### >> Inspection requested via web by Zane Robertson final ok
|