ELE08-01084
| ELE-Aging Inspection | 10/18/2013 | 10/18/2013 | 10/18/2013 3:55:25 PM | | DONE |
|
|
Still under construction
|
GCE13-00165
| GCE-Final | 10/18/2013 | 10/18/2013 | 10/18/2013 3:52:06 PM | P | CANC |
|
|
(Mandatory Inspection) Brayden ###-#### Temp service inspection is final.
|
GCE13-00163
| GCE-Final | 10/18/2013 | 10/18/2013 | 10/18/2013 3:51:07 PM | P | CANC |
|
|
(Mandatory Inspection) Brayden ###-#### Temp service inspection is the final
|
GCE13-00165
| GCE-Temporary Service | 10/18/2013 | 10/18/2013 | 10/18/2013 3:50:18 PM | P | PASS |
|
|
t/s u/g n ok
|
GCE13-00163
| GCE-Temporary Service | 10/18/2013 | 10/18/2013 | 10/18/2013 3:48:10 PM | P | PASS |
|
|
Brayden ###-#### t/s u/g n ok
|
ELE13-02906
| Electrical Rough-In | 10/17/2013 | 10/18/2013 | 10/18/2013 3:32:19 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Don Conley Kitchen remodel rough in ok cover
|
ELE13-02810
| Electrical Rough-In | 10/18/2013 | 10/18/2013 | 10/18/2013 3:03:19 PM | P | PART |
|
|
Interior underground inspection. Contact on the job is Jay Sprik. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery 514.9- All conduits that run to or through hazardous locations shall have seals at both ends. Non metalloc conduits ok 2' and deeper. Where conduit is less than 2' it shall be rigid or IMC. Rough in central area ok cover.
|
ELE13-01051
| Electrical Rough-In | 10/17/2013 | 10/18/2013 | 10/18/2013 2:24:25 PM | P | PASS |
|
|
bruce Phone #: ###-#### Rough in ok cover
|
ELE13-01051
| Permanent Service | 10/18/2013 | 10/18/2013 | 10/18/2013 2:24:10 PM | P | FAIL |
|
|
bruce Phone #: ###-#### 230.28- Over head service mast used to support service drop shall be of adequate strength to with stand stress imposed on it.
|
ELE13-01671
| Final | 10/18/2013 | 10/18/2013 | 10/18/2013 1:45:43 PM | P | FAIL |
|
|
Garage code is 6767, also key is in front outlet. Phone #: ###-#### >> Inspection requested via web by TOM BICANDI 406.5- Receptical face plates shall be installed. Garage 210.8- Receptical located with in 6' of sink shall have GFCI protection. 210.52- 2' wall space in bed shall have receptical outlet installed. 314.16- Boxes shall be of sufficient size to provide space for all conductors. Island.
|
MIS13-00185
| MIS-Aging Inspection | 10/18/2013 | 10/18/2013 | 10/18/2013 1:08:19 PM | P | DONE |
|
|
Called tenant, he will contact contractor doing work to inform of electrical permit and inspections
|
ELE13-02647
| Electrical Rough-In | 10/17/2013 | 10/18/2013 | 10/18/2013 12:51:48 PM | A | PASS |
|
|
Contact: Brian Giacomino, partial final please Phone #: ###-#### >> Inspection requested via web by Deb Gooden Furniture panel upgrades 3rd floor, west side from windows M thru V rough in ok to occupy
|
ELE13-02057
| Electrical Rough-In | 10/17/2013 | 10/18/2013 | 10/18/2013 10:42:30 AM | A | PASS |
|
|
Conduit for Fire Pump. Jim on site Phone #: ###-#### >> Inspection requested via web by Buster Bowen Underground to fire pump service rough in ok cover
|
ELE13-02090
| Final | 10/17/2013 | 10/18/2013 | 10/18/2013 10:04:51 AM | A | FAIL |
|
|
Please call so I can let you in. Thanks Eddy Phone #: ###-#### >> Inspection requested via web by Eddy Udry All recepticals installed ok. Counter extended shall add receptical to comply with 210.52.
|
ELE13-02149
| Final | 10/17/2013 | 10/18/2013 | 10/18/2013 9:52:14 AM | A | FAIL |
|
|
clyde Phone #: ###-#### 110.7- incomplete wiring installation. Receptical outlet not working. 406.5- Receptical faceplates shall completely cover and seat against mounting surface.
|
ELE13-02228
| Final | 10/17/2013 | 10/18/2013 | 10/18/2013 9:36:46 AM | A | PASS |
|
|
It will be open. Thanks Phone #: ###-#### >> Inspection requested via web by Clay Morgan Final ok
|
GCE13-00170
| GCE-Rough-In Permanent Service | 10/17/2013 | 10/18/2013 | 10/18/2013 9:22:25 AM | A | PASS |
|
|
###-#### Daniel Service only rough in ok p/s u/g n ok
|
GCE13-00139
| GCE-Final | 10/17/2013 | 10/18/2013 | 10/18/2013 8:58:19 AM | A | FAIL |
|
|
Terry ###-#### 210.52- 4' wall space in spare bed shall have required receptical outlet. 422.30- A disconnecting means shall be provided for fixed appliances. Built in oven lock-out. *Panel cover shall be completely secured.
|