Inspections for the day of: Tuesday, October 18, 2016.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-00382 ELE-Aging Inspection10/18/201610/18/201610/18/2016 3:29:21 PM CANC
too busy
ELE16-03389 Rough-In Permanent Service10/18/201610/18/201610/18/2016 3:08:26 PMPCANC
underground electrical for conference room ; electrical service panel Phone #: ###-#### Inspection requested via web by Harvey Reyna...

wrong inspection
ELE16-03389 Temporary Service10/18/201610/18/201610/18/2016 3:07:57 PMPPASS
underground electrical for conference room ; electrical service panel Phone #: ###-#### Inspection requested via web by Harvey Reyna...

t/s u/g n ok
ELE16-03389 Electrical Rough-In10/18/201610/18/201610/18/2016 3:05:32 PMPPASS
underground electrical for conference room ; electrical service panel Phone #: ###-#### Inspection requested via web by Harvey Reyna...floor outlet conference room ok to cover
ELE15-03172 Final10/17/201610/18/201610/18/2016 1:13:32 PMPPASS
Phone #: ###-#### Inspection requested via web by Tom Noeker....ok to final
ELE16-01749 Final10/17/201610/18/201610/18/2016 12:55:12 PMPFAIL
Phone #: ###-#### Inspection requested via web by Neal Rumsey.....

service outlet for a/c needs installed within 25'-210.63

over 2' without an outlet-dining room-210.52

both island outlet and pennisula outlet - wire needs protection from physical damage, boxes are not rated for use, and box on island has been modified-110.3(a),110.3(b),110.7

hood circuit needs breaker lockout installed
ESC16-01230 Random Inspection10/18/201610/18/201610/18/2016 10:16:57 AMAPASS
site garabage box being used, onsite grounds clean, and inlet protection being used
ESC16-00994 Site Final10/18/201610/18/201610/18/2016 10:03:16 AMAPASS
ok to final
ELE15-04055 Final10/17/201610/18/201610/18/2016 10:02:16 AMPPASS
Phone #: ###-#### Inspection requested via web by Tom Noeker.....ok to final
ELE16-02731 Final10/17/201610/18/201610/18/2016 9:34:06 AMAPASS
Contact: Justin Hamby Phone #: ###-#### Inspection requested via web by Laurie Hoelscher...."edwardjones" front entry-listing/labelling and disconnect ok...ok to final
ELE16-00908 Final10/17/201610/18/201610/18/2016 9:23:26 AMAPASS
Contact: Justin Hamby Phone #: ###-#### Inspection requested via web by Laurie Hoelscher.....

eastside sign "all american foods" listing and labelling correct with disconnect...eastside and southside "KFC" disconnects on rooftop...ok to final
ESC16-01019 Site Final10/18/201610/18/201610/18/2016 8:38:41 AMAPASS
ok to final
ELE16-03365 Temporary Service10/17/201610/18/201610/18/2016 8:34:22 AMAPASS
Phone #: ###-#### Inspection requested via web by Zane Robertson....

t/s u/g n ok