Inspections for the day of: Tuesday, October 19, 2004.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE04-03218 Rough-In Permanent Service10/18/200410/19/200410/19/2004 12:00:00 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson r/i ok unfinished basement,, called about clearence closet fixture p/s u/g new ok 10/19/2004 8:30:33 AM
ELE04-02963 Electrical Rough-In10/19/200410/19/200410/19/2004 12:00:00 AMAPART
pantry light, iron circuit a/c conduit. thanx jack; Phone #: ###-#### Internet Inspection Request from: joe wheeler ok 10/19/2004 8:43:18 AM
ELE04-03214 Rough-In Permanent Service10/18/200410/19/200410/19/2004 12:00:00 AMAFAIL
craig ###-#### cor. posted called left message needs lights for inside for panel, 250.8 no SMS plugs that bond metal, 110.14,110.3(A) wire ringed and damaged panels and meterbase, 250.32 pick a method 250.32(B)(1),or (B)(2) 10/19/2004 10:02:36 AM
ELE04-03214 Final10/18/200410/19/200410/19/2004 12:00:00 AMANR
craig ###-#### no power 10/19/2004 9:53:52 AM
ELE04-03215 Rough-In Permanent Service10/18/200410/19/200410/19/2004 12:00:00 AMAFAIL
criag ###-#### see comments for PM# ele04-03214 cor. posted 10/19/2004 10:03:35 AM
ELE04-03215 Final10/18/200410/19/200410/19/2004 12:00:00 AMANR
craig ###-#### no power 10/19/2004 9:54:03 AM
ELE04-03213 Conference10/18/200410/19/200410/19/2004 12:00:00 AMPDONE
Scheduled by a contractor via Hello! on 10/18/2004 at 4:35:52 PM. Contact: ###-####. ok needs to uncover u/g covered before inspection 10/19/2004 3:07:27 PM
ELE04-01825 Permanent Service10/19/200410/19/200410/19/2004 12:00:00 AMPPASS
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles p/s u/g new ok 10/19/2004 11:04:39 AM
ELE04-03224 Temporary Service10/19/200410/19/200410/19/2004 12:00:00 AMPFAIL
lars ###-#### cor. posted clean dirt from t/s seal KOs, use manufactures listed breakers only, use green or bare GEC called 10/19/2004 3:06:47 PM
ELE04-03216 Temporary Service10/19/200410/19/200410/19/2004 12:00:00 AMPPASS
justin; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok t/s o/h new ok 10/19/2004 3:37:47 PM
ELE04-02797 Electrical Rough-In10/19/200410/19/200410/19/2004 12:00:00 AMPPART
gerad underground; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok pole lights and phone 10/19/2004 2:01:41 PM
ELE04-03230 Final10/19/200410/19/200410/19/2004 12:00:00 AMPCANC
stephen ###-#### called this is a t/s for 10-20-04 AM and north, not west contractor will reschedule there was some kind of mix up 10/19/2004 1:39:16 PM
ELE04-03234 Final10/19/200410/19/200410/19/2004 12:00:00 AMPCANC
###-#### - john contractor called and canceled 10/19/2004 1:08:40 PM