ELE06-01399
| ELE-Aging Inspection | 10/19/2007 | 10/19/2007 | 10/26/2007 2:47:20 PM | | DONE |
|
|
see final
|
ELE06-01281
| ELE-Aging Inspection | 10/19/2007 | 10/19/2007 | 10/22/2007 10:00:16 AM | | DONE |
|
|
see final
|
ELE07-03580
| Final | 10/19/2007 | 10/19/2007 | 10/19/2007 3:44:47 PM | P | PASS |
|
|
butch Phone #: ###-#### ok to final
|
ELE07-03469
| Electrical Rough-In | 10/19/2007 | 10/19/2007 | 10/19/2007 3:11:09 PM | P | PASS |
|
|
holly Phone #: ###-#### garage only ok to cover, pointed out 3 places needing nail plates
|
ELE07-03553
| Electrical Rough-In | 10/18/2007 | 10/19/2007 | 10/19/2007 2:48:42 PM | P | PASS |
|
|
rough-in for kitchen remodel. Will be ready late afternoon, any questions call Jimmy @ ###-#### Phone #: ###-#### Internet Inspection Request from: Andy Rose called contr to tie grounds together and verify 2' wall for receptacle by back door, ric ok kitchen, closet and bath wall only
|
ELE07-03492
| Electrical Rough-In | 10/19/2007 | 10/19/2007 | 10/19/2007 2:01:09 PM | P | PASS |
|
|
CALL PRIOR TO HEADING TO SITE Phone #: ###-#### Internet Inspection Request from: Sean DeLacy ok to pour slab anop
|
ELE07-03404
| Permanent Service | 10/19/2007 | 10/19/2007 | 10/19/2007 1:06:25 PM | P | PASS |
|
|
Final on new service, plus added wiring for new outlets and lights in garage and patio room. Phone #: ###-#### Internet Inspection Request from: Andy Rose ok to final, met contractor
|
ELE07-02790
| Electrical Rough-In | 10/19/2007 | 10/19/2007 | 10/19/2007 12:28:43 PM | P | FAIL |
|
|
rowdy Note: light conduit underground pool Phone #: ###-#### called, left correction notice, nec 352.26 there shall not be more than 4 quarter bends(360 degrees) total between pull points in rnc
|
ELE07-03576
| Rough-In Permanent Service | 10/18/2007 | 10/19/2007 | 10/19/2007 9:48:32 AM | A | PASS |
|
|
shawn Phone #: ###-#### ric ok shop and patio area, need to do kitchen area later, p/s rec u/g ok
|
ELE07-03492
| Electrical Rough-In | 10/18/2007 | 10/19/2007 | 10/19/2007 9:00:14 AM | A | NH |
|
|
DAVE Phone #: ###-#### Internet Inspection Request from: Sean DeLacy called, left message, left card at trailer, do not know what supposed to inspect, said will have to recall
|
ELE07-03144
| Final | 10/18/2007 | 10/19/2007 | 10/19/2007 8:28:52 AM | A | PASS |
|
|
Brryan; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt ok to final, signed occupancy card
|
ELE06-00711
| Final | 10/19/2007 | 10/19/2007 | 10/19/2007 12:00:00 AM | P | PART |
|
|
to is approved for area 1 basement,1st floor,2nd, 3rd 6th floor,7th floor,penthouse per Bill Thomas
|