Inspections for the day of: Tuesday, October 2, 2007.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-01624 Electrical Rough-In10/2/200710/2/200710/2/2007 3:32:04 PMPPASS
Scheduled by a contractor via Hello! on 10/2/2007 at 7:21:04 AM. Contact: ###-####. walls only parts of 1st and second floors anop ok to cover
ELE07-01269 Final10/2/200710/2/200710/2/2007 2:55:33 PMPPASS
ok to final
ELE07-03130 Conference10/2/200710/2/200710/2/2007 2:54:02 PMPDONE
CASEY Phone #: ###-#### talked about new addition, outlet spacing, afci breakers, when to come for ri inspection
ELE06-02298 Rough-In Permanent Service10/1/200710/2/200710/2/2007 2:29:06 PMPPASS
marv - please call 1/2 hr prior to inspection Phone #: ###-#### ri ok for service areas only, will doe areas of ri for house later, p/s u/g n ok
ELE07-03375 Electrical Rough-In10/2/200710/2/200710/2/2007 1:09:39 PMPPASS
trent Phone #: ###-#### walls only ok to cover
ELE07-03374 Electrical Rough-In10/2/200710/2/200710/2/2007 12:55:35 PMPPASS
trent Phone #: ###-#### walls only ok to cover
ELE07-03371 Rough-In Permanent Service10/1/200710/2/200710/2/2007 10:58:12 AMACANC
please call prior to inspection so I can meet you there and explain whats going on thank you Phone #: ###-#### Internet Inspection Request from: Brad Baker see ri and p/s
ELE07-03371 Permanent Service10/2/200710/2/200710/2/2007 10:53:08 AMAPASS
please call prior to inspection so I can meet you there and explain whats going on thank you Phone #: ###-#### Internet Inspection Request from: Brad Baker talked with contr, p/s o/h n ok
ELE07-03371 Electrical Rough-In10/2/200710/2/200710/2/2007 10:52:11 AMANR
please call prior to inspection so I can meet you there and explain whats going on thank you Phone #: ###-#### Internet Inspection Request from: Brad Baker talked with contractor, will do ri later
ELE07-03355 Final10/2/200710/2/200710/2/2007 10:37:12 AMAPASS
p/s u/g n ok
ELE07-03393 Electrical Rough-In10/1/200710/2/200710/2/2007 10:21:23 AMANR
UFFER inspection. Phone #: ###-#### Internet Inspection Request from: Todd Sellman called contr, no steel yet, will recall
ELE07-02620 Final10/2/200710/2/200710/2/2007 10:10:54 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Celinda Winters called contr, ok to final
ELE07-02737 Final10/2/200710/2/200710/2/2007 9:36:25 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Dan Surerus called contr, ok to final, signed occ card
ELE07-03248 Permanent Service10/1/200710/2/200710/2/2007 8:59:54 AMAFAIL
richard Note: please call 30 min to get in Phone #: ###-#### met contr, told correction required 2 ground rods per nec 250.53 (D)(2), will call later after correction made, rest of service ok
ELE07-03394 Electrical Rough-In10/1/200710/2/200710/2/2007 8:37:18 AMAFAIL
george Phone #: ###-#### called, left corr notice, nec 300.4(A) & (D) edge of bored holes, mc cable and ent shall be 1 1/4" from edge of framing members, BCC raceways shall not be run in valley of framing members
ELE07-03392 Electrical Rough-In10/1/200710/2/200710/2/2007 8:20:15 AMAPASS
Rough in on exterior soffit ###-#### Internet Inspection Request from: Todd Holbrook ok to cover soffits only