Inspections for the day of: Tuesday, October 2, 2007.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Strole
TitlePLM/MEC-INSPECTOR
Phone #794-7913
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM07-03326 Water and/or Sewer10/2/200710/2/200710/3/2007 2:46:32 PMPPEND
chad Phone #: ###-####-hard rock installed sewer & water from street to 116' inside property line, they need to pull permit, they also installed a 2nd water & sewer without any permit or inspection.told circle c to hold off on there water & sewer till we figure out what is going on.
PLM07-03329 Plumbing Rough-in10/2/200710/2/200710/2/2007 4:58:06 PMPFAIL
troy Phone #: ###-####-vents need to be 10' away or 3' above opening window. ok to pull test.
PLM07-03328 Plumbing Rough-in10/2/200710/2/200710/2/2007 4:56:53 PMPPASS
troy Phone #: ###-####
PLM07-03312 Plumbing Rough-in10/1/200710/2/200710/2/2007 3:30:57 PMPPART
JOB # 2756 Phone #: ###-#### Internet Inspection Request from: Kim Alderson-rough-in pass, need to talk to perry about 2nd kitchen per building notes.
PLM07-00494 Final10/2/200710/2/200710/2/2007 2:30:35 PMPPART
Scheduled by a contractor via Hello! on 10/2/2007 at 10:14:22 AM. Contact: ###-####.need tempered water to public lavs of 120 degree water or less, dbca needs tested & certified, temp final ok.
PLM07-00871 Final10/2/200710/2/200710/2/2007 2:18:19 PMPNR
Scheduled by a contractor via Hello! on 10/2/2007 at 10:12:37 AM. Contact: ###-####.
PLM07-03129 Groundwork10/1/200710/2/200710/2/2007 12:52:37 PMAPART
Brian Phone #: ###-####-water & sewer & grease line stub into building & piping upstream & downstream off grease interceptor pass. start 24 hr test on interceptor.
PLM07-03128 Groundwork10/1/200710/2/200710/2/2007 12:48:07 PMAPART
Brian Phone #: ###-####-water & sewer stub into building only.
PLM07-00316 PLM-Aging Inspection10/2/200710/2/200710/2/2007 12:46:23 PM PASS
PLM07-00873 PLM-Aging Inspection10/2/200710/2/200710/2/2007 9:22:49 AM PASS