Inspections for the day of: Tuesday, October 2, 2012.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Strole
TitlePLM/MEC-INSPECTOR
Phone #794-7913
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM12-01850 Other10/2/201210/2/201210/5/2012 9:46:04 AMPPEND
waiting to here back from plumber.
MEC12-03361 Final9/26/201210/2/201210/2/2012 3:06:28 PMPPASS
OWNER, JUANITA TEICH, ###-####. GAS WATER HEATER INSTALL. Phone #: ###-#### >> Inspection requested via web by Chris Field
PLM12-01803 Final10/2/201210/2/201210/2/2012 2:50:37 PMPPASS
JOB # 12019. Phone #: ###-#### >> Inspection requested via web by Ann Marie Reyes
MEC12-03335 Pressure Test10/2/201210/2/201210/2/2012 2:45:55 PMPPASS
please call Bill with any questions Phone #: ###-#### >> Inspection requested via web by Nicholas Paige-60 lb test pass.
MEC12-03422 Pressure Test10/2/201210/2/201210/2/2012 1:50:04 PMPFAIL
Brian ###-#### or Jeff ###-####. Phone #: ###-#### x0000 >> Inspection requested via web by Andrea Creek-gas test fail.
MEC12-03422 Rough-in10/2/201210/2/201210/2/2012 1:49:38 PMPFAIL
Brian ###-#### or Jeff ###-####. Phone #: ###-#### x0000 >> Inspection requested via web by Andrea Creek-1-missing register 1st flr per manual-j. 2-some supply runs 1st flr are undersized per manual-j. 3- need to insulate return in garage joist space. 4-gas test fail.
MEC12-03392 Pressure Test10/2/201210/2/201210/2/2012 1:19:34 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Debbie Marino-20 lb gas test pass.
MEC12-03392 Rough-in10/2/201210/2/201210/2/2012 1:18:40 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Debbie Marino
PLM12-02348 Water and/or Sewer10/2/201210/2/201210/2/2012 1:08:38 PMPPASS
PLM12-02348 DOC - Permit Finaled10/2/201210/2/201210/2/2012 1:08:25 PMPPASS
MEC12-03389 Final10/1/201210/2/201210/2/2012 12:55:40 PMPPASS
between 1:00 & 2:00 pm.
MEC11-04076 Final10/1/201210/2/201210/2/2012 11:38:17 AMAPASS
Dave Phone #: ###-####
MEC12-03397 Final9/28/201210/2/201210/2/2012 10:57:34 AMAFAIL
Baldomero Phone #: ###-####-T&P and pan drain need to be piped to an approved location.
GCM12-00183 GCM-Final10/1/201210/2/201210/2/2012 10:48:45 AMAFAIL
Steven @ ###-####-need heat sheild
PLM12-02367 Final10/1/201210/2/201210/2/2012 9:48:25 AMAPASS
please call bill with any questions Phone #: ###-#### >> Inspection requested via web by Nicholas Paige
MEC12-03399 Rough-in9/28/201210/2/201210/2/2012 9:22:13 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Mike Almanza
ESC12-00799 General Inspection10/2/201210/2/201210/2/2012 9:00:21 AM PASS
ESC11-00817 Aging Inspection10/2/201210/2/201210/2/2012 8:42:51 AM PASS
ESC11-00817 DOC - Permit Finaled10/2/201210/2/201210/2/2012 8:42:37 AMPPASS
PLM12-00623 PLM-Aging Inspection10/2/201210/2/201210/2/2012 8:34:21 AM PART
no calls
PLM12-02348 Water and/or Sewer10/2/201210/2/201210/2/2012 8:27:09 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by keith braun-leak on 1st 45 past c/o.
MEC12-02923 Final9/21/201210/2/201210/2/2012 8:04:13 AMAPASS
8 am ###-####
MEC12-03360 Pressure Test9/26/201210/2/20129/26/2012 10:37:56 AMPCANC
GASPIPER MIGUEL ###-####
INSTALLER CHUCK ###-#### Phone #: ###-#### >> Inspection requested via web by Dustin Rich Inspection cancelled from web by: Dustin Rich