Inspections for the day of: Tuesday, October 2, 2012.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-01821 ELE-Aging Inspection10/2/201210/2/201210/9/2012 3:06:18 PM PASS
see final
ELE11-01840 ELE-Aging Inspection10/2/201210/2/201210/2/2012 2:34:31 PM DONE
Left message with electical contractor, in need of final inspection
ELE12-02142 Final10/2/201210/2/201210/2/2012 2:28:12 PMPPASS
Late afternoon if possible, please. Phone #: ###-#### >> Inspection requested via web by Julie Schroder final ok
ELE12-02122 Final10/2/201210/2/201210/2/2012 2:03:46 PMPPASS
Phone #: ###-#### >> Inspection requested via web by steve cooper final ok
ELE11-00169 Final10/1/201210/2/201210/2/2012 1:39:08 PMAPASS
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson final ok
ELE12-02334 Electrical Rough-In10/2/201210/2/201210/2/2012 12:53:20 PMPPASS
al Phone #: ###-#### rough-in ok cover walkin closet
ELE12-02406 Electrical Rough-In10/2/201210/2/201210/2/2012 12:33:55 PMPPASS
Relocated homeowner installed conduit further than 6'' from the pool Phone #: ###-#### >> Inspection requested via web by Lars Johnson rough-in ok cover
ELE12-02444 Electrical Rough-In10/1/201210/2/201210/2/2012 12:17:26 PMAPASS
bathroom amd closet addition Phone #: ###-#### >> Inspection requested via web by Rick Beckman rough-in ok cover
ELE12-02443 Permanent Service10/1/201210/2/201210/2/2012 9:57:26 AMAPASS
power has been off for a year Phone #: ###-#### >> Inspection requested via web by Jay Symonds p/s u/g rec ok
ELE12-02142 Final10/2/201210/2/201210/2/2012 9:23:19 AMAFAIL
if house is locked, call me for code.
Thanks Bob Phone #: ###-#### >> Inspection requested via web by Julie NEC 314.20 Disposal and microwave receptacles require spark rings. Label main breaker. Lighting fixture require at least 50% CFL
ELE12-02198 Electrical Rough-In10/1/201210/2/201210/2/2012 8:47:35 AMAPASS
wall rough-in Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin rough-in ok cover walls as marked and dated on plans NEC 110.26 Personal door shall open in direction of egress and be equipped with panic bar (service equipment room)
ELE12-02419 Electrical Rough-In10/1/201210/2/201210/2/2012 8:12:50 AMAPASS
mike Phone #: ###-#### rough-in ok cover, NEC 210.52(2) shall have floor receptacle behind bedroom door for final