ELE11-01821
| ELE-Aging Inspection | 10/2/2012 | 10/2/2012 | 10/9/2012 3:06:18 PM | | PASS |
|
|
see final
|
ELE11-01840
| ELE-Aging Inspection | 10/2/2012 | 10/2/2012 | 10/2/2012 2:34:31 PM | | DONE |
|
|
Left message with electical contractor, in need of final inspection
|
ELE12-02142
| Final | 10/2/2012 | 10/2/2012 | 10/2/2012 2:28:12 PM | P | PASS |
|
|
Late afternoon if possible, please. Phone #: ###-#### >> Inspection requested via web by Julie Schroder final ok
|
ELE12-02122
| Final | 10/2/2012 | 10/2/2012 | 10/2/2012 2:03:46 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by steve cooper final ok
|
ELE11-00169
| Final | 10/1/2012 | 10/2/2012 | 10/2/2012 1:39:08 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson final ok
|
ELE12-02334
| Electrical Rough-In | 10/2/2012 | 10/2/2012 | 10/2/2012 12:53:20 PM | P | PASS |
|
|
al Phone #: ###-#### rough-in ok cover walkin closet
|
ELE12-02406
| Electrical Rough-In | 10/2/2012 | 10/2/2012 | 10/2/2012 12:33:55 PM | P | PASS |
|
|
Relocated homeowner installed conduit further than 6'' from the pool Phone #: ###-#### >> Inspection requested via web by Lars Johnson rough-in ok cover
|
ELE12-02444
| Electrical Rough-In | 10/1/2012 | 10/2/2012 | 10/2/2012 12:17:26 PM | A | PASS |
|
|
bathroom amd closet addition Phone #: ###-#### >> Inspection requested via web by Rick Beckman rough-in ok cover
|
ELE12-02443
| Permanent Service | 10/1/2012 | 10/2/2012 | 10/2/2012 9:57:26 AM | A | PASS |
|
|
power has been off for a year Phone #: ###-#### >> Inspection requested via web by Jay Symonds p/s u/g rec ok
|
ELE12-02142
| Final | 10/2/2012 | 10/2/2012 | 10/2/2012 9:23:19 AM | A | FAIL |
|
|
if house is locked, call me for code. Thanks Bob Phone #: ###-#### >> Inspection requested via web by Julie NEC 314.20 Disposal and microwave receptacles require spark rings. Label main breaker. Lighting fixture require at least 50% CFL
|
ELE12-02198
| Electrical Rough-In | 10/1/2012 | 10/2/2012 | 10/2/2012 8:47:35 AM | A | PASS |
|
|
wall rough-in Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin rough-in ok cover walls as marked and dated on plans NEC 110.26 Personal door shall open in direction of egress and be equipped with panic bar (service equipment room)
|
ELE12-02419
| Electrical Rough-In | 10/1/2012 | 10/2/2012 | 10/2/2012 8:12:50 AM | A | PASS |
|
|
mike Phone #: ###-#### rough-in ok cover, NEC 210.52(2) shall have floor receptacle behind bedroom door for final
|