PLM15-03391
| Sprinkler (Final) | 10/2/2015 | 10/2/2015 | 10/2/2015 4:25:23 PM | P | PASS |
|
|
Please contact Luis Ornelas @ ###-#### for any questions. Phone #: ###-#### Inspection requested via web by Accounts Payable
|
PLM15-03391
| Water and/or Sewer | 10/1/2015 | 10/2/2015 | 10/2/2015 4:25:01 PM | P | CANC |
|
|
Please contact Luis Ornelas @ ###-#### for any questions. Phone #: ###-#### Inspection requested via web by Accounts Payable
|
PLM15-03398
| Plumbing Rough-in | 10/2/2015 | 10/2/2015 | 10/2/2015 4:11:47 PM | P | PASS |
|
|
PM Please Thank you Phone #: ###-#### Inspection requested via web by Semsudin Konjuhovac
|
PLM15-03406
| Plumbing Rough-in | 10/2/2015 | 10/2/2015 | 10/2/2015 3:57:01 PM | P | FAIL |
|
|
Ken Phone #: ###-#### >need to vent trap seperately, current point of vent with the wye puts to point of vent below the weir and creates an s trap. >905.5 vent pipe opening shall not be below the weir of the trap except on water closet's. >need test on dwv
|
PLM15-03406
| Final | 10/2/2015 | 10/2/2015 | 10/2/2015 3:56:12 PM | P | CANC |
|
|
Ken Phone #: ###-####
|
PLM15-03407
| Water and/or Sewer | 10/2/2015 | 10/2/2015 | 10/2/2015 3:03:54 PM | P | PART |
|
|
Michael Phone #: ###-#### >water service ok >need DCVA on sprinkler certified
|
PLM15-03407
| Plumbing Rough-in | 10/2/2015 | 10/2/2015 | 10/2/2015 3:03:01 PM | P | CANC |
|
|
Michael Phone #: ###-####
|
PLM15-03009
| Plumbing Rough-in | 10/2/2015 | 10/2/2015 | 10/2/2015 2:41:19 PM | P | PASS |
|
|
would like call ahead; Bill Phone #: ###-#### >check water lines on final to be below insulation in attic
|
PLM15-01583
| Final | 10/2/2015 | 10/2/2015 | 10/2/2015 2:11:11 PM | P | PASS |
|
|
if questions call matt @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann
|
PLM15-03417
| Sprinkler (Final) | 10/2/2015 | 10/2/2015 | 10/2/2015 1:55:16 PM | P | FAIL |
|
|
water needs to be on or air test
|
PLM15-03384
| Plumbing Rough-in | 10/1/2015 | 10/2/2015 | 10/2/2015 1:32:52 PM | P | FAIL |
|
|
JOB # 18216. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes >fix backgraded trap arm on ks >strap trap for lav >redo 1 1/2 vent with fittings both lower ks
|
PLM15-03347
| Water and/or Sewer | 10/2/2015 | 10/2/2015 | 10/2/2015 12:53:13 PM | P | FAIL |
|
|
Sewer Inspection. Jack Willis is the Foreman. If he can''t be reached please call Dan Bastian ###-#### Phone #: ###-#### Inspection requested via web by Dan Bastian >bldg permit not issued
|
PLM15-03404
| Groundwork | 10/2/2015 | 10/2/2015 | 10/2/2015 11:02:04 AM | A | PASS |
|
|
Please contact home owner Karen to access entire project. Phone #: ###-#### Inspection requested via web by James Solosabal >groundwork for new sink ok
|
PLM15-03404
| Plumbing Rough-in | 10/1/2015 | 10/2/2015 | 10/2/2015 11:01:04 AM | A | CANC |
|
|
Please contact home owner Karen to access entire project. Phone #: ###-#### Inspection requested via web by James Solosabal
|
PLM15-02417
| Water Heater Final | 10/1/2015 | 10/2/2015 | 10/2/2015 10:36:01 AM | A | PASS |
|
|
Please call Marlys before coming over Phone #: ###-#### Inspection requested via web by ron pierce
|
PLM15-03390
| Water and/or Sewer | 10/1/2015 | 10/2/2015 | 10/2/2015 10:16:44 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Vicki Tallent >need approved plans onsite for commercial inspections.
|
PLM15-03045
| DOC - Permit Finaled | 10/2/2015 | 10/2/2015 | 10/2/2015 9:58:05 AM | P | PASS |
|
|
|
PLM15-03045
| Water and/or Sewer | 10/1/2015 | 10/2/2015 | 10/2/2015 9:57:53 AM | A | PASS |
|
|
insp. on 9/9/15, there was a permit mix up on Apex's side that is now resolved.
|
PLM15-03370
| Water and/or Sewer | 9/30/2015 | 10/2/2015 | 10/2/2015 9:49:52 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Ryan Cheney
|
PLM15-03387
| Plumbing Rough-in | 10/2/2015 | 10/2/2015 | 10/2/2015 9:19:23 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Bennett
|
PLM15-02310
| Plumbing Rough-in | 10/1/2015 | 10/2/2015 | 10/2/2015 9:18:53 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Brandon Rohricht >fix leak on DWv and RD overflow >add c/o to urinal >add c/o's to RD's
|
PLM15-01710
| PLM-Aging Inspection | 10/2/2015 | 10/2/2015 | 10/2/2015 7:50:49 AM | | PART |
|
|
WIP
|
PLM15-03391
| Water and/or Sewer | 10/1/2015 | 10/2/2015 | 10/1/2015 11:35:47 AM | A | CANC |
|
|
Please contact Luis Ornelas @ ###-#### for any questions. Phone #: ###-#### >> Inspection requested via web by Accounts Payable Inspection cancelled from web by: Accounts Payable
|
PLM15-03388
| Water Heater Final | 10/1/2015 | 10/2/2015 | 10/1/2015 8:52:40 AM | A | CANC |
|
|
Please call Marlys before coming over. Phone #: ###-#### >> Inspection requested via web by ron pierce Inspection cancelled from web by: ron pierce
|