ELE18-03048
| Final | 10/2/2018 | 10/2/2018 | 10/2/2018 2:30:32 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Robert Carter Final ok
|
ELE18-03607
| Electrical Rough-In | 10/2/2018 | 10/2/2018 | 10/2/2018 1:59:40 PM | P | PASS |
|
|
North canopy Phone #: ###-#### Inspection requested via web by Ron Zimmerman Rough in ok cover
|
ELE18-03757
| Conference | 10/2/2018 | 10/2/2018 | 10/2/2018 1:41:12 PM | P | PASS |
|
|
Justin Phone #: ###-#### Discussed 200amp service and overhead clearence of service entrance conductors. Miscommumication with Idaho power on how easy it would be to get around tall shop and refeed house. Roof pitch on shop 3x12 suggested building a stand off on corner of shop and stay below roof to avoid above roof requirements. Has provided a grounding electrode system of ground rods 5'5" apart. Concrete encased electrode is provided on east wall that will be connected when framing complete on that wall. Discussed interior receptacle locations and types and required lights for interior and man doors.
|
ELE18-03338
| Electrical Rough-In | 10/1/2018 | 10/2/2018 | 10/2/2018 11:31:37 AM | A | PASS |
|
|
Jason Curley ###-#### Phone #: ###-#### Inspection requested via web by BRS Permitting Listing confirmed on roof equipment. Rough in ok
|
ELE18-03758
| Final | 10/1/2018 | 10/2/2018 | 10/2/2018 10:54:09 AM | A | FAIL |
|
|
Connected whip to A/C unit from disconnect. NOTE: owner installed disconnect and wire. Phone #: ###-#### Inspection requested via web by Kendra Lanham BCC 04-05-21- Electrical permit required to cover from outdoor panel to HVAC disconnect. Owner stated he provided conduit and wire and electrical contractor terminated wiring. Either owner pulls permit for feed to disconnect or contractor takes responcibility for entire branch circuit.
110.14- Grounding terminations in panel, up to 3 under each termination, but shall be of same size conductor. 110.26- HVAC fused disconnect shall have minimum work space provided 30" wide and 36" deep. Now located behind HVAC unit.
|
ELE18-03666
| Permanent Service | 10/1/2018 | 10/2/2018 | 10/2/2018 10:09:39 AM | A | PASS |
|
|
Inspector requested mast to be elevated for clearance over parking area. Need a pass for coordination with Idaho Power Phone #: ###-#### Inspection requested via web by Kendra Lanham p/s o/h rec ok
|
ELE18-03667
| Final | 10/1/2018 | 10/2/2018 | 10/2/2018 9:51:46 AM | A | PASS |
|
|
Please call Micah Hornback at ###-#### so that I can have someone meet you on site for this inspection. Thank you! Phone #: ###-#### Inspection requested via web by Jesse Simpson Final ok
|
ELE18-03388
| Electrical Rough-In | 10/1/2018 | 10/2/2018 | 10/2/2018 9:26:02 AM | A | PASS |
|
|
Wall cover for kitchen and entertainment room. Greg ###-####. Thank you Phone #: ###-#### Inspection requested via web by Steve Blackmer Kitchen, bathrooms, family rm rough in ok cover.
|
ELE18-00849
| Electrical Rough-In | 10/1/2018 | 10/2/2018 | 10/2/2018 8:45:47 AM | A | PART |
|
|
Roger ###-#### Phone #: ###-#### Inspection requested via web by Kerri Hamilton Roger not contact Bob is @ ###-#### 300.4- Cables shall not be installed with in 1 1/2" of corregated roof. S.W offices and corridor. N.W. offices level 2 grid rough in ok cover.
|