Inspections for the day of: Tuesday, October 2, 2018.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-00120 ELE-Aging Inspection10/2/201810/2/201810/10/2018 7:48:54 AM FAIL
still has parcel hold
ELE18-01526 Final9/30/201810/2/201810/2/2018 2:13:22 PMPPASS
code1830 Phone #: ###-#### Inspection requested via web by Neal Rumsey Final ok
ELE18-03773 Electrical Rough-In10/2/201810/2/201810/2/2018 1:17:52 PMPPASS
Underground Phone #: ###-#### Inspection requested via web by Zane Robertson Underground in kitchen area ok to cover
ELE18-03761 Temporary Service10/2/201810/2/201810/2/2018 1:17:17 PMPPASS
Temp power Phone #: ###-#### Inspection requested via web by Zane Robertson t/s u/g n ok
ELE18-03244 Final10/2/201810/2/201810/2/2018 12:38:39 PMPFAIL
Phone #: ###-#### Inspection requested via web by Ashley Rasmussen Connectors and Cupplings Shall be made wrench tight. (All Compression raintight fittings)
ELE18-03244 Electrical Rough-In10/2/201810/2/201810/2/2018 12:38:31 PMPPASS
Phone #: ###-#### Inspection requested via web by Ashley Rasmussen Listing only ok
ELE18-03768 Electrical Rough-In10/2/201810/2/201810/2/2018 12:24:24 PMPPASS
David Joseph ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg 210.70A3. Attics used for storage shall have light controlled by a switch.(needed before final) 2 bedroom extension ok to cover.
ELE18-03745 Rough-In Permanent Service10/2/201810/2/201810/2/2018 11:32:27 AMPPASS
Call with any questions, thank you. Phone #: ###-#### Inspection requested via web by kim grundhauser rough in ok p/s u/g n okl
ELE18-02910 Final10/2/201810/2/201810/2/2018 11:21:38 AMAPASS
Phone #: ###-#### Inspection requested via web by Patrick Paz Final ok
ELE18-02747 Final10/1/201810/2/201810/2/2018 10:48:40 AMAPASS
This is the one I sent you a picture of the installed vanity light. Phone #: ###-#### Inspection requested via web by Craig Korell Final ok
ELE18-03762 Electrical Rough-In10/1/201810/2/201810/2/2018 10:48:18 AMAPASS
New wall rough-in switch and power Phone #: ###-#### Inspection requested via web by David Feller Reception and waiting areas only ok to cover
ELE17-00480 Electrical Rough-In10/1/201810/2/201810/2/2018 10:26:05 AMAFAIL
Rough in Garage and underground Phone #: ###-#### Inspection requested via web by Don Conley Voicemail full. Unable to leave message. underground ok to cover 210.11C4. At least 1 20A circuit shall supply receps in all Attached and detached Garages. Circuit shall have no others.
ELE18-03743 Rough-In Permanent Service10/1/201810/2/201810/2/2018 10:01:44 AMAPASS
Phone #: ###-#### Inspection requested via web by kevin blackmon Rough in ok p/s u/g n ok
ELE18-01107 Final10/1/201810/2/201810/2/2018 9:20:39 AMAPASS
Phone #: ###-#### Inspection requested via web by Eric Schroeder Can lights only Final ok