Inspections for the day of: Tuesday, October 2, 2018.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-04692 Final9/27/201810/2/201810/2/2018 4:00:09 PMPPASS
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace co ok
MEC18-03509 Final9/27/201810/2/201810/2/2018 3:40:53 PMPPASS
Please call Rachel in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace a/c coil co ok
MEC18-04724 Final10/2/201810/2/201810/2/2018 3:18:32 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace co ok
MEC18-04535 Pressure Test10/1/201810/2/201810/2/2018 2:52:57 PMPPASS
high pressure gas test. Phone #: ###-#### Inspection requested via web by Aaron Alandt- 60lb gas pass existing system- tagged meter- need to verify if CO detectors are installed before final
MEC18-04745 Final10/2/201810/2/201810/2/2018 2:29:37 PMPPASS
Wold like PM and call on way thank you. Phone #: ###-#### Inspection requested via web by Xanti Berria- furnace a/c coil co ok
MEC18-04528 Pressure Test10/2/201810/2/201810/2/2018 2:22:32 PMPPART
Pressure Test Witness - If questions call Ryan @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann- 60lb gas pass lab area wall up into ceiling- will test whole system when installed- ok to cover lab walls
MEC18-03629 Final10/1/201810/2/201810/2/2018 2:03:10 PMPPASS
Phone #: ###-#### Inspection requested via web by Randy Hart
MEC18-03630 Final10/1/201810/2/201810/2/2018 2:02:55 PMPPASS
Phone #: ###-#### Inspection requested via web by Randy Hart
MEC18-04700 Rough-in10/1/201810/2/201810/2/2018 1:32:40 PMPPASS
Phone #: ###-#### Inspection requested via web by Oleg Chervak- fireplace and HVAC R/I ok
MEC18-04700 Pressure Test10/1/201810/2/201810/2/2018 1:32:10 PMPPASS
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass
MEC18-04730 Final10/1/201810/2/201810/2/2018 11:25:42 AMAPASS
PLEASE CALL (HOMEOWNER) MICHELLE @ # LISTED WHEN EN ROUTE. CUST PREFERS BETWEEN 10 A.M. - 12 P.M. TIME FRAME--WILL NOT ANSWER DOOR BEFORE 10 A.M.! Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING- furnace co ok
MEC17-04096 Final10/1/201810/2/201810/2/2018 10:52:15 AMANH
Phone #: ###-#### Inspection requested via web by anthony allen- not home no access- please schedule with homeowner- left notice front door
MEC18-03176 Final10/1/201810/2/201810/2/2018 10:51:43 AMANH
Phone #: ###-#### Inspection requested via web by anthony allen- not home no access- please schedule with homeowner- left notice front door
MEC18-03378 Final10/1/201810/2/201810/2/2018 10:42:34 AMAPASS
Phone #: ###-#### Inspection requested via web by Aaron Alandt- final ok
MEC18-00904 Final10/1/201810/2/201810/2/2018 10:31:00 AMAPASS
Owner: Karan Justus ###-#### asking for a morning inspection please.

Field Super: Chad Robertson ###-#### Phone #: ###-#### Inspection requested via web by Lisa Whitney- final ok
MEC18-04701 Rough-in10/1/201810/2/201810/2/2018 10:00:27 AMAPASS
mec and firepl Phone #: ###-#### Inspection requested via web by Oleg Chervak- fireplace R/I ok- hvac R/I ok
MEC18-04701 Pressure Test10/1/201810/2/201810/2/2018 9:59:52 AMAPASS
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass
MEC18-04716 Final10/2/201810/2/201810/2/2018 9:17:03 AMAPASS
please call half hour prio Phone #: ###-#### Inspection requested via web by thomas nguyen- furnace a/c coil co ok
MEC18-04719 Pressure Test10/1/201810/2/201810/2/2018 8:54:53 AMAFAIL
Phone #: ###-#### Inspection requested via web by Jamie Scibior- gauge at 49 psi- need inert tape on gas line where penetrates into building- sediment traps need to be installed between gas shut off and appliance- b vent needs insulation shields around pipe at ceiling with minimum clearnce of 1" and stubs down 2" below insulation
MEC18-02536 Final10/1/201810/2/201810/2/2018 8:39:57 AMAPASS
Phone #: ###-#### Inspection requested via web by Benny Arreola- final ok
MEC18-02593 Final10/1/201810/2/201810/2/2018 8:39:40 AMAPASS
Phone #: ###-#### Inspection requested via web by Benny Arreola- final ok
MEC18-02260 Final10/1/201810/2/201810/2/2018 8:39:25 AMAPASS
Phone #: ###-#### Inspection requested via web by Benny Arreola- final ok