Inspections for the day of: Tuesday, October 20, 1998.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Storey
TitleBLD-COM/RES INSPECTOR
Phone #794-9490
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD98-02506 INSP - Foundation10/20/199810/20/199810/21/1998 12:00:00 AMPPASS
10/20/98 301 - KEN PAGER ###-#### FTG -OK FOOTING
BLD98-02800 INSP - Framing/Rough-in10/19/199810/20/199810/20/1998 12:00:00 AMAFAIL
10/20/98 301 - trans tom.a102
BLD97-00878 INSP - Framing/Rough-in10/19/199810/20/199810/20/1998 12:00:00 AMAPART
10/20/98 301 - CHRIS ###-#### rebar ok fire places ì
BLD98-01606 INSP - Final10/19/199810/20/199810/20/1998 12:00:00 AMAFAIL
10/20/98 301 - trans to tom0 FN INSP
BLD98-02929 INSP - Foundation10/19/199810/20/199810/20/1998 12:00:00 AMAFAIL
10/20/98 301 - robert- ###-####-fd insp spec 4000 psi concrete, contractor to supply recalulation to 2500 psi by or engineer of record. 3500 psi ordered and on site. rebar in place and ok, hold down bolts ok
BLD98-02487 INSP - Foundation10/19/199810/20/199810/20/1998 12:00:00 AMAPASS
10/20/98 301 - kurt ###-#### for fd insp FDN -OK FOUNDATION
BLD98-03201 INSP - Foundation10/20/199810/20/199810/20/1998 12:00:00 AMPPASS
10/20/98 301 - JOHN ###-#### FTG -OK FOOTING ì
BLD98-01843 INSP - Framing/Rough-in10/19/199810/20/199810/20/1998 12:00:00 AMPFAIL
10/20/98 301 - GEORGE ###-#### CORR-CORREC-CALL FOR REINSP WHEN COMPLETED
BLD98-02238 INSP - Framing/Rough-in10/20/199810/20/199810/20/1998 12:00:00 AMPPART
10/20/98 301 - phil ###-#### shear wall carpentry insp sheer ok
BLD98-02412 INSP - Energy code compliance10/19/199810/20/199810/20/1998 12:00:00 AMPPASS
10/20/98 301 - MIKE REINSPECTION/###-#### INSL-OK INSULATION
BLD98-02412 INSP - Framing/Rough-in10/19/199810/20/199810/20/1998 12:00:00 AMPPASS
10/20/98 301 - REINSPECTION / MIKE ###-#### FRAM-OK FRAMING
BLD98-02421 INSP - Framing/Rough-in10/20/199810/20/199810/20/1998 12:00:00 AMPFAIL
10/20/98 301 - JOHN ###-#### CORR-CORREC-CALL FOR REINSP WHEN COMPLETED planreview isue took approved back to city. no framing insp. could be performed.
BLD98-02800 INSP - Energy code compliance10/20/199810/20/199810/20/1998 12:00:00 AMPFAIL
10/20/98 301 - BRANDON- ###-#### INSULATION INSP CORR-CORREC-CALL FOR REINSP WHEN COMPLETED
BLD98-02868 INSP - Foundation10/19/199810/20/199810/20/1998 12:00:00 AMPPART
10/20/98 301 - Scheduled by Hello!. Contact phone is [4422400]. FTG -OK FOOTING special insp on site pending report 3000 psi concrete