ELE05-03522
| Electrical Rough-In | 10/20/2005 | 10/20/2005 | 10/20/2005 4:25:55 PM | P | PART |
|
|
harold Note: store front ceiling ; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles store front ok to cover anop
|
ELE05-03802
| Electrical Rough-In | 10/19/2005 | 10/20/2005 | 10/20/2005 4:25:21 PM | P | PASS |
|
|
access to unit is at Blimpi talk to Shawn ###-#### called contr to support flex out of box in clg, and 1 1/4 in 1 wall. walls only ok to cover, leave clg open
|
ELE05-03829
| Rough-In Permanent Service | 10/20/2005 | 10/20/2005 | 10/20/2005 2:59:47 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Clyde Logan ric ok, p/s u/g n ok
|
ELE05-03303
| Electrical Rough-In | 10/19/2005 | 10/20/2005 | 10/20/2005 2:44:07 PM | P | FAIL |
|
|
lila or mike; Phone #: ###-#### Internet Inspection Request from: Barbara Moore BCC all make-up shall be done (Ground Wires), 210.52(A) recpt shall be added behind bookcase, 250.80 metal boxes shall be grounded, 312.5 conductors entering boxes shall have abrasion protection, 314.17(C) nm cable shall be stapled within 8" of box,300.4(A) bored hole edge shall be 1 1/4" from edge,300.4(D) nm cable shall be 1 1/4" from edge of framing member, met owner and reviewed, left correction notice, said to recall.
|
ELE05-03809
| Rough-In Permanent Service | 10/20/2005 | 10/20/2005 | 10/20/2005 1:42:24 PM | P | PASS |
|
|
ron; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ric ok, p/s u/g n ok
|
ELE04-03054
| Electrical Rough-In | 10/19/2005 | 10/20/2005 | 10/20/2005 10:06:59 AM | A | PASS |
|
|
POOL EQUIPMENT ROOM ROUGH-IN; Phone #: ###-#### Internet Inspection Request from: Barry Kendall ric ok, 315 saw before covered
|
ELE05-02893
| Final | 10/20/2005 | 10/20/2005 | 10/20/2005 10:05:36 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 10/20/2005 at 7:10:01 AM. corrections made, signed occ card, ok to final
|
ELE05-02806
| Electrical Rough-In | 10/20/2005 | 10/20/2005 | 10/20/2005 9:46:46 AM | P | CANC |
|
|
Phone #: ###-#### Internet Inspection Request from: Ryan Christensen Inspection cancelled from web by: Ryan Christensen
|
ELE05-02932
| Final | 10/19/2005 | 10/20/2005 | 10/20/2005 9:43:29 AM | A | PASS |
|
|
alan; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok to final
|
ELE05-03818
| Temporary Service | 10/19/2005 | 10/20/2005 | 10/20/2005 9:18:44 AM | A | PASS |
|
|
daryl ###-#### t/s u/g n ok
|
ELE05-03817
| Temporary Service | 10/19/2005 | 10/20/2005 | 10/20/2005 9:18:08 AM | A | PASS |
|
|
daryl ###-#### t/s u/g n ok
|
ELE05-03104
| Final | 10/19/2005 | 10/20/2005 | 10/20/2005 8:58:45 AM | A | PART |
|
|
WE ARE READY FOR A FINAL INSPECTION SO THAT THE TENANT CAN GET OCCUPANCY FOR THE MAIN FLOOR. ANY QUESTIONS, PLEASE FEEL FREE TO CALL US. THANK YOU.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH called contr, left corr notice, signed t/o card, NEC 110.3 front ceiling fixtures shall be installed and lower level completed. Note: no access beyond front nw office area shall be permitted. Construction and t/o expire 11-04-05.
|
ELE05-02806
| Electrical Rough-In | 10/19/2005 | 10/20/2005 | 10/20/2005 8:25:16 AM | A | NR |
|
|
INSPECTION FOR THE CEILING COVER; Phone #: ###-#### Internet Inspection Request from: Ryan Christensen called contr, nr, will call ltr
|
ELE05-03674
| Electrical Rough-In | 10/19/2005 | 10/20/2005 | 10/20/2005 8:04:47 AM | A | PART |
|
|
Wall inspection is needed.; Phone #: ###-#### Internet Inspection Request from: Dan Hardisty back walls, 1' of entry clg ok to cover
|