Inspections for the day of: Thursday, October 20, 2005.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-03522 Electrical Rough-In10/20/200510/20/200510/20/2005 4:25:55 PMPPART
harold Note: store front ceiling ; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles store front ok to cover anop
ELE05-03802 Electrical Rough-In10/19/200510/20/200510/20/2005 4:25:21 PMPPASS
access to unit is at Blimpi talk to Shawn ###-#### called contr to support flex out of box in clg, and 1 1/4 in 1 wall. walls only ok to cover, leave clg open
ELE05-03829 Rough-In Permanent Service10/20/200510/20/200510/20/2005 2:59:47 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Clyde Logan ric ok, p/s u/g n ok
ELE05-03303 Electrical Rough-In10/19/200510/20/200510/20/2005 2:44:07 PMPFAIL
lila or mike; Phone #: ###-#### Internet Inspection Request from: Barbara Moore BCC all make-up shall be done (Ground Wires), 210.52(A) recpt shall be added behind bookcase, 250.80 metal boxes shall be grounded, 312.5 conductors entering boxes shall have abrasion protection, 314.17(C) nm cable shall be stapled within 8" of box,300.4(A) bored hole edge shall be 1 1/4" from edge,300.4(D) nm cable shall be 1 1/4" from edge of framing member, met owner and reviewed, left correction notice, said to recall.
ELE05-03809 Rough-In Permanent Service10/20/200510/20/200510/20/2005 1:42:24 PMPPASS
ron; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ric ok, p/s u/g n ok
ELE04-03054 Electrical Rough-In10/19/200510/20/200510/20/2005 10:06:59 AMAPASS
POOL EQUIPMENT ROOM ROUGH-IN; Phone #: ###-#### Internet Inspection Request from: Barry Kendall ric ok, 315 saw before covered
ELE05-02893 Final10/20/200510/20/200510/20/2005 10:05:36 AMPPASS
Scheduled by a contractor via Hello! on 10/20/2005 at 7:10:01 AM. corrections made, signed occ card, ok to final
ELE05-02806 Electrical Rough-In10/20/200510/20/200510/20/2005 9:46:46 AMPCANC
Phone #: ###-#### Internet Inspection Request from: Ryan Christensen Inspection cancelled from web by: Ryan Christensen
ELE05-02932 Final10/19/200510/20/200510/20/2005 9:43:29 AMAPASS
alan; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok to final
ELE05-03818 Temporary Service10/19/200510/20/200510/20/2005 9:18:44 AMAPASS
daryl ###-#### t/s u/g n ok
ELE05-03817 Temporary Service10/19/200510/20/200510/20/2005 9:18:08 AMAPASS
daryl ###-#### t/s u/g n ok
ELE05-03104 Final10/19/200510/20/200510/20/2005 8:58:45 AMAPART
WE ARE READY FOR A FINAL INSPECTION SO THAT THE TENANT CAN GET OCCUPANCY FOR THE MAIN FLOOR. ANY QUESTIONS, PLEASE FEEL FREE TO CALL US. THANK YOU.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH called contr, left corr notice, signed t/o card, NEC 110.3 front ceiling fixtures shall be installed and lower level completed. Note: no access beyond front nw office area shall be permitted. Construction and t/o expire 11-04-05.
ELE05-02806 Electrical Rough-In10/19/200510/20/200510/20/2005 8:25:16 AMANR
INSPECTION FOR THE CEILING COVER; Phone #: ###-#### Internet Inspection Request from: Ryan Christensen called contr, nr, will call ltr
ELE05-03674 Electrical Rough-In10/19/200510/20/200510/20/2005 8:04:47 AMAPART
Wall inspection is needed.; Phone #: ###-#### Internet Inspection Request from: Dan Hardisty back walls, 1' of entry clg ok to cover