Inspections for the day of: Friday, October 20, 2017.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-03552 Permanent Service10/20/201710/20/201710/20/2017 2:08:25 PMPPASS
service change mid afternoon so we can have idaho power reconnect Phone #: ###-#### Inspection requested via web by Chris Berthelot p/s o/h rec ok
ELE17-03548 Electrical Rough-In10/20/201710/20/201710/20/2017 1:30:50 PMPPASS
Please call Tom prior to inspection. Phone #: ###-#### Inspection requested via web by Kevin Perez Kitchen, down bed and living and misc cutin lights through out. Rough in ok
ELE17-03472 Electrical Rough-In10/19/201710/20/201710/20/2017 1:13:42 PMPNR
Phone #: ###-#### Inspection requested via web by Daniel Dow needed conference
ELE17-03472 Conference10/20/201710/20/201710/20/2017 1:13:15 PMPDONE
Phone #: ###-#### Inspection requested via web by Daniel Dow Talked about wire support, AFCI protection on added receps in Master bed, 1/4in Sheathing in boxes, Grounding conductors tied through, Need recep added on wall in kitchen by Peninsula
ELE17-03526 Final10/19/201710/20/201710/20/2017 12:42:05 PMPPASS
We will call to meet you out there Phone #: ###-#### Inspection requested via web by Jesse Simpson Final ok
ELE17-03478 Electrical Rough-In10/20/201710/20/201710/20/2017 12:31:36 PMPNR
Please call prior to heading over so I can meet you there.

Thanks Shawn Phone #: ###-#### Inspection requested via web by Shawn Dulin Not ready. Needed conference
ELE17-03478 Conference10/20/201710/20/201710/20/2017 12:31:25 PMPPASS
Please call prior to heading over so I can meet you there.

Thanks Shawn Phone #: ###-#### Inspection requested via web by Shawn Dulin Talked about Dedicated 20A circuits for water heater and Bath Vanity recep. Also need lght and recep in Attic next to water heater
ELE17-03430 Final10/18/201710/20/201710/20/2017 11:05:08 AMAPASS
CALL AHEAD BEFORE COMING. Please call James at ###-#### ahead of time so he can meet you and give property access Phone #: ###-#### Inspection requested via web by jamie berg Final ok
ELE17-03430 Electrical Rough-In10/20/201710/20/201710/20/2017 11:04:40 AMPPASS
CALL AHEAD BEFORE COMING. Please call James at ###-#### ahead of time so he can meet you and give property access Phone #: ###-#### Inspection requested via web by jamie berg Rough in ok
ELE17-03456 Rough-In Permanent Service10/19/201710/20/201710/20/2017 10:02:27 AMAPASS
Phone #: ###-#### Inspection requested via web by kevin blackmon Rough in ok to cover p/s u/g n ok
ELE17-02954 Electrical Rough-In10/19/201710/20/201710/20/2017 9:34:15 AMAPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Area marked on print. Ceiling only ok to cover
ELE17-03535 Rough-In Permanent Service10/19/201710/20/201710/20/2017 9:33:26 AMAPASS
please call when done Phone #: ###-#### Inspection requested via web by Thomas wilson Underground ok to cover. p/s u/g rec ok
ELE17-03546 Permanent Service10/19/201710/20/201710/20/2017 9:00:05 AMPCANC
Phone #: ###-#### >> Inspection requested via web by cris flores Inspection cancelled from web by: cris flores