MEC17-04668
| Conference | 10/20/2017 | 10/20/2017 | 10/20/2017 4:14:41 PM | P | DONE |
|
|
Call before you come so we can meet you there. ###-#### Phone #: ###-#### Inspection requested via web by Dan McFate- discussed putting 90% furnace in existing location of electric furnace- gas there for water heater just need to veryify BTU to both appliances and sizing can be met- need R/A in side wall- combustion air high and low already there for water heater- exhaust and intake for furnace will come from roof- access needed big enough to remove appliance- make sure clearances are met per furnace manufactures installation manual- provide CO detectors if none are installed- condensate can go to floor drain in closet by water heater
|
MEC17-04695
| Pressure Test | 10/19/2017 | 10/20/2017 | 10/20/2017 2:50:14 PM | P | FAIL |
|
|
We are requesting a gas pressure test. Contact homeowner Jennifer: ###-#### Phone #: ###-#### Inspection requested via web by Rusty Karel- 20lb gas test pass- 60lb gas test failed gauge at 49psi
|
MEC17-04506
| Final | 10/17/2017 | 10/20/2017 | 10/20/2017 2:03:21 PM | P | PASS |
|
|
Final with pressure test. Please coordinate with Dwight ###-####. Thanks! Phone #: ###-#### Inspection requested via web by Rick Borg
|
MEC17-03772
| Final | 10/19/2017 | 10/20/2017 | 10/20/2017 1:23:12 PM | P | PASS |
|
|
Inspection requested via web by Jason Robinson
|
MEC17-03813
| Final | 10/19/2017 | 10/20/2017 | 10/20/2017 11:57:02 AM | A | PASS |
|
|
CLINT ###-#### Phone #: ###-#### Inspection requested via web by Jason Robinson
|
MEC17-04087
| Final | 10/20/2017 | 10/20/2017 | 10/20/2017 11:24:45 AM | A | PART |
|
|
need units fired up- need air balance done and air balance report onsite
|
MEC17-04087
| Rough-in | 10/19/2017 | 10/20/2017 | 10/20/2017 11:23:43 AM | A | PASS |
|
|
around 10 am- ###-####- 1st and 2nd floor ok for ceiling tile install in all areas
|
MEC17-04610
| Final | 10/17/2017 | 10/20/2017 | 10/20/2017 10:52:01 AM | A | FAIL |
|
|
Please call Robert Newman at ###-#### about 30-60 minutes prior to inspection Phone #: ###-#### Inspection requested via web by Mary LaFayette- need 15 amp breaker install in panel for A/C
|
MEC15-05932
| Mec-Aging Inspection | 10/20/2017 | 10/20/2017 | 10/20/2017 10:31:33 AM | | NH |
|
|
no one home- no access- left notice on front door
|
MEC15-02230
| Mec-Aging Inspection | 10/20/2017 | 10/20/2017 | 10/20/2017 10:01:19 AM | | CANC |
|
|
work in progress-
|
MEC17-02855
| Conference | 10/19/2017 | 10/20/2017 | 10/20/2017 9:42:14 AM | A | DONE |
|
|
go over gas piping tie in to existing 4"- ###-####- went over gas piping connection at meter location-
|
MEC16-05523
| Final | 10/19/2017 | 10/20/2017 | 10/20/2017 9:12:03 AM | A | PASS |
|
|
###-####- 830-9 am
|
MEC17-04485
| Pressure Test | 10/19/2017 | 10/20/2017 | 10/20/2017 8:25:54 AM | A | PASS |
|
|
Les Phone #: ###-####- 20lb gas pass whole system
|
MEC17-04691
| Final | 10/19/2017 | 10/20/2017 | 10/19/2017 2:48:18 PM | A | CANC |
|
|
Bj 2085730755 Inspection requested via web by william kerwin- did inspection on 10-19-17
|
MEC17-04506
| Pressure Test | 10/17/2017 | 10/20/2017 | 10/17/2017 3:35:53 PM | P | CANC |
|
|
Hello! Please call Dwight @ ###-#### to confirm job is ready for inspection.
Thanks! Phone #: ###-#### >> Inspection requested via web by Rick Borg Inspection cancelled from web by: Rick Borg
|