ELE09-00868
| ELE-Aging Inspection | 10/21/2013 | 10/21/2013 | 10/23/2013 7:22:11 AM | | CANC |
|
|
|
ELE10-00452
| ELE-Aging Inspection | 10/21/2013 | 10/21/2013 | 10/23/2013 7:21:45 AM | | CANC |
|
|
|
ELE09-02129
| ELE-Aging Inspection | 10/21/2013 | 10/21/2013 | 10/23/2013 7:21:22 AM | | CANC |
|
|
|
ELE13-02932
| Electrical Rough-In | 10/21/2013 | 10/21/2013 | 10/21/2013 3:01:48 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Terry Scott ri ok
|
ELE13-02912
| Rough-In Permanent Service | 10/20/2013 | 10/21/2013 | 10/21/2013 2:46:13 PM | P | PASS |
|
|
Call Dene with any questions Thank you Phone #: ###-#### >> Inspection requested via web by kim grundhauser no u/g house to garage seen, called, will open up some and call for inspection, jetted tub ok, ri ok, p/s u/g n ok
|
ELE13-02931
| Electrical Rough-In | 10/21/2013 | 10/21/2013 | 10/21/2013 1:51:23 PM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by John VanZandt called, left correction notice, NEC 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 314.20 in walls of combustible material, boxes shall be flush with finished surface, BCC shall add 2 rooms to permit
|
ELE13-02233
| Final | 10/21/2013 | 10/21/2013 | 10/21/2013 12:43:40 PM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Randy Fletcher called, corrections not made, left correction notice, NEC 250.64(E) shall bond each end metal raceway for grounding electrode conductor, shall call for p/s
|
MIS13-00225
| ELE-Conference | 10/18/2013 | 10/21/2013 | 10/21/2013 10:19:54 AM | A | DONE |
|
|
possible undergroud utilities talked to owner, structure was existing when purchased, will be converting to storage space, no electrical done, will be getting permit
|
ELE13-02921
| Electrical Rough-In | 10/18/2013 | 10/21/2013 | 10/21/2013 9:53:24 AM | A | PASS |
|
|
bonding inspection cover / light Phone #: ###-#### >> Inspection requested via web by Kevin Koomler ok pool bonding, light
|
ELE13-02315
| Electrical Rough-In | 10/18/2013 | 10/21/2013 | 10/21/2013 9:23:35 AM | A | PASS |
|
|
Contact: Tony Norton. ceiling inspection please Phone #: ###-#### >> Inspection requested via web by Deb Gooden ok cover ceilings
|
ELE13-01476
| Electrical Rough-In | 10/18/2013 | 10/21/2013 | 10/21/2013 8:50:31 AM | A | PASS |
|
|
Cody Phone #: ###-#### upstairs bath hardlids ok cover
|
ELE13-02925
| Electrical Rough-In | 10/20/2013 | 10/21/2013 | 10/21/2013 8:08:32 AM | A | PASS |
|
|
Electricians not on site. Please check in at front desk with receptionist for a visitors pass. Phone #: ###-#### >> Inspection requested via web by Steve McCloy ri ok, offices due north of reception desk
|