Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-01322 Final10/21/201410/21/201410/22/2014 11:28:43 AMPCANC
Finaled by mistake
ELE14-02818 Final10/17/201410/21/201410/21/2014 4:07:29 PMPPASS
JR Phone #: ###-####
Final OK kitchen
ELE14-02698 Permanent Service10/21/201410/21/201410/21/2014 3:33:32 PMPPASS
Inspect service to get power on Phone #: ###-#### Inspection requested via web by Stan Woodward

p/s, ug, n, ok
ELE14-02706 Electrical Rough-In10/20/201410/21/201410/21/2014 3:10:37 PMPPASS
This will be a wall rough-in inspection. Contact is Kyle Little ###-####.
Thank you and have a great day. Phone #: ###-#### Inspection requested via web by Laura Longshaw
bathrooms, storage areas, walls and hard lid ok to cover
ELE14-02939 Final10/21/201410/21/201410/21/2014 2:47:14 PMPPASS
Dan Phone #: ###-####
a/c final ok
ELE14-02939 Electrical Rough-In10/21/201410/21/201410/21/2014 2:46:55 PMPPASS
Dan Phone #: ###-#### a/c rough in ok
GCE14-00169 GCE-Rough-In10/21/201410/21/201410/21/2014 2:08:41 PMPPASS
Chad ###-#### call for access if needed rough in for ceiling and wall surface conduit requested
Back area of 108, surface mount conduit, boxes grounded
RI OK
GCE14-00163 GCE-Rough-In Permanent Service10/21/201410/21/201410/21/2014 1:50:45 PMPFAIL
Daniel ###-####
210.52(A)(2) Pocket door, and stair rail wall space shall have receptacle outlets, reading nook under stairs
300.4 NM and Low Volt cable through bored holes that do not maintain 1 1/4 inches from framing surface shall be protected from physical damage
300.4 B 1 Fireplace, nm cable shall enter through bushed hole
334.30 NM Cable shall be supported at integrals not exceeding 4.5 feet
334.30 do not stack staples, can damage cable
low volt wiring under truss
GCE14-00172 GCE-Rough-In10/20/201410/21/201410/21/2014 12:32:46 PMPPASS
Carl ###-#### WALLS Rough in ok to cover
GCE14-00034 GCE-Final10/17/201410/21/201410/21/2014 12:03:22 PMAPASS
Steven ###-#### call for access; Alan ###-#### contractor final ok
ELE14-02825 Electrical Rough-In10/20/201410/21/201410/21/2014 10:23:47 AMAPASS
Contact: Beau Cannon - wall rough-in please Phone #: ###-#### Inspection requested via web by Deb Gooden
wall r/I ok
ELE14-02924 Final10/20/201410/21/201410/21/2014 9:46:37 AMAPASS
Jason Gaythwaite is our journeyman Contact Phone #: ###-#### Inspection requested via web by Kelly Felin a/c final ok
ELE14-02924 Electrical Rough-In10/21/201410/21/201410/21/2014 9:45:09 AMPPASS
Jason Gaythwaite is our journeyman Contact Phone #: ###-#### Inspection requested via web by Kelly Felin a/c unit ok
ELE14-02925 Electrical Rough-In10/20/201410/21/201410/21/2014 9:22:28 AMAPASS
Gate on east side of house is open no dog''s , other side of garage Phone #: ###-#### Inspection requested via web by Jesse Fuentes
back patio, sunroom ok to cover. check heat/pump on final
ELE13-03546 Final10/20/201410/21/201410/21/2014 8:59:27 AMAPART
PARTIAL FINAL ON LIGHTING Phone #: ###-#### Hanger area ok to move in equipment. Check outlets for GFCI protection on final.