Inspections for the day of: Wednesday, October 21, 2015.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-00804 ELE-Aging Inspection10/21/201510/21/201510/26/2015 3:17:20 PM DONE
Still under construction
ELE15-02857 Final10/20/201510/21/201510/21/2015 2:30:33 PMPPASS
Phone #: ###-#### Inspection requested via web by Will Sevy Final ok
ELE15-01111 Electrical Rough-In10/20/201510/21/201510/21/2015 1:58:36 PMPPASS
WE need a ceiling inspection. Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker
This will complete grid areas. Misc tiles will be left out where open boxes noticed. Showroom grid rough in ok cover
ELE15-03163 Electrical Rough-In10/21/201510/21/201510/21/2015 1:16:31 PMPPASS
Underground Service Inspection. Contact Steve Hess. Phone #: ###-#### Inspection requested via web by Cathy Duchek
Underground from service to pad rough in ok cover
ELE15-03163 Permanent Service10/21/201510/21/201510/21/2015 12:45:49 PMPPASS
Underground Service Inspection. Contact Steve Hess. Phone #: ###-#### Inspection requested via web by Cathy Duchek
p/s u/g n ok
ELE15-03120 Final10/20/201510/21/201510/21/2015 12:38:29 PMAFAIL
We are requesting a final inspection for tomorrow 10/21/15. Our contact for this is Kory @###-####. Thank you,
Phone #: ###-#### Inspection requested via web by Clint Tate 210.8(B)(2)- All 120 volt 15 and 20 amp receptacle outlets located in commercial kitchens shall have GFCI protection.
406.6- Receptacle faceplates shall be installed to completely cover opening. 240 volt under counter to right of registers.
ELE15-03106 Conference10/19/201510/21/201510/21/2015 11:27:34 AMADONE
Phone #: ###-#### Inspection requested via web by Kelly Felin Discussed code requirements for upgrade of 480 volt service. 1200 amp, max number of handle throws for disconnecting means, 230.95(C)- required field test prior to permanent service inspection, verify grounding electode system, available fault current posting.
ELE15-02282 Final10/20/201510/21/201510/21/2015 10:53:49 AMAPASS
If you have any questions, please call Calvin ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan Final ok
ELE15-03048 Final10/20/201510/21/201510/21/2015 10:51:45 AMAPASS
If you have any questions, please call Calvin ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan Final ok
ELE15-02817 Electrical Rough-In10/20/201510/21/201510/21/2015 10:10:27 AMACANC
Grid ceiling Phone #: ###-#### Inspection requested via web by Lee VanSchoiack Grid rough in ok cover
ELE15-02816 Electrical Rough-In10/20/201510/21/201510/21/2015 10:09:43 AMAPASS
Grid ceiling Phone #: ###-#### Inspection requested via web by Lee VanSchoiack Grid rough in ok cover
ELE15-03113 Final10/20/201510/21/201510/21/2015 9:47:14 AMAPASS
Lock box number if needed is 1931 Phone #: ###-#### Inspection requested via web by Brad Baker Final ok
ELE15-03101 Final10/21/201510/21/201510/21/2015 9:19:47 AMAPASS
Phone #: ###-#### Inspection requested via web by Greg Traudt Final ok
ELE15-03384 Temporary Service10/20/201510/21/201510/21/2015 8:52:31 AMAPASS
electrical temporary, new construction Phone #: ###-#### Inspection requested via web by David Nelson t/s u/g n ok
ELE15-03383 Temporary Service10/20/201510/21/201510/21/2015 8:37:13 AMAPASS
Phone #: ###-#### Inspection requested via web by David Nelson t/s u/g n ok
ELE15-02816 Final10/20/201510/21/201510/20/2015 9:50:40 PMACANC
Grid ceiling Phone #: ###-#### >> Inspection requested via web by Lee VanSchoiack Inspection cancelled from web by: Lee VanSchoiack