Inspections for the day of: Tuesday, October 22, 2013.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-02924 Electrical Rough-In10/22/201310/22/201310/22/2013 1:34:40 PMPPASS
Dave Phone #: ###-#### rough-in ok cover
ELE13-02378 Final10/21/201310/22/201310/22/2013 1:02:25 PMPFAIL
We have made arrangement with Launa to be available on Tuesday afternoon she won''t be available until after 1:00. Please call her at ###-#### at least 30 minutes before you arrive and she will open the door for you. Thanks Phone #: ###-#### >> Inspection requested via web by Celinda Winters NEC 408.7 service panel requires directory
ELE13-01271 Final10/22/201310/22/201310/22/2013 12:53:35 PMPPASS
DERK Phone #: ###-#### job complete, final ok
ELE13-02574 Electrical Rough-In10/22/201310/22/201310/22/2013 12:36:18 PMPPASS
Contact is Dean Gernaat. Thank you and have a super day! Phone #: ###-#### >> Inspection requested via web by Camille Gulley Rough-in ok cover new receptacles in kitchen walls
ELE13-00837 Electrical Rough-In10/22/201310/22/201310/22/2013 12:21:30 PMPPASS
underground conduit - Mark Phone #: ###-#### rough-in ok cover underground at exsiting dispenser location
ELE13-02209 Final10/22/201310/22/201310/22/2013 12:19:09 PMPNR
They are still finishing the offices so they may have removed our plates. We can make sure they get reinstalled Phone #: ###-#### >> Inspection requested via web by Caleb Wheeler Not ready for final
ELE13-02902 Electrical Rough-In10/21/201310/22/201310/22/2013 10:43:41 AMAPASS
Contact: Justin Hugo Phone #: ###-#### >> Inspection requested via web by Deb Gooden Rough-in ok cover walls in office addition, access- mandoor west end by roll up
ELE13-01173 Final10/22/201310/22/201310/22/2013 10:12:43 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Neil Adams correction done, final ok
ELE13-02935 Permanent Service10/21/201310/22/201310/22/2013 9:46:52 AMAPASS
lock box code 1114 Phone #: ###-#### >> Inspection requested via web by Dan Rohl p/s u/g rec ok
ELE13-01271 Final10/21/201310/22/201310/22/2013 9:29:21 AMAFAIL
Dirk Phone #: ###-#### NEC 422.51 Cord and plug connected vending machines shall have GFCI protection, Repour sealoffs as needed
ELE13-02395 Permanent Service10/21/201310/22/201310/22/2013 8:33:01 AMADONE
Owner: Kevin Loyd ###-#### >> Inspection requested via web by Danny Perrine Gas meter set within 36 inch minimum distance of service gear, Gas company requirement, not in the National Electrical Code
ELE13-02378 Final10/18/201310/22/201310/21/2013 3:51:46 PMACANC
We have made arrangements with Launa to be available on Tuesday morning - you can call her at ###-#### 30 minutes before you arrive and she will open the door for you. Thanks!!!! Phone #: ###-#### >> Inspection requested via web by Celinda Winters Inspection cancelled from web by: Celinda Winters
ELE12-02780 Final10/21/201310/22/201310/21/2013 1:58:07 PMAPASS
Karl Phone #: ###-#### final ok