BLD13-00544
| BLD-Framing/Rough-in | 10/21/2013 | 10/22/2013 | 10/22/2013 4:42:32 PM | P | PART |
|
|
Phone #: ###-#### >> Inspection requested via web by Brian Stark. Remove non rated box from 1hr. wall. Complete airseal at missed locations. Pending electrical rough in inspection.
|
BLD13-00556
| BLD-Framing/Rough-in | 10/21/2013 | 10/22/2013 | 10/22/2013 4:41:12 PM | P | PART |
|
|
Phone #: ###-#### >> Inspection requested via web by Brian Stark. Provide approved repair for broken floor truss. Pending mechanical rough in inspection.
|
BLD13-00552
| BLD-Framing/Rough-in | 10/21/2013 | 10/22/2013 | 10/22/2013 4:39:49 PM | P | PART |
|
|
Phone #: ###-#### >> Inspection requested via web by Brian Stark. Provide floor truss repair at stairs from truss engineer. Complte airseal pack at missed locations. Pending mechanical rough in inspection.
|
BLD13-00550
| BLD-Framing/Rough-in | 10/21/2013 | 10/22/2013 | 10/22/2013 4:37:28 PM | P | PART |
|
|
Phone #: ###-#### >> Inspection requested via web by Brian Stark. Provide truss engineering. Ok to insulate after mech. rough in inspection.
|
ESC13-00238
| General Inspection | 10/22/2013 | 10/22/2013 | 10/22/2013 4:34:14 PM | P | PASS |
|
|
|
BLD13-00558
| BLD-Framing/Rough-in | 10/21/2013 | 10/22/2013 | 10/22/2013 4:33:50 PM | P | NR |
|
|
Phone #: ###-#### >> Inspection requested via web by Brian Stark. Airseal pack not completed.
|
BLD13-01289
| BLD-Conference | 10/22/2013 | 10/22/2013 | 10/22/2013 4:22:23 PM | P | DONE |
|
|
Phone #: ###-#### >> Inspection requested via web by Mike McHargue
|
BLD13-01287
| BLD-Wall Bracing | 10/22/2013 | 10/22/2013 | 10/22/2013 4:20:41 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Mike McHargue
|
BLD13-02352
| BLD-Framing/Rough-in | 10/22/2013 | 10/22/2013 | 10/22/2013 4:19:10 PM | P | PASS |
|
|
James Phone #: ###-####
|
BLD13-02208
| BLD-Final | 10/22/2013 | 10/22/2013 | 10/22/2013 11:40:03 AM | P | PASS |
|
|
Phone #: 208869911 >> Inspection requested via mobile web by Carrie. ok for perm occ.
|
ESC13-00751
| Random Inspection | 10/22/2013 | 10/22/2013 | 10/22/2013 11:38:00 AM | A | PART |
|
|
Needs to sweep silts from hard surfaces. RP notified.
|
BLD13-02050
| BLD-Wall Bracing | 10/21/2013 | 10/22/2013 | 10/22/2013 11:35:34 AM | A | PART |
|
|
Phone #: ###-#### >> Inspection requested via web by Brian Stark. 1st. story only.
|
ESC13-00757
| Random Inspection | 10/22/2013 | 10/22/2013 | 10/22/2013 11:33:32 AM | A | PART |
|
|
Needs to swepp silts from hard surfaces. RP notified.
|
BLD13-02054
| BLD-Wall Bracing | 10/21/2013 | 10/22/2013 | 10/22/2013 11:32:32 AM | A | PART |
|
|
Phone #: ###-#### >> Inspection requested via web by Brian Stark. 1st. story only.
|
BLD13-02007
| BLD-Final | 10/21/2013 | 10/22/2013 | 10/22/2013 10:01:51 AM | A | CANC |
|
|
trey - Phone #: ###-####. per contractor, rescheduled for Wed.
|
ESC13-00654
| General Inspection | 10/22/2013 | 10/22/2013 | 10/22/2013 10:00:09 AM | A | PASS |
|
|
|
BLD13-01808
| BLD-Framing/Rough-in | 10/21/2013 | 10/22/2013 | 10/22/2013 9:59:36 AM | A | NR |
|
|
paul Phone #: ###-####. Needs mechanical rough in inspection. Mechanical work not yet completed.
|
ESC13-00777
| Site Preparation | 10/22/2013 | 10/22/2013 | 10/22/2013 9:40:33 AM | A | FAIL |
|
|
POst ESC permit sign, a site inspection is required prior to any excavation being done. Install all required BMP's per plan, provide concrete washout, install DI protection, provide BMP for allready excavated soils on hard surfaces. Correction notice was posted.
|
BLD13-02102
| BLD-Footing | 10/21/2013 | 10/22/2013 | 10/22/2013 9:38:37 AM | A | FAIL |
|
|
John MIller Phone #: ###-####. Provide additional chairs on north footing line to provide the min. required clearances. Provide RFI from engineer for change in field conditions for connection to existing footing. Provide specified conc psi to be used and concrete design psi by engineer. Correction notice posted. Also noted ESC issues. No concrete allowed at this time.
|
BLD13-00335
| BLD-Wall Bracing | 10/21/2013 | 10/22/2013 | 10/21/2013 7:33:08 PM | A | CANC |
|
|
Mike. I will be out of town for a funeral. Left a message with Aggregate about missing straps. My framer mentioned you would come back for shear inspection tomorrow AM, but didn''t know if you wanted to wait until the holdowns were fixed. Phone #: ###-#### >> Inspection requested via web by Scott Zierler Inspection cancelled from web by: Scott Zierler
|