ELE13-00842
| ELE-Aging Inspection | 10/22/2015 | 10/22/2015 | 10/26/2015 3:19:08 PM | | DONE |
|
|
Waiting on contractor
|
ELE15-02315
| Final | 10/21/2015 | 10/22/2015 | 10/22/2015 3:54:33 PM | P | FAIL |
|
|
Final Inspection Electrician is Darby Talbot Contact Shari @ ###-#### for access. Phone #: ###-#### Inspection requested via web by Cathy Duchek 210.52- Receptacle outlet spacing for a habitable room shall not exceed 6' from a receptacle measured along floor line. Buried outlet
|
ELE15-00089
| Electrical Rough-In | 10/22/2015 | 10/22/2015 | 10/22/2015 2:18:13 PM | P | PASS |
|
|
Call prior to going Phone #: 2083520355 >> Inspection requested via mobile web by Dan monzo Garage panel wall rough in ok cover
|
ELE15-03400
| Electrical Rough-In | 10/22/2015 | 10/22/2015 | 10/22/2015 1:41:26 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov 300.4- NM cable shall be protected from physical damage where ran through bored holes that do not maintain 1 1/4" from framing surface. 300.13- For multiwire branch circuits continuity of a grounded conductor shall not depend on device connections. 334.30- NM cable shall not be secured with in 1 1/4" from framing surface.
|
ELE15-02836
| Final | 10/22/2015 | 10/22/2015 | 10/22/2015 12:43:01 PM | P | PASS |
|
|
READY NOW ANY ? CALL BILL ###-#### Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
ELE15-02610
| Final | 10/22/2015 | 10/22/2015 | 10/22/2015 12:38:42 PM | P | PASS |
|
|
READY NOW ANY ? CALL BILL ###-#### Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
ELE15-03397
| Final | 10/21/2015 | 10/22/2015 | 10/22/2015 11:14:05 AM | A | PASS |
|
|
Customer''s name is Richard and he will be home in the morning. His # is ###-####. Call me if you have any questions. Kevin R.E. Phone #: ###-#### Inspection requested via web by Kevin Cowgill Final ok
|
ELE15-03345
| Final | 10/20/2015 | 10/22/2015 | 10/22/2015 10:36:03 AM | A | FAIL |
|
|
Allen Phone #: ###-#### BCC 4-05-32- Code violations not to be retained. 400.8- Flexible cords shall not be used and a substitute for fixed wiring of a structure. Cord that plugs into wall runs up wall to top of beam across to track light in living room.
|
ELE15-03071
| Final | 10/21/2015 | 10/22/2015 | 10/22/2015 10:08:51 AM | A | FAIL |
|
|
please contact jeff @ ###-#### for questions about job Phone #: ###-#### Inspection requested via web by Andrea Creek 400.8- Flexible cords shall not run through holes in walls. 400.14- Flexible cord shall be protected by bushing or fitting where ran through holes in cover. Split system
|
ELE15-03120
| Final | 10/21/2015 | 10/22/2015 | 10/22/2015 9:34:08 AM | A | PASS |
|
|
We are requesting a final inspection on this project for tomorrow in the AM. Our contact is Kory @ ###-####. Thank you, Phone #: ###-#### Inspection requested via web by Clint Tate Questioned location of GFCI receptacles. Contractor stated all equipment will be on counter tops so GFCI receptacles all readily accessible at time of final. Final ok
|
ELE15-02538
| Final | 10/21/2015 | 10/22/2015 | 10/22/2015 9:12:30 AM | A | PASS |
|
|
fence bonding Phone #: ###-#### Inspection requested via web by cory carman No card posted. Final ok
|
ELE15-03390
| Temporary Service | 10/21/2015 | 10/22/2015 | 10/22/2015 8:30:56 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Richard Gratiot t/s u/g n ok
|