ELE12-02998
| ELE-Aging Inspection | 10/22/2018 | 10/22/2018 | 10/23/2018 3:43:25 PM | | PASS |
|
|
Drove by and posted correction notice explaining several attempts have been made to contact contractor to schedule. Dave called and explained house has sold to new owners.
|
ELE18-02542
| Final | 10/22/2018 | 10/22/2018 | 10/22/2018 3:42:40 PM | P | FAIL |
|
|
Corbin ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg 210.8- Receptacle serving hutch counter top shall have GFCI protection. 210.52(B)(2)- Kitchen appliance circuits shall have no other outlets. Over sink and under cabinet lighting on with kitchen appliance. 210.52(C)- Receptacle outlets shall be located with in 24" of each side of kitchen sink. 314.20- Boxes mounted in a combustible wall material shall have an extension ring installed flush with surface. Appliance garage, hutch, disposal.
|
ELE18-03802
| Electrical Rough-In | 10/22/2018 | 10/22/2018 | 10/22/2018 2:31:59 PM | P | PASS |
|
|
Randy. Wall cover. Phone #: ###-#### Inspection requested via web by Sean DeLacy North and west exterior office walls only rough in ok cover
|
ELE18-02479
| Electrical Rough-In | 10/22/2018 | 10/22/2018 | 10/22/2018 1:47:37 PM | P | PART |
|
|
Ceiling rough in inspection for level 10 at the One Capital building Please contact electrician on site Jon Novak Thank you Phone #: ###-#### Inspection requested via web by Cathy Duchek Open office areas grid rough in ok cover
|
ELE18-04050
| Permanent Service | 10/21/2018 | 10/22/2018 | 10/22/2018 10:09:51 AM | A | PASS |
|
|
Building is unlocked. Branch panel in room C-1. Solar will be tied in at later date. #6 Bonding jumper installed between frames. Portable building is located in the backyard of the school. Phone #: ###-#### Inspection requested via web by Sean Patton Entrance off Phillippi. p/s u/g n ok
|
ELE18-03977
| Final | 10/18/2018 | 10/22/2018 | 10/22/2018 9:41:55 AM | A | PASS |
|
|
Please call owner Brandon Rex before heading over. Thanks Phone #: ###-#### Inspection requested via web by steve ragan Final ok
|
ELE18-03977
| Electrical Rough-In | 10/22/2018 | 10/22/2018 | 10/22/2018 9:41:46 AM | P | PASS |
|
|
Please call owner Brandon Rex before heading over. Thanks Phone #: ###-#### Inspection requested via web by steve ragan New circuits for AC service receptacle and gas furnace rough in ok
|
ELE18-03623
| Electrical Rough-In | 10/19/2018 | 10/22/2018 | 10/22/2018 7:31:02 AM | A | CANC |
|
|
Rough in new master suite addition in back. Home owner will be there. Phone #: ###-#### >> Inspection requested via web by David McClellan Inspection cancelled from web by: David McClellan
|