Inspections for the day of: Tuesday, October 22, 2019.
Number of inspections: 24
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-04772 Final10/22/201910/22/201910/22/2019 4:09:02 PMPNH
Sara Phone #: ###-####
- no access left notice on front door
MEC15-01675 Rough-in10/22/201910/22/201910/22/2019 3:41:43 PMPPASS
Jason Phone #: ###-####
- R/I ok
- owner will keep sheetrock lid off where boiler flue goes outside. Still need to see 5lb flue pressure test on boiler
MEC19-04272 Rough-in10/18/201910/22/201910/22/2019 3:11:51 PMPPART
Please contact Brian Eddins with any questions at ###-####. Phone #: ###-#### Inspection requested via web by Josh Bennett
2-fire/smoke damper clearances ok for retaining angles
- duct seal R/I ok for insulation
MEC19-04748 Final10/21/201910/22/201910/22/2019 3:09:15 PMPPASS
Please call Jeremy on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- final ok
MEC19-04728 Final10/18/201910/22/201910/22/2019 2:24:22 PMPPASS
INSTALLER DUSTIN ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- furnace only co ok
MEC19-04727 Final10/18/201910/22/201910/22/2019 2:24:04 PMPPASS
INSTALLER DUSTIN ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- furnace only co ok
MEC19-04654 Final10/21/201910/22/201910/22/2019 1:44:25 PMPNR
Please call Craig on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
-not ready
- need to also see electrical permit for ductless
MEC19-04591 Final10/21/201910/22/201910/22/2019 12:11:11 PMAPART
Called Intermountain Gas and verified meter was large enough. They said it was but they would swing by tomorrow to verify the spring. The gas pipe is 1 1/4 all the way to the crawl and then reduces to 1" then 3/4 to tankless. Phone #: ###-#### Inspection requested via web by Aaron Alandt
- need verification from gas company on meter being sized for load
- if gas piping system is being updated to a high pressure system need to see a 60lb gas pressure test and regulators installed
MEC19-04498 Rough-in10/21/201910/22/201910/22/2019 11:59:42 AMAPASS
Call Kyle Korb at ###-#### with questions or concerns. Phone #: ###-#### Inspection requested via web by Ashley Shoecraft
2- fireplace R/I ok
MEC19-04451 Final10/15/201910/22/201910/22/2019 11:42:55 AMAPASS
Please call Susan prior to arrival. Phone #: ###-#### Inspection requested via web by Andrea Grigsby
- furnace ac coil co ok
MEC19-04765 Pressure Test10/21/201910/22/201910/22/2019 11:23:42 AMAFAIL
Call for access- Ranee Phone #: ###-####
- need to see a pressure test on underground gas line
- gas line under ground needs to be an approved material
- gas line penetrations into shop needs 10 mill tape installed
- add bathroom exhaust fan and unit heater to permit
MEC19-04780 Pressure Test10/22/201910/22/201910/22/2019 11:09:07 AMPCANC
Call Jason @ ###-#### with any issues. Phone #: ###-#### >> Inspection requested via web by Angie Maguire Inspection cancelled from web by: Angie Maguire
MEC19-04780 Rough-in10/22/201910/22/201910/22/2019 11:09:05 AMPCANC
Call Jason @ ###-#### with any issues. Phone #: ###-#### >> Inspection requested via web by Angie Maguire Inspection cancelled from web by: Angie Maguire
MEC19-03896 Final10/15/201910/22/201910/22/2019 10:33:34 AMAFAIL
Please call Lynette in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout
- coil ok
- A/C needs locking caps installed on service ports
MEC19-04187 Final10/15/201910/22/201910/22/2019 9:56:56 AMAFAIL
Please call Karen in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout
- furnace coil ok
- A/C needs locking caps installed on service ports
MEC19-04758 Rough-in10/21/201910/22/201910/22/2019 9:43:31 AMAPART
Phone #: ###-#### Inspection requested via web by Sheldon Lebow
- 1st floor fireplaces not ready
-2nd floor fireplaces 4 units fireplaces ok
- 3rd floor fireplaces not ready
MEC19-04754 Pressure Test10/21/201910/22/201910/22/2019 8:48:16 AMAPASS
PLEASE CALL OUR LEAD INSTALLER HARLEY WHO WILL ALREADY BE ONSITE WHEN YOU ARRIVE- PRESSURE TEST ONLY Phone #: ###-#### Inspection requested via web by Rick Montgomery
- 20lb gas pressure test ok
- tagged meter location
MEC18-00299 Mec-Aging Inspection10/22/201910/22/201910/22/2019 8:07:32 AM PASS
WIP
MEC19-01236 Mec-Aging Inspection10/22/201910/22/201910/22/2019 8:07:13 AM PASS
Doc Permit Final ok
MEC19-01236 DOC - Permit Finaled10/22/201910/22/201910/22/2019 8:06:58 AMAPASS
Doc Permit Final ok
MEC19-01233 Mec-Aging Inspection10/22/201910/22/201910/22/2019 8:06:19 AM PASS
Doc Permit Final ok
MEC19-01233 DOC - Permit Finaled10/22/201910/22/201910/22/2019 8:01:52 AMAPASS
Doc Permit Final ok
MEC19-01267 Mec-Aging Inspection10/22/201910/22/201910/22/2019 7:56:31 AM PASS
Doc Permit Final ok
MEC19-01267 DOC - Permit Finaled10/22/201910/22/201910/22/2019 7:56:17 AMAPASS
Doc Permit Final ok