Inspections for the day of: Tuesday, October 23, 2001.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBill VanDegrift
TitlePLM-INSPECTOR
Phone #794-9372
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM01-00433 PLM-Aging Inspection10/23/200110/23/200110/23/2001 12:00:00 AM NR
BLD01-01316 BLD-Conference10/23/200110/23/200110/23/2001 12:00:00 AMAFAIL
Added by Inspector: 330 On 10/23/2001 8:56:19 AM need test on exterior rain water piping
PLM01-03549 Plumbing Rough-in10/23/200110/23/200110/23/2001 12:00:00 AMAPASS
Added by Inspector: 330 On 10/23/2001 10:08:46 AM
PLM01-03522 Plumbing Rough-in10/22/200110/23/200110/23/2001 12:00:00 AMAFAIL
Scheduled by a contractor via Hello! on 10/22/2001 at 19:49:45. Contact: ###-####. turn vent santees the right dirrection, hang waste every 4', water every 32", NO WASTE CONNECTION ALLOWED ON A CLOSET ARM, ROLL VENTS ABOVE FLOWLINE, C.O. REQUIRED ON ISLAND SINK VENT, TESTS REQUIRED. 10/23/2001 9:44:24 AM
PLM01-03646 Water and/or Sewer10/23/200110/23/200110/23/2001 12:00:00 AMPPART
Added by Inspector: 330 On 10/23/2001 2:12:10 PM sewer service ok needs to set end of the line manhole
PLM01-02203 Final10/23/200110/23/200110/23/2001 12:00:00 AMPFAIL
###-#### bill I need a sprinkler permit and inspection prior to a final inspection, test dcva 10/23/2001 2:05:29 PM
PLM01-03635 Water and/or Sewer10/23/200110/23/200110/23/2001 12:00:00 AMPPART
###-#### KEITH final ok when bedded in clean fill(they said they would) and tied into the system in the crawlspace 10/23/2001 1:31:44 PM
PLM01-03625 Plumbing Rough-in10/23/200110/23/200110/23/2001 12:00:00 AMPPART
partial gw ok, restrooms, janitor room, sink, needs utility room 10/23/2001 8:53:25 AM