ELE08-00026
| Final | 10/23/2008 | 10/23/2008 | 10/23/2008 3:40:12 PM | P | PASS |
|
|
ken Phone #: ###-#### ok
|
ELE08-02859
| Final | 10/23/2008 | 10/23/2008 | 10/23/2008 3:24:34 PM | P | PASS |
|
|
final on service upgrade any questions call Jimmy @ ###-#### Phone #: ###-#### Internet Inspection Request from: Andy Rose ok
|
ELE08-02091
| Final | 10/23/2008 | 10/23/2008 | 10/23/2008 1:50:29 PM | P | PASS |
|
|
mike Phone #: ###-#### ok
|
ELE08-01415
| Final | 10/23/2008 | 10/23/2008 | 10/23/2008 1:15:12 PM | P | FAIL |
|
|
Any questions please call Clay. House will be open. Thank you. Phone #: ###-#### Internet Inspection Request from: Clay Morgan corr called gfci for laundry recept in bathroom, outside back gfci box loose, needs access per manufacture's instructions for j-tub, box in upper kit cabinet shall be flush, and accessible shall not run cord used as fixed wiring for under cabinet fixtures kit, 210.52(C)(5) recept shall be above counter left of appliance garage kit
|
ELE08-02626
| Electrical Rough-In | 10/21/2008 | 10/23/2008 | 10/23/2008 12:23:31 PM | P | FAIL |
|
|
rough in inspection for adding (2) circuits.If possible, please final also. office # ###-#### electrician - bruce ###-#### Phone #: ###-#### Internet Inspection Request from: Carla Ward called no access
|
ELE08-01809
| Final | 10/22/2008 | 10/23/2008 | 10/23/2008 10:24:41 AM | A | FAIL |
|
|
kathy - please call for access Phone #: ###-#### corr fee due called contr has 4 working days to correct violations, 110.26(F)(2) remove plant, sprinkler equipment, and curb shall provide 36" for clearence in front of p/s, 408.4 label all circuits in panels where is furnace circuit?, 210.52(B&C) needs outlet for countertop space left of kit sink, 210.8 needs gfci for outlet left of range, needs inuse covers all outside recepts, 422.31 needs lockout clip for furnace breaker upstairs unit
|
ELE08-02557
| Permanent Service | 10/22/2008 | 10/23/2008 | 10/23/2008 9:21:30 AM | A | PASS |
|
|
Disconnect South side pole lights Phone #: ###-#### Internet Inspection Request from: Joe Thomas p/s u/g new ok
|
ELE08-02557
| Final | 10/23/2008 | 10/23/2008 | 10/23/2008 9:21:15 AM | A | PASS |
|
|
Disconnect South side pole lights Phone #: ###-#### Internet Inspection Request from: Joe Thomas
|
ELE08-02865
| Permanent Service | 10/22/2008 | 10/23/2008 | 10/23/2008 9:20:50 AM | A | PASS |
|
|
Disconnect east side pole lights Phone #: ###-#### Internet Inspection Request from: Joe Thomas p/s u/g new ok
|
ELE08-02865
| Final | 10/23/2008 | 10/23/2008 | 10/23/2008 9:20:33 AM | A | PASS |
|
|
Disconnect east side pole lights Phone #: ###-#### Internet Inspection Request from: Joe Thomas
|
ELE08-02864
| Permanent Service | 10/22/2008 | 10/23/2008 | 10/23/2008 9:20:10 AM | A | PASS |
|
|
Disconnect north side pole lights Phone #: ###-#### Internet Inspection Request from: Joe Thomas p/s u/g new ok
|
ELE08-02864
| Final | 10/23/2008 | 10/23/2008 | 10/23/2008 9:19:53 AM | A | PASS |
|
|
Disconnect north side pole lights Phone #: ###-#### Internet Inspection Request from: Joe Thomas
|
ELE08-02626
| Electrical Rough-In | 10/23/2008 | 10/23/2008 | 10/23/2008 12:00:00 AM | P | CANC |
|
|
|