Inspections for the day of: Thursday, October 23, 2008.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-00026 Final10/23/200810/23/200810/23/2008 3:40:12 PMPPASS
ken Phone #: ###-#### ok
ELE08-02859 Final10/23/200810/23/200810/23/2008 3:24:34 PMPPASS
final on service upgrade any questions call Jimmy @ ###-#### Phone #: ###-#### Internet Inspection Request from: Andy Rose ok
ELE08-02091 Final10/23/200810/23/200810/23/2008 1:50:29 PMPPASS
mike Phone #: ###-#### ok
ELE08-01415 Final10/23/200810/23/200810/23/2008 1:15:12 PMPFAIL
Any questions please call Clay. House will be open. Thank you. Phone #: ###-#### Internet Inspection Request from: Clay Morgan corr called gfci for laundry recept in bathroom, outside back gfci box loose, needs access per manufacture's instructions for j-tub, box in upper kit cabinet shall be flush, and accessible shall not run cord used as fixed wiring for under cabinet fixtures kit, 210.52(C)(5) recept shall be above counter left of appliance garage kit
ELE08-02626 Electrical Rough-In10/21/200810/23/200810/23/2008 12:23:31 PMPFAIL
rough in inspection for adding (2) circuits.If possible, please final also. office # ###-####
electrician - bruce ###-#### Phone #: ###-#### Internet Inspection Request from: Carla Ward called no access
ELE08-01809 Final10/22/200810/23/200810/23/2008 10:24:41 AMAFAIL
kathy - please call for access Phone #: ###-#### corr fee due called contr has 4 working days to correct violations, 110.26(F)(2) remove plant, sprinkler equipment, and curb shall provide 36" for clearence in front of p/s, 408.4 label all circuits in panels where is furnace circuit?, 210.52(B&C) needs outlet for countertop space left of kit sink, 210.8 needs gfci for outlet left of range, needs inuse covers all outside recepts, 422.31 needs lockout clip for furnace breaker upstairs unit
ELE08-02557 Permanent Service10/22/200810/23/200810/23/2008 9:21:30 AMAPASS
Disconnect South side pole lights Phone #: ###-#### Internet Inspection Request from: Joe Thomas p/s u/g new ok
ELE08-02557 Final10/23/200810/23/200810/23/2008 9:21:15 AMAPASS
Disconnect South side pole lights Phone #: ###-#### Internet Inspection Request from: Joe Thomas
ELE08-02865 Permanent Service10/22/200810/23/200810/23/2008 9:20:50 AMAPASS
Disconnect east side pole lights Phone #: ###-#### Internet Inspection Request from: Joe Thomas p/s u/g new ok
ELE08-02865 Final10/23/200810/23/200810/23/2008 9:20:33 AMAPASS
Disconnect east side pole lights Phone #: ###-#### Internet Inspection Request from: Joe Thomas
ELE08-02864 Permanent Service10/22/200810/23/200810/23/2008 9:20:10 AMAPASS
Disconnect north side pole lights Phone #: ###-#### Internet Inspection Request from: Joe Thomas p/s u/g new ok
ELE08-02864 Final10/23/200810/23/200810/23/2008 9:19:53 AMAPASS
Disconnect north side pole lights Phone #: ###-#### Internet Inspection Request from: Joe Thomas
ELE08-02626 Electrical Rough-In10/23/200810/23/200810/23/2008 12:00:00 AMPCANC