Inspections for the day of: Friday, October 23, 2015.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-02683 Final10/23/201510/23/201510/23/2015 4:12:31 PMPPASS
call if there is a provblem Phone #: ###-#### Inspection requested via web by Tracy Robertson Final ok
ELE15-02423 Final10/23/201510/23/201510/23/2015 3:30:27 PMPPASS
call if there is a problem Phone #: ###-#### Inspection requested via web by Tracy Robertson Final ok
ELE15-03400 Electrical Rough-In10/23/201510/23/201510/23/2015 2:50:58 PMPPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov Rough in ok cover
ELE15-03402 Electrical Rough-In10/22/201510/23/201510/23/2015 2:32:24 PMPPASS
Contact on site is Mike. Phone #: ###-#### Inspection requested via web by Todd Sellman West wall, mixing room, under slab rough in ok cover
ELE15-03396 Rough-In Permanent Service10/22/201510/23/201510/23/2015 2:11:29 PMPPASS
We need an underground inspection. Thank you!
Please contact Danny at the number listed Phone #: ###-#### Inspection requested via web by Stacie Tasker Electical room underground rough in ok cover
ELE15-03121 Final10/23/201510/23/201510/23/2015 2:00:14 PMPFAIL
Contact Ben @ ###-#### Phone #: ###-#### Inspection requested via web by Kristopher Wilson 314.25- All boxes shall have covers. Covers have been removed wall being painted at time of inspection. Will recall when finished.
ELE15-02315 Final10/23/201510/23/201510/23/2015 1:40:00 PMPPASS
Re-inspection. Outlet spacing /unburied remedied situation.
Contact Shari @ ###-#### for access.
Electrician Darby Talbot.
Phone #: ###-#### Inspection requested via web by Cathy Duchek Final ok
ELE15-03414 Final10/23/201510/23/201510/23/2015 1:17:12 PMPCANC
Phone #: ###-#### Inspection requested via web by Dan Rohl Needed temp service inspection
ELE15-03414 Temporary Service10/23/201510/23/201510/23/2015 1:15:42 PMPPASS
Phone #: ###-#### Inspection requested via web by Dan Rohl t/s u/g n ok
ELE15-03415 Conference10/23/201510/23/201510/23/2015 1:14:32 PMPCANC
underground Phone #: ###-#### Inspection requested via web by Dan Rohl Needed underground inspection
ELE15-03415 Electrical Rough-In10/23/201510/23/201510/23/2015 1:14:09 PMPPASS
underground Phone #: ###-#### Inspection requested via web by Dan Rohl
Underground for post light rough in ok cover
ELE15-02521 Final10/23/201510/23/201510/23/2015 1:12:59 PMPPASS
Inspection requested via web by Dan Rohl Final ok
ELE15-03137 Final10/22/201510/23/201510/23/2015 12:43:32 PMAFAIL
Phone #: ###-#### Inspection requested via web by Jim Williams
408.37- Panelboard installed outdoors in damp location shall have cover to prevent moisture from entering.
547.6- Receptacle outlets shall have enclosure to prevent entry of dust.
547.7- Motor for garage door opener shall be totally enlosed to prevint dust entry.
547.8- Luminaires in hay storage area shall be type to prevent entry of dust.
ELE15-01812 Rough-In Permanent Service10/22/201510/23/201510/23/2015 10:40:01 AMAPASS
Tate-underground-matt washer & south vacuums Phone #: ###-#### Underground southside vac area around to west rough in ok cover. No service inspection at this time
ELE15-02909 Final10/22/201510/23/201510/23/2015 10:01:46 AMAPASS
We are requesting a final inspection for tomorrow 10/23/15 in the AM. Our contact is Rich ###-#### or Cary @ ###-####. Thank you Phone #: ###-#### Inspection requested via web by Clint Tate
Access provided for transformer above grid. Final ok
ELE15-02821 Final10/22/201510/23/201510/23/2015 9:04:24 AMAFAIL
Garage code is 1234 Phone #: ###-#### Inspection requested via web by Richard Gratiot
410.10(D)- Master shower can. Exposed lamp located in shower stall shall be rated for wet location.
BCC- A minimum of 50% of lamps installed in residence shall be high efficiency lamps.
Called contact, no answer, no voicemail set up, unable to leave message