PLM17-04084
| Plumbing Rough-in | 10/23/2017 | 10/23/2017 | 10/23/2017 4:44:59 PM | P | PASS |
|
|
will be ready this afternoon Phone #: ###-#### Inspection requested via web by Troy Paulin
|
PLM17-03951
| Final | 10/20/2017 | 10/23/2017 | 10/23/2017 4:25:13 PM | P | PASS |
|
|
please call homeowner Pam ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss
|
PLM17-03903
| Final | 10/23/2017 | 10/23/2017 | 10/23/2017 3:59:19 PM | P | PASS |
|
|
For questions or concerns please call Buck at the number above. Phone #: ###-#### Inspection requested via web by Ben Davis
|
PLM17-04056
| Final | 10/19/2017 | 10/23/2017 | 10/23/2017 3:07:48 PM | P | FAIL |
|
|
Please inspect the back flow. Please contact Ken Register at ###-#### if you have any questions. Thank you!! Phone #: ###-#### Inspection requested via web by Franz Witte. Not cerified.. Second trip
|
PLM17-04005
| Final | 10/19/2017 | 10/23/2017 | 10/23/2017 2:26:58 PM | P | PASS |
|
|
Please call Jackie Coppola at ###-#### prior to inspection - she has dogs. Phone #: ###-#### Inspection requested via web by Mary LaFayette
|
PLM17-02698
| Plumbing Rough-in | 10/20/2017 | 10/23/2017 | 10/23/2017 12:33:08 PM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen. 1. The water lines are undersized on the hot and cold sides. 2. Nail plate protect all pipes with proper protection. 3. DWV pressure test failed. 4. The Master bath lav trap arm is too long. 5. Strap all water line sub-outs. 6. Install pipe insulators on the water lines going through studs. 7. Isolate all water lines from concrete.
|
PLM17-04078
| Sprinkler (Final) | 10/20/2017 | 10/23/2017 | 10/23/2017 11:48:14 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Warren Ponder
|
PLM17-04080
| Groundwork | 10/20/2017 | 10/23/2017 | 10/23/2017 11:06:17 AM | A | FAIL |
|
|
Kevin Phone #: ###-#### 1. Pipes are flat and backgrading. Install with a 1/4 per foot grade. 2. Extend the drain outside the house. 3. Wrap all piping in contact with the cement.
|
PLM17-04082
| Plumbing Rough-in | 10/20/2017 | 10/23/2017 | 10/23/2017 10:34:09 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by PATTY KIRK
|
PLM17-03869
| Water and/or Sewer | 10/23/2017 | 10/23/2017 | 10/23/2017 9:51:36 AM | A | FAIL |
|
|
THIS WAS CALLED IN ON THE GRADING PERMIT GRD17-00025 Jim Wellman
Requesting an inspection for 1500 gallon grease interceptor. Not sure what type of inspection is needed. I talked to Dan Ediger Plumbing inspector looked at it and need him to re-inspect tank. Phone #: ###-#### Inspection requested via web by Jim Wellman. 1. 24 houir test passed. 2. The downstream vent must be taken off the upper half of the sewer. see correction notice drawing. 3. Use wye branch fittings on the vent and a drainage fitting on the 90. 4. Add a flammable vapor vent to the tank itself. see diagram provided with the correction notice.
|
PLM17-03141
| Water and/or Sewer | 10/22/2017 | 10/23/2017 | 10/23/2017 9:17:45 AM | A | PASS |
|
|
Hi Dan, Can you please come take a look at my drainage mock up? Consult Thanks, Luke Granden Phone #: ###-#### Inspection requested via web by Becky Granden
|
PLM16-03583
| PLM-Aging Inspection | 10/23/2017 | 10/23/2017 | 10/23/2017 8:11:07 AM | | FAIL |
|
|
This house is for sale. Work has been done without a permit. Builder fails to respond.
|
GRD17-00025
| GRD-Grading Inspection | 10/22/2017 | 10/23/2017 | 10/23/2017 12:00:00 AM | A | CANC |
|
|
SHOULD HAVE BEEN CALLED ON THE PLUMBING PERMIT PLM17-03869 Jim Wellman
Requesting an inspection for 1500 gallon grease interceptor. Not sure what type of inspection is needed. I talked to Dan Ediger Plumbing inspector looked at it and need him to re-inspect tank. Phone #: ###-#### >> Inspection requested via web by Jim Wellman
|