Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM17-04084 Plumbing Rough-in10/23/201710/23/201710/23/2017 4:44:59 PMPPASS
will be ready this afternoon Phone #: ###-#### Inspection requested via web by Troy Paulin
PLM17-03951 Final10/20/201710/23/201710/23/2017 4:25:13 PMPPASS
please call homeowner Pam ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss
PLM17-03903 Final10/23/201710/23/201710/23/2017 3:59:19 PMPPASS
For questions or concerns please call Buck at the number above. Phone #: ###-#### Inspection requested via web by Ben Davis
PLM17-04056 Final10/19/201710/23/201710/23/2017 3:07:48 PMPFAIL
Please inspect the back flow. Please contact Ken Register at ###-#### if you have any questions. Thank you!! Phone #: ###-#### Inspection requested via web by Franz Witte.
Not cerified.. Second trip
PLM17-04005 Final10/19/201710/23/201710/23/2017 2:26:58 PMPPASS
Please call Jackie Coppola at ###-#### prior to inspection - she has dogs. Phone #: ###-#### Inspection requested via web by Mary LaFayette
PLM17-02698 Plumbing Rough-in10/20/201710/23/201710/23/2017 12:33:08 PMAFAIL
Phone #: ###-#### Inspection requested via web by Brian Johansen.
1. The water lines are undersized on the hot and cold sides.
2. Nail plate protect all pipes with proper protection.
3. DWV pressure test failed.
4. The Master bath lav trap arm is too long.
5. Strap all water line sub-outs.
6. Install pipe insulators on the water lines going through studs.
7. Isolate all water lines from concrete.
PLM17-04078 Sprinkler (Final)10/20/201710/23/201710/23/2017 11:48:14 AMAPASS
Phone #: ###-#### Inspection requested via web by Warren Ponder
PLM17-04080 Groundwork10/20/201710/23/201710/23/2017 11:06:17 AMAFAIL
Kevin Phone #: ###-####
1. Pipes are flat and backgrading. Install with a 1/4 per foot grade.
2. Extend the drain outside the house.
3. Wrap all piping in contact with the cement.
PLM17-04082 Plumbing Rough-in10/20/201710/23/201710/23/2017 10:34:09 AMAPASS
Phone #: ###-#### Inspection requested via web by PATTY KIRK
PLM17-03869 Water and/or Sewer10/23/201710/23/201710/23/2017 9:51:36 AMAFAIL
THIS WAS CALLED IN ON THE GRADING PERMIT GRD17-00025 Jim Wellman

Requesting an inspection for 1500 gallon grease interceptor. Not sure what type of inspection is needed. I talked to Dan Ediger Plumbing inspector looked at it and need him to re-inspect tank. Phone #: ###-#### Inspection requested via web by Jim Wellman.
1. 24 houir test passed.
2. The downstream vent must be taken off the upper half of the sewer. see correction notice drawing.
3. Use wye branch fittings on the vent and a drainage fitting on the 90.
4. Add a flammable vapor vent to the tank itself. see diagram provided with the correction notice.
PLM17-03141 Water and/or Sewer10/22/201710/23/201710/23/2017 9:17:45 AMAPASS
Hi Dan,
Can you please come take a look at my drainage mock up?
Consult
Thanks,
Luke Granden Phone #: ###-#### Inspection requested via web by Becky Granden
PLM16-03583 PLM-Aging Inspection10/23/201710/23/201710/23/2017 8:11:07 AM FAIL
This house is for sale. Work has been done without a permit. Builder fails to respond.
GRD17-00025 GRD-Grading Inspection10/22/201710/23/201710/23/2017 12:00:00 AMACANC
SHOULD HAVE BEEN CALLED ON THE PLUMBING PERMIT PLM17-03869 Jim Wellman

Requesting an inspection for 1500 gallon grease interceptor. Not sure what type of inspection is needed. I talked to Dan Ediger Plumbing inspector looked at it and need him to re-inspect tank. Phone #: ###-#### >> Inspection requested via web by Jim Wellman