ELE19-03829
| Electrical Rough-In | 10/23/2019 | 10/23/2019 | 10/23/2019 3:04:47 PM | P | PASS |
|
|
Underground rough-in inspection Contact Shawn Evins Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek 13 parallel service entrance conduits from Idaho transformer to vault then under building to electrical room rough in ok cover.
|
ELE19-00601
| Electrical Rough-In | 10/23/2019 | 10/23/2019 | 10/23/2019 2:24:17 PM | P | PASS |
|
|
Cover for hotel stairway shear wall. Danny is the contact. Phone #: ###-#### Inspection requested via web by Buster Bowen Discussed type of interior raceway for parking garage. With in 10' of exterior edge of garage shall be concidered wet location. All interior areas inside this 10' measurement shall be a dry location as per previous jobs thru-out city. Level 3 hotel stair wall south east corner rough in ok cover.
|
ELE19-04077
| Temporary Service | 10/23/2019 | 10/23/2019 | 10/23/2019 1:52:53 PM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Kerri Hamilton Inspection cancelled from web by: Kerri Hamilton
|
ELE19-03469
| Electrical Rough-In | 10/23/2019 | 10/23/2019 | 10/23/2019 1:52:25 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Complete grid rough in ok cover.
|
ELE19-04026
| Electrical Rough-In | 10/23/2019 | 10/23/2019 | 10/23/2019 1:14:56 PM | P | PASS |
|
|
We will be onsite with all equipment. Phone #: ###-#### Inspection requested via web by Jesse Simpson Listings and scope of work OK. Rough in ok
|
ELE19-03454
| Electrical Rough-In | 10/22/2019 | 10/23/2019 | 10/23/2019 11:29:44 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Laurie Hoelscher Relayed thru permit tech Gemma, Brittney approved inspection OK to perform on monument sign. Listing confirmed rough in ok
|
ELE19-04084
| Electrical Rough-In | 10/22/2019 | 10/23/2019 | 10/23/2019 11:02:11 AM | A | PASS |
|
|
please call prior to arrival for access. Phone #: ###-#### Inspection requested via web by Patrick Paz Master bed and bath rough in ok cover
|
ELE19-04040
| Electrical Rough-In | 10/21/2019 | 10/23/2019 | 10/23/2019 10:37:32 AM | A | PASS |
|
|
Building contractor Anthony will give access. His number is ###-#### For questions call Jerry ###-#### Phone #: ###-#### Inspection requested via web by Dave Brueggemann Kitchen remodel rough in ok cover.
|
ELE19-03844
| Permanent Service | 10/22/2019 | 10/23/2019 | 10/23/2019 10:06:44 AM | A | PASS |
|
|
door code 6290 Phone #: ###-#### Inspection requested via web by Greg Idsinga Range wire has been removed from breaker and has been cut off at the entrance to panel. p/s o/h rec ok
|
ELE19-04082
| Rough-In Permanent Service | 10/22/2019 | 10/23/2019 | 10/23/2019 9:27:56 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Neal Rumsey Attic boxes not trimmed at rough in time of inspection. Rough in ok cover p/s u/g n ok
|
ELE19-03224
| Final | 10/22/2019 | 10/23/2019 | 10/23/2019 9:26:37 AM | A | FAIL |
|
|
garage code 3484 Phone #: ###-#### Inspection requested via web by Neal Rumsey 314.25- All boxes shall be covered. Up hall closet light box open, no light or blank.
|