ELE02-01289
| Final | 10/23/2002 | 10/24/2002 | 10/24/2002 12:00:00 AM | A | FAIL |
|
|
fn steve- ###-####- gar code is 0784
314.20 In Wall or Ceiling.
In walls and ceilings constructed of wood or other combustible surface material, boxes shall be flush with the finished surface or project therefrom.
210.52 Dwelling Unit Receptacle Outlets.
(A) General Provisions. In every kitchen, family room, dining room, living room, parlor, library, den, sunroom, bedroom, recreation room, or similar room or area of dwelling units, receptacle outlets shall be installed in accordance with the general provisions specified in 210.52(A)(1) through (A)(3).
(C) Countertops. In kitchens and dining rooms of dwelling units, receptacle outlets for counter spaces shall be installed in accordance with 210.52(C)(1) through (5).
406.8 Receptacles in Damp or Wet Locations.
(B) Wet Locations.
(1) 15- and 20-Ampere Outdoor Receptacles. 15- and 20-ampere, 125- and 250-volt receptacles installed outdoors in a wet location shall have an enclosure that is weatherproof whether or not the attachment plug cap is inserted.
348.12 Uses Not Permitted.
FMC shall not be used in the following:
(6) Underground or embedded in poured concrete or aggregate
300.15 Boxes, Conduit Bodies, or Fittings - Where Required.
Where the wiring method is conduit, tubing, Type AC cable, Type MC cable, Type MI cable, nonmetallic-sheathed cable, or other cables, a box or conduit body complying with Article 314 shall be installed at each conductor splice point,
10/24/2002 10:08:46 AM
|
ELE02-01022
| Electrical Rough-In | 10/23/2002 | 10/24/2002 | 10/24/2002 12:00:00 AM | A | NR |
|
|
SHAWN ###-#### CONF ONLY
|
ELE01-03966
| Final | 10/23/2002 | 10/24/2002 | 10/24/2002 12:00:00 AM | A | DONE |
|
|
PAT THIS WAS FINALED 3-15-02 SO IT JUST NEEDS TO HAVE A DOC FINAL
|
ELE02-02752
| Final | 10/23/2002 | 10/24/2002 | 10/24/2002 12:00:00 AM | A | PASS |
|
|
###-####
|
ELE02-02880
| Electrical Rough-In | 10/24/2002 | 10/24/2002 | 10/24/2002 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 10/24/2002 at 08:20:05. Contact: ###-####.
|
ELE02-02839
| Permanent Service | 10/24/2002 | 10/24/2002 | 10/24/2002 12:00:00 AM | P | PART |
|
|
###-#### Jeff
P/S U/G R Ok 10/24/2002 2:26:36 PM
|
ELE02-03317
| Electrical Rough-In | 10/24/2002 | 10/24/2002 | 10/24/2002 12:00:00 AM | P | PASS |
|
|
KATHY ###-####
pool bobd ok 10/24/2002 4:37:06 PM
|
ELE02-03300
| Permanent Service | 10/24/2002 | 10/24/2002 | 10/24/2002 12:00:00 AM | P | PASS |
|
|
###-####
P/S U/G R OK 10/24/2002 1:50:33 PM
|
ELE02-01374
| Final | 10/24/2002 | 10/24/2002 | 10/24/2002 12:00:00 AM | P | PASS |
|
|
tom key in storage box by front door-code 1960; Phone #: ###-#### final on 1375 and 1371
|
ELE02-03105
| Electrical Rough-In | 10/23/2002 | 10/24/2002 | 10/24/2002 12:00:00 AM | P | NR |
|
|
Scheduled by a contractor via Hello! on 10/23/2002 at 08:58:04. Contact: ###-####.
No work done yet and address is way off 10/24/2002 1:14:50 PM
|